These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 18356648)

  • 21. Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve design.
    Leo HL; He Z; Ellis JT; Yoganathan AP
    J Thorac Cardiovasc Surg; 2002 Sep; 124(3):561-74. PubMed ID: 12202873
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Closing behavior of the mechanical heart valve in a total artificial heart.
    Lee HS; Tsukiya T; Homma A; Taenaka Y; Tatsumi E; Takano H
    J Artif Organs; 2003; 6(1):37-41. PubMed ID: 14598123
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Closing behavior of a new bileaflet mechanical heart valve.
    Bluestein D; Menon S; Wu ZJ; Haubold A; Armitage TL; Hwang NH
    ASAIO J; 1993; 39(3):M398-402. PubMed ID: 8268566
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Occluder closing behavior: a key factor in mechanical heart valve cavitation.
    Wu ZJ; Wang Y; Hwang NH
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S25-33; discussion S33-4. PubMed ID: 8061868
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Computational fluid dynamics study of a protruded-hinge bileaflet mechanical heart valve.
    Wang J; Yao H; Lim CJ; Zhao Y; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2001 Mar; 10(2):254-262; discussion 263. PubMed ID: 11297213
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Mechanical valve closing dynamics: relationship between velocity of closing, pressure transients, and cavitation initiation.
    Chandran KB; Aluri S
    Ann Biomed Eng; 1997; 25(6):926-38. PubMed ID: 9395039
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Pressure field in the vicinity of mechanical valve occluders at the instant of valve closure: correlation with cavitation initiation.
    Chandran KB; Lee CS; Chen LD
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S65-75; discussion S75-6. PubMed ID: 8061871
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An experimental-computational analysis of MHV cavitation: effects of leaflet squeezing and rebound.
    Makhijani VB; Yang HQ; Singhal AK; Hwang NH
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S35-44; discussion S44-8. PubMed ID: 8061869
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Three-dimensional flow analysis of a mechanical bileaflet mitral prosthesis.
    Akutsu T; Masuda T
    J Artif Organs; 2003; 6(2):112-23. PubMed ID: 14598112
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of hinge gap width on the microflow structures in 27-mm bileaflet mechanical heart valves.
    Leo HL; Simon HA; Dasi LP; Yoganathan AP
    J Heart Valve Dis; 2006 Nov; 15(6):800-8. PubMed ID: 17152788
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of systolic duration on mechanical heart valve cavitation in a pneumatic ventricular assist device: using a monoleaflet valve.
    Lee H; Tatsumi E; Taenaka Y
    ASAIO J; 2008; 54(1):25-30. PubMed ID: 18204312
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Relative blood damage in the three phases of a prosthetic heart valve flow cycle.
    Lamson TC; Rosenberg G; Geselowitz DB; Deutsch S; Stinebring DR; Frangos JA; Tarbell JM
    ASAIO J; 1993; 39(3):M626-33. PubMed ID: 8268614
    [TBL] [Abstract][Full Text] [Related]  

  • 33. An in-vitro investigation of prosthetic heart valve cavitation in blood.
    Garrison LA; Lamson TC; Deutsch S; Geselowitz DB; Gaumond RP; Tarbell JM
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S8-22; discussion S22-4. PubMed ID: 8061873
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Digital particle image velocimetry (DPIV) measurements of the velocity profiles through bileaflet mechanical valves: in vitro steady.
    Shandas R; Kwon J
    Biomed Sci Instrum; 1996; 32():161-7. PubMed ID: 8672664
    [TBL] [Abstract][Full Text] [Related]  

  • 35. An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flow.
    Saxena R; Lemmon J; Ellis J; Yoganathan A
    J Thorac Cardiovasc Surg; 2003 Jul; 126(1):90-8. PubMed ID: 12878943
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Flow characterization of the ADVANTAGE and St. Jude Medical bileaflet mechanical heart valves.
    Shu MC; O'Rourke KK; Coppin CM; Lemmon JD
    J Heart Valve Dis; 2004 Sep; 13(5):814-22. PubMed ID: 15473485
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Mechanical heart valve cavitation.
    Johansen P
    Expert Rev Med Devices; 2004 Sep; 1(1):95-104. PubMed ID: 16293013
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Estimation of mechanical heart valve cavitation in an electro-hydraulic total artificial heart.
    Lee H; Taenaka Y; Kitamura S
    Artif Organs; 2006 Jan; 30(1):16-23. PubMed ID: 16409393
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Leakage flow at mechanical heart valve prostheses: improved washout or increased blood damage?
    Steegers A; Paul R; Reul H; Rau G
    J Heart Valve Dis; 1999 May; 8(3):312-23. PubMed ID: 10399668
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cavitation phenomenon in monoleaflet mechanical heart valves with electrohydraulic total artificial heart.
    Lee H; Taenaka Y; Kitamura S
    Int J Artif Organs; 2004 Sep; 27(9):779-86. PubMed ID: 15521218
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.