These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
95 related articles for article (PubMed ID: 1836203)
21. The use of biomaterials in the repair of abdominal wall defects: a comparative study between polypropylene meshes (Marlex) and a new polytetrafluoroethylene prosthesis (Dual Mesh). Bellón JM; Contreras LA; Buján J; Carrera-San Martín A J Biomater Appl; 1997 Oct; 12(2):121-35. PubMed ID: 9399138 [TBL] [Abstract][Full Text] [Related]
22. Evaluation of implant/host tissue interactions following intraperitoneal implantation of porcine dermal collagen prosthesis in the rat. Kaleya RN Hernia; 2005 Oct; 9(3):269-76. PubMed ID: 16136391 [TBL] [Abstract][Full Text] [Related]
23. Foreign-body reaction to dermal sheep collagen in interferon-gamma-receptor knock-out mice. Khouw IM; van Wachem PB; Plantinga JA; Haagmans BL; de Leij LF; van Luyn MJ J Biomed Mater Res; 2000 May; 50(2):259-66. PubMed ID: 10679691 [TBL] [Abstract][Full Text] [Related]
24. Double-layer prostheses for repair of abdominal wall defects in a rabbit model. Walker AP; Henderson J; Condon RE J Surg Res; 1993 Jul; 55(1):32-7. PubMed ID: 8412079 [TBL] [Abstract][Full Text] [Related]
25. Comparison of prosthetic materials used for abdominal wall defects or hernias (an experimental study). Sahin M; Hasanoğlu A; Erbilen M; Orakçi V; Bülbüloğlu E; Ertaş E Acta Chir Hung; 1995-1996; 35(3-4):291-5. PubMed ID: 9262726 [TBL] [Abstract][Full Text] [Related]
26. Experimental evaluation of a new composite mesh with the selective property of incorporation to the abdominal wall without adhering to the intestines. Amid PK; Shulman AG; Lichtenstein IL; Sostrin S; Young J; Hakakha M J Biomed Mater Res; 1994 Mar; 28(3):373-5. PubMed ID: 8077252 [TBL] [Abstract][Full Text] [Related]
27. Morphologic study of three collagen materials for body wall repair. Soiderer EE; Lantz GC; Kazacos EA; Hodde JP; Wiegand RE J Surg Res; 2004 May; 118(2):161-75. PubMed ID: 15100005 [TBL] [Abstract][Full Text] [Related]
28. Inhibition of the tissue reaction to a biodegradable biomaterial by monoclonal antibodies to IFN-gamma. Khouw IM; van Wachem PB; de Leij LF; van Luyn MJ J Biomed Mater Res; 1998 Aug; 41(2):202-10. PubMed ID: 9638524 [TBL] [Abstract][Full Text] [Related]
29. Healing effect of acellular dermal matrixes for repair of abdominal wall defects in a rat model. Kim JM; Choi SH In Vivo; 2013; 27(6):755-60. PubMed ID: 24292579 [TBL] [Abstract][Full Text] [Related]
30. Evaluation of a collagen-based biosynthetic material for the repair of abdominal wall defects. Werkmeister JA; Edwards GA; Casagranda F; White JF; Ramshaw JA J Biomed Mater Res; 1998 Mar; 39(3):429-36. PubMed ID: 9468052 [TBL] [Abstract][Full Text] [Related]
31. Use of carbon fibers for repair of abdominal-wall defects in rats. Morris DM; Haskins R; Marino AA; Misra RP; Rogers S; Fronczak S; Albright JA Surgery; 1990 Jun; 107(6):627-31. PubMed ID: 2141192 [TBL] [Abstract][Full Text] [Related]
32. Reherniation after repair of the abdominal wall with expanded polytetrafluoroethylene. Simmermacher RK; Schakenraad JM; Bleichrodt RP J Am Coll Surg; 1994 Jun; 178(6):613-6. PubMed ID: 8193756 [TBL] [Abstract][Full Text] [Related]
33. Tensile strength and host response towards silk and type i polypropylene implants used for augmentation of fascial repair in a rat model. Spelzini F; Konstantinovic ML; Guelinckx I; Verbist G; Verbeken E; De Ridder D; Deprest J Gynecol Obstet Invest; 2007; 63(3):155-62. PubMed ID: 17095874 [TBL] [Abstract][Full Text] [Related]
35. Expanded polytetrafluoroethylene patch versus polypropylene mesh for the repair of contaminated defects of the abdominal wall. Bleichrodt RP; Simmermacher RK; van der Lei B; Schakenraad JM Surg Gynecol Obstet; 1993 Jan; 176(1):18-24. PubMed ID: 8427001 [TBL] [Abstract][Full Text] [Related]
36. [Can we define "histological tolerance" of the abdominal wall after the implantation of various prosthetic materials?]. Arnaud JP; Eloy R; Aprahamian M; Adloff M; Grenier JF Acta Chir Belg; 1977; 76(6):575-82. PubMed ID: 145780 [TBL] [Abstract][Full Text] [Related]
37. Implants in the abdominal wall of the rat. Thomsen P; Bjursten LM; Ericson LE Scand J Plast Reconstr Surg; 1986; 20(2):173-82. PubMed ID: 2948276 [TBL] [Abstract][Full Text] [Related]
38. Effect of tanning agent on tissue reaction to tissue implanted collagen sponge. Chvapil M; Speer D; Mora W; Eskelson C J Surg Res; 1983 Nov; 35(5):402-9. PubMed ID: 6415345 [TBL] [Abstract][Full Text] [Related]
39. The behavior of different types of polytetrafluoroethylene (PTFE) prostheses in the reparative scarring process of abdominal wall defects. Buján J; Contreras LA; Carrera-San Martín A; Bellón JM Histol Histopathol; 1997 Jul; 12(3):683-90. PubMed ID: 9225151 [TBL] [Abstract][Full Text] [Related]
40. Small intestinal submucosa: utilization for repair of rodent abdominal wall defects. Prevel CD; Eppley BL; Summerlin DJ; Jackson JR; McCarty M; Badylak SF Ann Plast Surg; 1995 Oct; 35(4):374-80. PubMed ID: 8585680 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]