  • 41. The use of enzyme activated milk for in vitro simulation of prosthetic valve thrombosis.
    Keggen LA; Black MM; Lawford PV; Hose DR; Strachan JR
    J Heart Valve Dis; 1996 Jan; 5(1):74-83. PubMed ID: 8834729
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Statistical characteristics of mechanical heart valve cavitation in accelerated testing.
    Wu C; Hwang NH; Lin YK
    J Heart Valve Dis; 2004 Jul; 13(4):659-66. PubMed ID: 15311875
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Modifying a tilting disk mechanical heart valve design to improve closing dynamics.
    Herbertson LH; Deutsch S; Manning KB
    J Biomech Eng; 2008 Oct; 130(5):054503. PubMed ID: 19045527
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.
    Dumont K; Vierendeels J; Kaminsky R; van Nooten G; Verdonck P; Bluestein D
    J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Numerical dye washout method as a tool for characterizing the heart valve flow: study of three standard mechanical heart valves.
    Goubergrits L; Kertzscher U; Affeld K; Petz C; Stalling D; Hege HC
    ASAIO J; 2008; 54(1):50-7. PubMed ID: 18204316
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Fluid dynamic assessment of three polymeric heart valves using particle image velocimetry.
    Leo HL; Dasi LP; Carberry J; Simon HA; Yoganathan AP
    Ann Biomed Eng; 2006 Jun; 34(6):936-52. PubMed ID: 16783650
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing.
    Lee H; Homma A; Tatsumi E; Taenaka Y
    J Artif Organs; 2010 Apr; 13(1):17-23. PubMed ID: 20155293
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Mechanism for cavitation of monoleaflet and bileaflet valves in an artificial heart.
    Lee H; Tatsumi E; Homma A; Tsukiya T; Taenaka Y
    J Artif Organs; 2006; 9(3):154-60. PubMed ID: 16998700
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Wavelet transforms in the analysis of mechanical heart valve cavitation.
    Herbertson LH; Reddy V; Manning KB; Welz JP; Fontaine AA; Deutsch S
    J Biomech Eng; 2006 Apr; 128(2):217-22. PubMed ID: 16524333
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Laser Doppler velocimetry and flow visualization studies in the regurgitant leakage flow region of three mechanical mitral valves.
    Meyer RS; Deutsch S; Bachmann CB; Tarbell JM
    Artif Organs; 2001 Apr; 25(4):292-9. PubMed ID: 11318758
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Bubble observation and transient pressure signals in mechanical heart valve cavitation study.
    Lijun X; Hock YJ; Hwang NH
    J Heart Valve Dis; 2003 Mar; 12(2):235-44. PubMed ID: 12701797
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Hemodynamics of high-performance bileaflet valves: comparison to simulated clinical Doppler measurements.
    Dohmen G; Schmitz C; Schmitz-Rode T; Steinseifer U; Autschbach R
    J Heart Valve Dis; 2006 Jul; 15(4):549-56. PubMed ID: 16901053
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Effects of the driving condition of a pneumatic ventricular assist device on the cavitation intensity of the inlet and outlet mechanical heart valves.
    Lee H; Tatsumi E; Taenaka Y
    ASAIO J; 2009; 55(4):328-34. PubMed ID: 19506466
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Spatio-temporal flow analysis in bileaflet heart valve hinge regions: potential analysis for blood element damage.
    Simon HA; Dasi LP; Leo HL; Yoganathan AP
    Ann Biomed Eng; 2007 Aug; 35(8):1333-46. PubMed ID: 17431789
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Comparative in vitro study of bileaflet and tilting disk valve behavior in the pulmonary position.
    Gohean J; Figliola R; Camp T; McQuinn T
    J Biomech Eng; 2006 Aug; 128(4):631-5. PubMed ID: 16813455
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model.
    He Z; Xi B; Zhu K; Hwang NH
    J Heart Valve Dis; 2001 Sep; 10(5):666-74. PubMed ID: 11603607
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Study of an acoustic technique to detect cavitation produced by a tilting disc valve.
    Herman BA; Porter JM; Carey RF
    J Heart Valve Dis; 1996 Jan; 5(1):90-6. PubMed ID: 8834731
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A novel pulse duplicator system: evaluation of different valve prostheses.
    Haaf P; Steiner M; Attmann T; Pfister G; Cremer J; Lutter G
    Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Experimental study on the Reynolds and viscous shear stress of bileaflet mechanical heart valves in a pneumatic ventricular assist device.
    Lee H; Tatsumi E; Taenaka Y
    ASAIO J; 2009; 55(4):348-54. PubMed ID: 19521236
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A microstructural flow analysis within a bileaflet mechanical heart valve hinge.
    Gross JM; Shu MC; Dai FF; Ellis J; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):581-90. PubMed ID: 8953435
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]