These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 18377021)

  • 1. Capacitive-based dilatometer cell constructed of fused quartz for measuring the thermal expansion of solids.
    Neumeier JJ; Bollinger RK; Timmins GE; Lane CR; Krogstad RD; Macaluso J
    Rev Sci Instrum; 2008 Mar; 79(3):033903. PubMed ID: 18377021
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sapphire dilatometer cell for measuring the thermal expansion of solids.
    Neumeier JJ; Nelson GA
    Rev Sci Instrum; 2022 Jun; 93(6):063903. PubMed ID: 35778030
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Low temperature thermal expansion measurements on optical materials.
    Browder JS; Ballard SS
    Appl Opt; 1969 Apr; 8(4):793-8. PubMed ID: 20072314
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Capacitance determination of the area thermal expansion of dielectric crystals.
    Legge JC; Robinson MC; Shapiro MM
    Rev Sci Instrum; 1979 Jul; 50(7):832-4. PubMed ID: 18699615
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thermal expansion of silver iodide-silver molybdate glasses at low temperatures.
    Mandanici A; Raimondo A; Cutroni M; Ramos MA; Rodrigo JG; Vieira S; Armellini C; Rocca F
    J Chem Phys; 2009 May; 130(20):204508. PubMed ID: 19485458
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A compact and miniaturized high resolution capacitance dilatometer for measuring thermal expansion and magnetostriction.
    Küchler R; Bauer T; Brando M; Steglich F
    Rev Sci Instrum; 2012 Sep; 83(9):095102. PubMed ID: 23020414
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High resolution miniature dilatometer based on an atomic force microscope piezocantilever.
    Park JH; Graf D; Murphy TP; Schmiedeshoff GM; Tozer SW
    Rev Sci Instrum; 2009 Nov; 80(11):116101. PubMed ID: 19947765
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The world's smallest capacitive dilatometer, for high-resolution thermal expansion and magnetostriction in high magnetic fields.
    Küchler R; Wörl A; Gegenwart P; Berben M; Bryant B; Wiedmann S
    Rev Sci Instrum; 2017 Aug; 88(8):083903. PubMed ID: 28863703
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A simple capacitive cell for the measurement of liquids dielectric constant under transient thermal conditions.
    Baudot A; Bret JL
    Cryo Letters; 2003; 24(1):5-16. PubMed ID: 12644848
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diamond thermal expansion measurement using transmitted X-ray back-diffraction.
    Giles C; Adriano C; Lubambo AF; Cusatis C; Mazzaro I; Hönnicke MG
    J Synchrotron Radiat; 2005 May; 12(Pt 3):349-53. PubMed ID: 15840921
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-resolution thermal expansion measurements under helium-gas pressure.
    Manna RS; Wolf B; de Souza M; Lang M
    Rev Sci Instrum; 2012 Aug; 83(8):085111. PubMed ID: 22938336
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A high-precision apparatus for the characterization of thermal interface materials.
    Kempers R; Kolodner P; Lyons A; Robinson AJ
    Rev Sci Instrum; 2009 Sep; 80(9):095111. PubMed ID: 19791968
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A high-stability non-contact dilatometer for low-amplitude temperature-modulated measurements.
    Luckabauer M; Sprengel W; Würschum R
    Rev Sci Instrum; 2016 Jul; 87(7):075116. PubMed ID: 27475604
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Direct continuous measurements of thermal expansion coefficients of liquids and solids using flow microcalorimetry.
    Fortier JL; Simard MA; Picker P; Jolicoeur C
    Rev Sci Instrum; 1979 Nov; 50(11):1474. PubMed ID: 18699414
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Laser interferometric thermometry for substrate temperature measurement.
    Saenger KL; Gupta J
    Appl Opt; 1991 Apr; 30(10):1221-6. PubMed ID: 20582132
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous measurement of magnetization and magnetostriction in 50 T pulsed high magnetic fields.
    Doerr M; Lorenz W; Neupert T; Loewenhaupt M; Kozlova NV; Freudenberger J; Bartkowiak M; Kampert E; Rotter M
    Rev Sci Instrum; 2008 Jun; 79(6):063902. PubMed ID: 18601412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Integrated electronic transport and thermometry at milliKelvin temperatures and in strong magnetic fields.
    Samkharadze N; Kumar A; Manfra MJ; Pfeiffer LN; West KW; Csáthy GA
    Rev Sci Instrum; 2011 May; 82(5):053902. PubMed ID: 21639513
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A temperature insensitive quartz microbalance.
    Pierce DE; Kim Y; Vig JR
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(5):1238-45. PubMed ID: 18244285
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Apparatus for Measuring the Thermal Expansion of Optical Materials from 30 degrees C to 250 degrees C.
    Ebersole JF; Ballard SS; Browder JS
    Appl Opt; 1972 Apr; 11(4):844-8. PubMed ID: 20119055
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A temperature-modulated dilatometer by using a piezobender-based device.
    Gu Y; Liu B; Hong W; Liu Z; Zhang W; Ma X; Li S
    Rev Sci Instrum; 2020 Dec; 91(12):123901. PubMed ID: 33379959
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.