These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

495 related articles for article (PubMed ID: 18376573)

  • 21. Inactivation of Legionella pneumophila by combined systems of copper and silver ions and free chlorine.
    Pianetti A; Sabatini L; Citterio B; Sisti E; Pierfelici L; Bruscolini F
    Ig Sanita Pubbl; 2008 Jan; 64(1):27-40. PubMed ID: 18379604
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species.
    Mouchtouri V; Velonakis E; Hadjichristodoulou C
    Am J Infect Control; 2007 Nov; 35(9):623-7. PubMed ID: 17980243
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Molecular epidemiology of Legionella pneumophila serogroup 1 isolates following long-term chlorine dioxide treatment in a university hospital water system.
    Casini B; Valentini P; Baggiani A; Torracca F; Frateschi S; Nelli LC; Privitera G
    J Hosp Infect; 2008 Jun; 69(2):141-7. PubMed ID: 18439718
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical and environmental distribution of Legionella pneumophila in a university hospital in Italy: efficacy of ultraviolet disinfection.
    Triassi M; Di Popolo A; Ribera D'Alcalà G; Albanese Z; Cuccurullo S; Montegrosso S; Crispino M; Borella P; Zarrilli R
    J Hosp Infect; 2006 Apr; 62(4):494-501. PubMed ID: 16455159
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Use of copper-silver ionization for the control of legionellae in alkaline environments at health care facilities.
    Dziewulski DM; Ingles E; Codru N; Strepelis J; Schoonmaker-Bopp D
    Am J Infect Control; 2015 Sep; 43(9):971-6. PubMed ID: 26149750
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Possible phosphate interference with copper-silver ionization for Legionella control.
    Lin YE; Vidic RD
    J Hosp Infect; 2006 Jan; 62(1):119. PubMed ID: 16214260
    [No Abstract]   [Full Text] [Related]  

  • 27. Silver/copper ionisation treatment of water to reduce the risk of Legionella in NHS healthcare premises. Water Quality Working Group-4.
    Dobson C; Griffiths D; Thomas S; Lee J
    Health Estate J; 1997 May; 51(4):7-8, 10. PubMed ID: 10169415
    [No Abstract]   [Full Text] [Related]  

  • 28. From legionnaire to guerrilla combatant: suppression of Legionella pneumophila in a hospital cold water supply.
    Wagenvoort JH; Sijstermans ML
    J Hosp Infect; 2004 Oct; 58(2):162-3. PubMed ID: 15474192
    [No Abstract]   [Full Text] [Related]  

  • 29. Nosocomial outbreak of Legionella pneumophila serogroup 3 pneumonia in a new bone marrow transplant unit: evaluation, treatment and control.
    Oren I; Zuckerman T; Avivi I; Finkelstein R; Yigla M; Rowe JM
    Bone Marrow Transplant; 2002 Aug; 30(3):175-9. PubMed ID: 12189536
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Controlling Legionella pneumophila in water systems at reduced hot water temperatures with copper and silver ionization.
    Cloutman-Green E; Barbosa VL; Jimenez D; Wong D; Dunn H; Needham B; Ciric L; Hartley JC
    Am J Infect Control; 2019 Jul; 47(7):761-766. PubMed ID: 30661910
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Management of the Legionella-link risk in a multicentre area's hospital: lessons learned of a six-year experience].
    Lecointe D; Fagundez E; Pierron P; Musset JP; Brissé P; Vollereau D; Breton D; Théodora C; Beauvais R; Malbrunot C; Crine L; Fèvre C;
    Pathol Biol (Paris); 2010 Apr; 58(2):131-6. PubMed ID: 19875245
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Chlorine, heat: popular ways to beat Legionella.
    Wireman JW; Schmidt A; Hutchins DT
    Health Facil Manage; 1992 May; 5(5):28, 30, 32-4. PubMed ID: 10118020
    [No Abstract]   [Full Text] [Related]  

  • 33. Safety and efficacy of chlorine dioxide for Legionella control in a hospital water system.
    Zhang Z; McCann C; Stout JE; Piesczynski S; Hawks R; Vidic R; Yu VL
    Infect Control Hosp Epidemiol; 2007 Aug; 28(8):1009-12. PubMed ID: 17620253
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Legionella contamination in the hospital environment: monitoring of the hot water distribution systems of three hospitals in Catania (Italy)].
    Pignato S; Coniglio MA; Faro G; Cantaro P; Carini SA; Mangano G; Cunsolo R; Coco G; Giammanco G
    Ig Sanita Pubbl; 2006; 62(6):635-52. PubMed ID: 17256019
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Cold tap water as a source of fatal nosocomial pneumonia due to Legionella pneumophila in a rehabilitation center].
    Hoebe CJ; Cluitmans JJ; Wagenvoort JH; van Leeuwen WJ; Bilkert-Mooiman MA
    Ned Tijdschr Geneeskd; 1999 May; 143(20):1041-5. PubMed ID: 10368731
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Hospital-wide Eradication of a Nosocomial Legionella pneumophila Serogroup 1 Outbreak.
    Bartley PB; Ben Zakour NL; Stanton-Cook M; Muguli R; Prado L; Garnys V; Taylor K; Barnett TC; Pinna G; Robson J; Paterson DL; Walker MJ; Schembri MA; Beatson SA
    Clin Infect Dis; 2016 Feb; 62(3):273-279. PubMed ID: 26462745
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Special report. Legionnaire's disease: still a problem for hospitals but a costly one to solve.
    Hosp Secur Saf Manage; 1992 Sep; 13(5):5-7. PubMed ID: 10122696
    [No Abstract]   [Full Text] [Related]  

  • 38. Water disinfection with ozone, copper and silver ions, and temperature increase to control Legionella: seven years of experience in a university teaching hospital.
    Blanc DS; Carrara P; Zanetti G; Francioli P
    J Hosp Infect; 2005 May; 60(1):69-72. PubMed ID: 15823660
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Active clinical surveillance for detection of Legionnaires' disease: implications for health care structures].
    Marchesi I; Bargellini A; Cencetti S; Marchegiano P; Cauteruccio L; Casolari C; Borella P
    Ann Ig; 2007; 19(4):295-302. PubMed ID: 17937322
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Practical experience with control of Legionella in cold water circulation systems by water conditioning measures].
    Germann R; Henkels WD; Challinor CJ
    Schriftenr Ver Wasser Boden Lufthyg; 1993; 91():241-8. PubMed ID: 8235480
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 25.