These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
629 related articles for article (PubMed ID: 18371758)
1. Novel lipoate-selective membrane sensor for the flow injection determination of alpha-lipoic acid in pharmaceutical preparations and urine. Abbas MN; Radwan AA Talanta; 2008 Feb; 74(5):1113-21. PubMed ID: 18371758 [TBL] [Abstract][Full Text] [Related]
3. Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine. Ensafi AA; Allafchian AR J Pharm Biomed Anal; 2008 Aug; 47(4-5):802-6. PubMed ID: 18448303 [TBL] [Abstract][Full Text] [Related]
4. PVC membrane electrode for the potentiometric determination of Ipratropium bromide using batch and flow injection techniques. Hassouna ME; Elsuccary SA Talanta; 2008 Jun; 75(5):1175-83. PubMed ID: 18585199 [TBL] [Abstract][Full Text] [Related]
5. s-Benzylthiuronium PVC matrix membrane sensor for potentiometric determination of cationic surfactants in some pharmaceutical formulation. Mostafa GA J Pharm Biomed Anal; 2006 Jun; 41(4):1110-5. PubMed ID: 16540278 [TBL] [Abstract][Full Text] [Related]
6. PVC membrane ion-selective electrodes for the determination of Hyoscyamine in pure solution and in pharmaceutical preparations under batch and flow modes. Badawy SS; Issa YM; Mutair AA J Pharm Biomed Anal; 2005 Sep; 39(1-2):117-24. PubMed ID: 15935604 [TBL] [Abstract][Full Text] [Related]
7. A novel flow injection potentiometric graphite coated ion-selective electrode for the low level determination of uranyl ion. Shamsipur M; Mizani F; Mousavi MF; Alizadeh N; Alizadeh K; Eshghi H; Karami H Anal Chim Acta; 2007 Apr; 589(1):22-32. PubMed ID: 17397648 [TBL] [Abstract][Full Text] [Related]
8. Optimization of polymeric triiodide membrane electrode based on clozapine-triiodide ion-pair using experimental design. Farhadi K; Bahram M; Shokatynia D; Salehiyan F Talanta; 2008 Jul; 76(2):320-6. PubMed ID: 18585284 [TBL] [Abstract][Full Text] [Related]
9. PVC membrane sensor for diclofenac: applications in pharmaceutical analysis and drug binding studies. Maleki R; Matin AA; Hosseinzadeh R; Jouyban A Pharmazie; 2007 Sep; 62(9):672-7. PubMed ID: 17944320 [TBL] [Abstract][Full Text] [Related]
10. Improving the detection limits of antispasmodic drugs electrodes by using modified membrane sensors with inner solid contact. Ibrahim H; Issa YM; Abu-Shawish HM J Pharm Biomed Anal; 2007 May; 44(1):8-15. PubMed ID: 17383844 [TBL] [Abstract][Full Text] [Related]
11. Determination of cobalt ions at nano-level based on newly synthesized pendant armed macrocycle by polymeric membrane and coated graphite electrode. Singh AK; Singh P; Bhattacharjee G Talanta; 2009 Dec; 80(2):685-93. PubMed ID: 19836538 [TBL] [Abstract][Full Text] [Related]
12. Characteristics of new composite- and classical potentiometric sensors for the determination of pioglitazone in some pharmaceutical formulations. Mostafa GA; Al-Majed A J Pharm Biomed Anal; 2008 Sep; 48(1):57-61. PubMed ID: 18555633 [TBL] [Abstract][Full Text] [Related]
13. Flow injection determination of ketotifen fumarate using PVC membrane selective electrodes. Khater MM; Issa YM; Mohammed SH Bioelectrochemistry; 2009 Nov; 77(1):53-9. PubMed ID: 19682958 [TBL] [Abstract][Full Text] [Related]
14. Determination of gadolinium(III) ions in soil and sediment samples by a novel gadolinium membrane sensor based on 6-methyl-4-{[1-(2-thienyl)methylidene]amino}3-thioxo-3,4-dihydro-1,2,4-triazin-5-(2H)-one. Zamani HA; Rajabzadeh G; Ganjali MR; Norouzi P Anal Chim Acta; 2007 Aug; 598(1):51-7. PubMed ID: 17693306 [TBL] [Abstract][Full Text] [Related]
15. A mercury(II) selective sensor based on N,N'-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples. Abu-Shawish HM J Hazard Mater; 2009 Aug; 167(1-3):602-8. PubMed ID: 19195781 [TBL] [Abstract][Full Text] [Related]
16. A selective and sensitive carbon composite coated platinum electrode for aluminium determination in pharmaceutical and mineral water samples. Abbaspour A; Refahi M; Khalafi-nezhad A; Soltani Rad MN; Behrouz S Anal Chim Acta; 2010 Mar; 662(1):76-81. PubMed ID: 20152268 [TBL] [Abstract][Full Text] [Related]
17. Application of 8-amino-N-(2-hydroxybenzylidene)naphthyl amine as a neutral ionophore in the construction of a lanthanum ion-selective sensor. Ganjali MR; Norouzi P; Alizadeh T; Adib M Anal Chim Acta; 2006 Aug; 576(2):275-82. PubMed ID: 17723643 [TBL] [Abstract][Full Text] [Related]
18. Fabrication of a novel iron(III)-PVC membrane sensor based on a new 1,1'-(iminobis(methan-1-yl-1-ylidene))dinaphthalen-2-ol synthetic ionophore for direct and indirect determination of free iron species in some biological and non-biological samples. Babakhanian A; Gholivand MB; Mohammadi M; Khodadadian M; Shockravi A; Abbaszadeh M; Ghanbary A J Hazard Mater; 2010 May; 177(1-3):159-66. PubMed ID: 20056323 [TBL] [Abstract][Full Text] [Related]
19. Septonex-tetraphenylborate screen-printed ion selective electrode for the potentiometric determination of Septonex in pharmaceutical preparations. Mohamed GG; El-Shahat MF; Al-Sabagh AM; Migahed MA; Ali TA Analyst; 2011 Apr; 136(7):1488-95. PubMed ID: 21286616 [TBL] [Abstract][Full Text] [Related]
20. Potentiometric membrane sensor based on 6-(4-nitrophenyl)-2,4-diphenyl-3,5-diaza-bicyclo[3.1.0]hex-2-ene for detection of Sn(II) in real samples. Arvand M; Moghimi AM; Afshari A; Mahmoodi N Anal Chim Acta; 2006 Oct; 579(1):102-8. PubMed ID: 17723734 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]