These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 18358755)

  • 1. Theoretical prediction and experimental measurement of the field dependence of the apparent transverse relaxation of hyperpolarized noble gases in lungs.
    Parra-Robles J; Dominguez Viqueira W; Xu X; Ouriadov A; Santyr GE
    J Magn Reson; 2008 May; 192(1):85-91. PubMed ID: 18358755
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs.
    Parra-Robles J; Cross AR; Santyr GE
    Med Phys; 2005 Jan; 32(1):221-9. PubMed ID: 15719973
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Signal dynamics in magnetic resonance imaging of the lung with hyperpolarized noble gases.
    Möller HE; Chen XJ; Chawla MS; Driehuys B; Hedlund LW; Johnson GA
    J Magn Reson; 1998 Nov; 135(1):133-43. PubMed ID: 9799687
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Passive shimming of the fringe field of a superconducting magnet for ultra-low field hyperpolarized noble gas MRI.
    Parra-Robles J; Cross AR; Santyr GE
    J Magn Reson; 2005 May; 174(1):116-24. PubMed ID: 15809179
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Imaging of a mixture of hyperpolarized 3He and 129Xe.
    Acosta RH; Blümler P; Han S; Appelt S; Häsing FW; Schmiedeskamp J; Heil W; Spiess HW
    Magn Reson Imaging; 2004 Oct; 22(8):1077-83. PubMed ID: 15527994
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Gradient-echo imaging considerations for hyperpolarized 129Xe MR.
    Zhao L; Mulkern R; Tseng CH; Williamson D; Patz S; Kraft R; Walsworth RL; Jolesz FA; Albert MS
    J Magn Reson B; 1996; 113():179-83. PubMed ID: 11543610
    [No Abstract]   [Full Text] [Related]  

  • 7. Magnetic resonance imaging of dissolved hyperpolarized 129Xe using a membrane-based continuous flow system.
    Amor N; Zänker PP; Blümler P; Meise FM; Schreiber LM; Scholz A; Schmiedeskamp J; Spiess HW; Münnemann K
    J Magn Reson; 2009 Nov; 201(1):93-9. PubMed ID: 19729327
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a hyperpolarized 129Xe system on 3T for the rat lungs.
    Sato H; Enmi J; Hayashi T; Takei N; Iwadate Y; Abe S; Teramoto N; Kawachi N; Hattori M; Watabe H; Sawada T; Uchiyama K; Tsukamoto T; Nagasawa K; Iida H
    Magn Reson Med Sci; 2004 Apr; 3(1):1-9. PubMed ID: 16093614
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dependence of transverse relaxation time T2 of biologic tissues on the interpulse delay time in Carr-Purcell-Meiboom-Gill (CPMG) measurements.
    Shioya S; Kurita D; Haida M; Fukuzaki M; Tanigaki T; Kutsuzawa T; Ohta Y
    Tokai J Exp Clin Med; 1997 May; 22(2):27-31. PubMed ID: 9608628
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Susceptibility effects in hyperpolarized (3)He lung MRI at 1.5T and 3T.
    Deppe MH; Parra-Robles J; Ajraoui S; Parnell SR; Clemence M; Schulte RF; Wild JM
    J Magn Reson Imaging; 2009 Aug; 30(2):418-23. PubMed ID: 19629971
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Longitudinal relaxation and diffusion measurements using magnetic resonance signals from laser-hyperpolarized 129Xe nuclei.
    Patyal BR; Gao JH; Williams RF; Roby J; Saam B; Rockwell BA; Thomas RJ; Stolarski DJ; Fox PT
    J Magn Reson; 1997 May; 126(1):58-65. PubMed ID: 9177796
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of alveolar oxygen partial pressure in the rat lung using Carr-Purcell-Meiboom-Gill spin-spin relaxation times of hyperpolarized 3He and 129Xe at 74 mT.
    Kraayvanger RJ; Bidinosti CP; Dominguez-Viqueira W; Parra-Robles J; Fox M; Lam WW; Santyr GE
    Magn Reson Med; 2010 Nov; 64(5):1484-90. PubMed ID: 20593371
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Boundary element model for simulating sound propagation and source localization within the lungs.
    Ozer MB; Acikgoz S; Royston TJ; Mansy HA; Sandler RH
    J Acoust Soc Am; 2007 Jul; 122(1):657-61. PubMed ID: 17614522
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diffusion-weighted 19F-MRI of lung periphery: Influence of pressure and air-SF6 composition on apparent diffusion coefficients.
    Ruiz-Cabello J; Pérez-Sánchez JM; Pérez de Alejo R; Rodríguez I; González-Mangado N; Peces-Barba G; Cortijo M
    Respir Physiol Neurobiol; 2005 Aug; 148(1-2):43-56. PubMed ID: 16098469
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hyperpolarized 83Kr MRI of lungs.
    Cleveland ZI; Pavlovskaya GE; Elkins ND; Stupic KF; Repine JE; Meersmann T
    J Magn Reson; 2008 Dec; 195(2):232-7. PubMed ID: 18948043
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hyperpolarized 83Kr and 129Xe NMR relaxation measurements of hydrated surfaces: implications for materials science and pulmonary diagnostics.
    Cleveland ZI; Stupic KF; Pavlovskaya GE; Repine JE; Wooten JB; Meersmann T
    J Am Chem Soc; 2007 Feb; 129(6):1784-92. PubMed ID: 17243679
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Signal-to-noise ratio for hyperpolarized ³He MR imaging of human lungs: a 1.5 T and 3 T comparison.
    Dominguez-Viqueira W; Ouriadov A; O'Halloran R; Fain SB; Santyr GE
    Magn Reson Med; 2011 Nov; 66(5):1400-4. PubMed ID: 21523821
    [TBL] [Abstract][Full Text] [Related]  

  • 18. T2-shortening of 3He gas by magnetic microspheres.
    Minard KR; Timchalk C; Corley RA
    J Magn Reson; 2005 Mar; 173(1):90-6. PubMed ID: 15705517
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A system for low field imaging of laser-polarized noble gas.
    Wong GP; Tseng CH; Pomeroy VR; Mair RW; Hinton DP; Hoffmann D; Stoner RE; Hersman FW; Cory DG; Walsworth RL
    J Magn Reson; 1999 Dec; 141(2):217-27. PubMed ID: 10579945
    [TBL] [Abstract][Full Text] [Related]  

  • 20. T2, Carr-Purcell T2 and T1rho of fat and water as surrogate markers of trabecular bone structure.
    Lammentausta E; Silvast TS; Närväinen J; Jurvelin JS; Nieminen MT; Gröhn OH
    Phys Med Biol; 2008 Feb; 53(3):543-55. PubMed ID: 18199901
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.