These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
368 related articles for article (PubMed ID: 18367200)
1. Time domain parameters can be estimated with less statistical error than frequency domain parameters in the analysis of heart rate variability. Kuss O; Schumann B; Kluttig A; Greiser KH; Haerting J J Electrocardiol; 2008; 41(4):287-91. PubMed ID: 18367200 [TBL] [Abstract][Full Text] [Related]
2. Estimation of HRV spectrogram using multiple window methods focussing on the high frequency power. Hansson M; Jönsson P Med Eng Phys; 2006 Oct; 28(8):749-61. PubMed ID: 16443384 [TBL] [Abstract][Full Text] [Related]
3. Sampling frequency of the RR interval time series for spectral analysis of heart rate variability. Singh D; Vinod K; Saxena SC J Med Eng Technol; 2004; 28(6):263-72. PubMed ID: 15513744 [TBL] [Abstract][Full Text] [Related]
4. Time-varying analysis of heart rate variability signals with a Kalman smoother algorithm. Tarvainen MP; Georgiadis SD; Ranta-Aho PO; Karjalainen PA Physiol Meas; 2006 Mar; 27(3):225-39. PubMed ID: 16462010 [TBL] [Abstract][Full Text] [Related]
5. QT variability and HRV interactions in ECG: quantification and reliability. Almeida R; Gouveia S; Rocha AP; Pueyo E; Martínez JP; Laguna P IEEE Trans Biomed Eng; 2006 Jul; 53(7):1317-29. PubMed ID: 16830936 [TBL] [Abstract][Full Text] [Related]
6. Sometimes higher heart rate variability is not better heart rate variability: results of graphical and nonlinear analyses. Stein PK; Domitrovich PP; Hui N; Rautaharju P; Gottdiener J J Cardiovasc Electrophysiol; 2005 Sep; 16(9):954-9. PubMed ID: 16174015 [TBL] [Abstract][Full Text] [Related]
7. Quantifying errors in spectral estimates of HRV due to beat replacement and resampling. Clifford GD; Tarassenko L IEEE Trans Biomed Eng; 2005 Apr; 52(4):630-8. PubMed ID: 15825865 [TBL] [Abstract][Full Text] [Related]
8. Assessment of heart rate variability during alterations in stress: complex demodulation vs. spectral analysis. Wilhelm FH; Grossman P; Roth WT Biomed Sci Instrum; 2005; 41():346-51. PubMed ID: 15850130 [TBL] [Abstract][Full Text] [Related]
9. Comparison of the ratio of the standard deviation of the R-R interval and the root mean squared successive differences (SD/rMSSD) to the low frequency-to-high frequency (LF/HF) ratio in a patient population and normal healthy controls. Sollers JJ; Buchanan TW; Mowrer SM; Hill LK; Thayer JF Biomed Sci Instrum; 2007; 43():158-63. PubMed ID: 17487074 [TBL] [Abstract][Full Text] [Related]
10. Renyi entropy measures of heart rate Gaussianity. Lake DE IEEE Trans Biomed Eng; 2006 Jan; 53(1):21-7. PubMed ID: 16402599 [TBL] [Abstract][Full Text] [Related]
11. Investigation of the effects of ischemic preconditioning on the HRV response to transient global ischemia using linear and nonlinear methods. Moraru L; Tong S; Malhotra A; Geocadin R; Thakor N; Bezerianos A Med Eng Phys; 2005 Jul; 27(6):465-73. PubMed ID: 15990063 [TBL] [Abstract][Full Text] [Related]
12. Parametric evaluation of heart rate variability during the menstrual cycle in young women. Princi T; Parco S; Accardo A; Radillo O; De Seta F; Guaschino S Biomed Sci Instrum; 2005; 41():340-5. PubMed ID: 15850129 [TBL] [Abstract][Full Text] [Related]
13. Heart rate variability on 7-day Holter monitoring using a bootstrap rhythmometric procedure. Goya-Esteban R; Mora-Jiménez I; Rojo-Alvarez JL; Barquero-Pérez O; Pastor-Pérez FJ; Manzano-Fernández S; Pascual-Figal DA; García-Alberola A IEEE Trans Biomed Eng; 2010 Jun; 57(6):1366-76. PubMed ID: 20172786 [TBL] [Abstract][Full Text] [Related]
14. Orthonormal-basis partitioning and time-frequency representation of cardiac rhythm dynamics. Aysin B; Chaparro LF; Gravé I; Shusterman V IEEE Trans Biomed Eng; 2005 May; 52(5):878-89. PubMed ID: 15887537 [TBL] [Abstract][Full Text] [Related]
15. Heart rate variability measures: a fresh look at reliability. Pinna GD; Maestri R; Torunski A; Danilowicz-Szymanowicz L; Szwoch M; La Rovere MT; Raczak G Clin Sci (Lond); 2007 Aug; 113(3):131-40. PubMed ID: 17381425 [TBL] [Abstract][Full Text] [Related]
17. Heart rate variability: comparison among devices with different temporal resolutions. Chellakumar PJ; Brumfield A; Kunderu K; Schopper AW Physiol Meas; 2005 Dec; 26(6):979-86. PubMed ID: 16311446 [TBL] [Abstract][Full Text] [Related]
18. Influence of 50 Hz magnetic field on human heart rate variability: linear and nonlinear analysis. Tabor Z; Michalski J; Rokita E Bioelectromagnetics; 2004 Sep; 25(6):474-80. PubMed ID: 15300734 [TBL] [Abstract][Full Text] [Related]
19. Low HRV entropy is strongly associated with myocardial infarction. Lau S; Haueisen J; Schukat-Talamazzini EG; Voss A; Goernig M; Leder U; Figulla HR Biomed Tech (Berl); 2006 Oct; 51(4):186-9. PubMed ID: 17061935 [TBL] [Abstract][Full Text] [Related]
20. The efficiency of 10-second resting heart rate for the evaluation of short-term heart rate variability indices. Nussinovitch U; Elishkevitz KP; Kaminer K; Nussinovitch M; Segev S; Volovitz B; Nussinovitch N Pacing Clin Electrophysiol; 2011 Nov; 34(11):1498-502. PubMed ID: 21797904 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]