201 related articles for article (PubMed ID: 18375099)
1. Chronic traumatic pseudoaneurysm of polytetrafluoroethylene axillofemoral bypass graft in a quadriplegic patient.
Grochow RM; Raffetto JD
Ann Vasc Surg; 2008 Sep; 22(5):688-91. PubMed ID: 18375099
[TBL] [Abstract][Full Text] [Related]
2. Nonanastomotic pseudoaneurysm with complete disruption of an expanded polytetrafluoroethylene axillofemoral bypass graft.
Shibutani S; Obara H; Kakefuda T; Kitagawa Y
Ann Vasc Surg; 2012 Apr; 26(3):422.e9-12. PubMed ID: 22285346
[TBL] [Abstract][Full Text] [Related]
3. Chronic anastomotic pseudoaneurysm on a polytetrafluoroethylene axillobifemoral bypass graft.
Jebara V; Aoun T; Dahdah P; Fikani A
J Vasc Surg; 2016 Nov; 64(5):1484. PubMed ID: 27776702
[No Abstract] [Full Text] [Related]
4. Nonanastomotic pseudoaneurysm of expanded polytetrafluoroethylene axillofemoral bypass graft.
Piazza D; Ameli FM; von Schroeder HP; Lossing A
J Vasc Surg; 1993 Apr; 17(4):777-9. PubMed ID: 8464101
[TBL] [Abstract][Full Text] [Related]
5. Traumatic fracture of polytetrafluoroethylene axillofemoral bypass graft.
Kitowski NJ; Gundersen SB
Vasc Endovascular Surg; 2010 Feb; 44(2):131-3. PubMed ID: 20034944
[TBL] [Abstract][Full Text] [Related]
6. Double localization of a non-anastomotic pseudoaneurysm after an axillofemoral bypass: a case report and review of the literature.
Bensaid B; Bakkali T; Tijani Y; Elkhalloufi S; Lekehal B; Sefiani Y; El Mesnaoui A; Bensaid Y
J Med Case Rep; 2017 Jan; 11(1):3. PubMed ID: 28049544
[TBL] [Abstract][Full Text] [Related]
7. Unusual pseudoaneurysm of an axillofemoral bypass caused by seat belt trauma: case report.
Krüger K; Landwehr P; Kristen F; Gossmann A; Lackner K
J Trauma; 1999 Jan; 46(1):189-91. PubMed ID: 9932706
[No Abstract] [Full Text] [Related]
8. Transbrachial endovascular exclusion of an axillary artery pseudoaneurysm with PTFE-covered stents.
Marston WA; Criado E; Mauro MA; Keagy BA
J Endovasc Surg; 1995 May; 2(2):172-6. PubMed ID: 9234131
[TBL] [Abstract][Full Text] [Related]
9. Traumatic nonanastomotic pseudoaneurysm of axillofemoral bypass graft: a case report and review of the literature.
Mousa AY; Nanjundappa A; Abu-Halimah S; Aburahma AF
Vasc Endovascular Surg; 2013 Jan; 47(1):57-60. PubMed ID: 23081890
[TBL] [Abstract][Full Text] [Related]
10. True aneurysm formation in axillofemoral bypass with a reinforced ePTFE graft-a case report.
Oz BS; Yilmaz AT; Gunay C; Bulakbaşi N; Tatar H
Vasc Endovascular Surg; 2002; 36(4):327-9. PubMed ID: 15599486
[TBL] [Abstract][Full Text] [Related]
11. Disruption in "Nonanastomotic Section" of an Axillofemoral Bypass: A Thorough Critical Review of the Literature.
Valverde García S; Peña Cortés R; Torre Eiriz J; García-Cenador MB; Lozano Sánchez FS
Ann Vasc Surg; 2017 Nov; 45():299-304. PubMed ID: 28712961
[TBL] [Abstract][Full Text] [Related]
12. A novel hybrid device for avoiding redo surgery in synchronous iliac and femoral peri-anastomotic pseudo-aneurysms.
Varcoe RL; Jayamanne D; Tiwari A; Swinnen J
Vasc Endovascular Surg; 2008 Dec-2009 Jan; 42(6):579-82. PubMed ID: 18662908
[TBL] [Abstract][Full Text] [Related]
13. Pseudo aneurysm of a 21 year old ePTFE femoro-femoral crossover graft: successful endovascular repair using an ePTFE lined nitinol stent graft.
Subramanian K; Hassouna A; Bahal V; Walter D
Perspect Vasc Surg Endovasc Ther; 2010 Dec; 22(4):250-3. PubMed ID: 21411465
[TBL] [Abstract][Full Text] [Related]
14. Endovascular repair of an axillary artery pseudoaneurysm attributed to hyperextension injury.
Michaluk BT; Deutsch E; Moufid R; Panetta TF
Ann Vasc Surg; 2009; 23(3):412.e5-9. PubMed ID: 18835517
[TBL] [Abstract][Full Text] [Related]
15. Multivariate analysis of long-term results after an axillobifemoral and aortobifemoral bypass in patients with aortoiliac occlusive disease.
Onohara T; Komori K; Kume M; Ishida M; Ohta S; Takeuchi K; Matsumoto T; Sugimachi K
J Cardiovasc Surg (Torino); 2000 Dec; 41(6):905-10. PubMed ID: 11232974
[TBL] [Abstract][Full Text] [Related]
16. Long-term outcome after treatment of aortic graft infection with staged extra-anatomic bypass grafting and aortic graft removal.
Seeger JM; Pretus HA; Welborn MB; Ozaki CK; Flynn TC; Huber TS
J Vasc Surg; 2000 Sep; 32(3):451-9; discussion 460-1. PubMed ID: 10957651
[TBL] [Abstract][Full Text] [Related]
17. Endovascular treatment of a long-term complication of thoraco-bifemoral bypass.
Mascia D; Bertoglio L; Civilini E; Kahlberg A; Tshomba Y; Chiesa R
J Cardiovasc Surg (Torino); 2017 Feb; 58(1):136-138. PubMed ID: 26344379
[No Abstract] [Full Text] [Related]
18. [Use of balloon-expandable stent graft for treatment of a false pseudoaneurysm of the proximal anastomosis of the iliac-femoral bypass graft].
Tsygankov VN; Frantsevich AM; Petrushin KV; Zotikov AE
Angiol Sosud Khir; 2014; 20(1):75-9. PubMed ID: 24722023
[TBL] [Abstract][Full Text] [Related]
19. Endovascular repair of ascending aortic pseudoaneurysm: technical considerations of a common carotid artery approach using the Zenith aortic cuff endograft.
Lin PH; Kougias P; Huynh TT; Huh J; Coselli JS
J Endovasc Ther; 2007 Dec; 14(6):794-8. PubMed ID: 18052591
[TBL] [Abstract][Full Text] [Related]
20. [False anastomotic iliac (prosthesis-prosthesis) aneurysms: treatment with covered endoprostheses].
Lasry JL; Borie H; Coppé G; Hovasse D; Pernès JM
J Mal Vasc; 2003 Apr; 28(2):85-8. PubMed ID: 12750639
[No Abstract] [Full Text] [Related]
[Next] [New Search]