BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

84 related articles for article (PubMed ID: 18358396)

  • 1. "A randomized clinical trial of cementless femoral stems with and without hydroxyapatite/tricalcium-phosphate coating: an 8- to 12-year follow-up study" by Yoon et al.
    Hernandez-Vaquero D; Fernandez-Carreira JM; Garcia-Sandoval MA
    J Arthroplasty; 2008 Apr; 23(3):486-7; author reply 487. PubMed ID: 18358396
    [No Abstract]   [Full Text] [Related]  

  • 2. A randomized clinical trial of cementless femoral stems with and without hydroxyapatite/tricalcium-phosphate coating: an 8- to 12-year follow-up study.
    Yoon KS; Kim HJ; Lee JH; Kang SB; Seong NH; Koo KH
    J Arthroplasty; 2007 Jun; 22(4):504-8. PubMed ID: 17562405
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Femoral remodeling after porous-coated total hip arthroplasty with and without hydroxyapatite-tricalcium phosphate coating: a prospective randomized trial.
    Tanzer M; Kantor S; Rosenthall L; Bobyn JD
    J Arthroplasty; 2001 Aug; 16(5):552-8. PubMed ID: 11503113
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration].
    Landor I; Vavrík P; Jahoda D; Pokorný D; Ballay R; Sosna A
    Acta Chir Orthop Traumatol Cech; 2009 Jun; 76(3):172-8. PubMed ID: 19595277
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty.
    Chambers B; St Clair SF; Froimson MI
    J Arthroplasty; 2007 Jun; 22(4 Suppl 1):71-4. PubMed ID: 17570282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. HA particles can be released from well-fixed HA-coated stems.
    Tonino AJ
    Acta Orthop Scand; 2003 Jun; 74(3):365; author reply 366-8. PubMed ID: 12899560
    [No Abstract]   [Full Text] [Related]  

  • 7. Comparison of Hydroxyapatite-coated stems in total hip arthroplasty after a minimum 10-years follow-up.
    Gallo J; Landor I; Cechová I; Jahoda D
    Acta Chir Orthop Traumatol Cech; 2008 Oct; 75(5):339-46. PubMed ID: 19026187
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tapered hydroxyapatite-coated press-fit stems: any added value?
    Rorabeck CH
    J Arthroplasty; 2006 Jun; 21(4 Suppl 1):85-8. PubMed ID: 16781437
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hydroxyapatite-coated prostheses in total hip and knee arthroplasty.
    Dumbleton J; Manley MT
    J Bone Joint Surg Am; 2004 Nov; 86(11):2526-40. PubMed ID: 15523030
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cementless porous-coated anatomic total hip arthroplasty at Duke: 18- to 24-year follow-up.
    Ferrell MS; Browne JA; Attarian DE; Cook C; Bolognesi MP
    J Surg Orthop Adv; 2009; 18(3):150-4. PubMed ID: 19843441
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical results from the calcitite-coated press fit APR hip system.
    Dorr LD; Smith C
    Dent Clin North Am; 1992 Jan; 36(1):239-46. PubMed ID: 1310656
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hydroxyapatite coated femoral stems in primary total hip arthroplasty: a meta-analysis.
    Gandhi R; Davey JR; Mahomed NN
    J Arthroplasty; 2009 Jan; 24(1):38-42. PubMed ID: 18534435
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The removal of cementless total hip femoral components.
    Glassman AH
    Instr Course Lect; 2002; 51():93-101. PubMed ID: 12064152
    [No Abstract]   [Full Text] [Related]  

  • 14. Hydroxyapatite-coated versus grit-blasted femoral stems.
    Amstutz HC
    J Bone Joint Surg Br; 2002 Nov; 84(8):1206-7; author reply 1207. PubMed ID: 12463673
    [No Abstract]   [Full Text] [Related]  

  • 15. Influence of stem size on clinical outcome of primary total hip arthroplasty with cementless extensively porous-coated femoral components.
    Engh CA; Mohan V; Nagowski JP; Sychterz Terefenko CJ; Engh CA
    J Arthroplasty; 2009 Jun; 24(4):554-9. PubMed ID: 18534449
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Longitudinal and axial stability of a cementless metaphyseal versus a fully porous coated cylindrical femoral stem.
    Rivera VR; Parks BG; Boucher HR
    J Surg Orthop Adv; 2009; 18(2):99-102. PubMed ID: 19602338
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hydroxyapatite-coated orthopedic implants.
    Dunn MG; Maxian SH
    J Long Term Eff Med Implants; 1991; 1(2):193-203. PubMed ID: 10171112
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hydroxyapatite-coated total hip arthroplasty: the impact on thigh pain and arthroplasty survival.
    Baltopoulos P; Tsintzos C; Papadakou E; Karagounis P; Tsironi M
    Acta Orthop Belg; 2008 Jun; 74(3):323-31. PubMed ID: 18686456
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up.
    Zwartelé RE; Olsthoorn PG; Pöll RG; Brand R; Doets HC
    Arch Orthop Trauma Surg; 2008 Dec; 128(12):1379-86. PubMed ID: 18758793
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Clinical analysis and prevention from coating shedding of uncemented hip prosthesis].
    Wang F; Chen DY; Qiu XS; Xu ZH; Wang ZY; Shi DQ; Jiang Q
    Zhongguo Gu Shang; 2009 Jun; 22(6):413-6. PubMed ID: 19594034
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.