256 related articles for article (PubMed ID: 18379405)
1. Vertebral artery injury during cervical spine surgery: a survey of more than 5600 operations.
Neo M; Fujibayashi S; Miyata M; Takemoto M; Nakamura T
Spine (Phila Pa 1976); 2008 Apr; 33(7):779-85. PubMed ID: 18379405
[TBL] [Abstract][Full Text] [Related]
2. Vertebral artery injuries in cervical spine surgery.
Lunardini DJ; Eskander MS; Even JL; Dunlap JT; Chen AF; Lee JY; Ward TW; Kang JD; Donaldson WF
Spine J; 2014 Aug; 14(8):1520-5. PubMed ID: 24411832
[TBL] [Abstract][Full Text] [Related]
3. Iatrogenic Vertebral Artery Injury During Anterior Cervical Spine Surgery: A Systematic Review.
Guan Q; Chen L; Long Y; Xiang Z
World Neurosurg; 2017 Oct; 106():715-722. PubMed ID: 28712898
[TBL] [Abstract][Full Text] [Related]
4. Endovascular embolization of iatrogenic vertebral artery injury during anterior cervical spine surgery: report of two cases and review of the literature.
Choi JW; Lee JK; Moon KS; Kim YS; Kwak HJ; Joo SP; Kim JH; Kim SH
Spine (Phila Pa 1976); 2006 Nov; 31(23):E891-4. PubMed ID: 17077727
[TBL] [Abstract][Full Text] [Related]
5. Misdiagnosis and management of iatrogenic pseudoaneurysm of vertebral artery after Harms technique of C₁-C₂ fixation.
Min L; Song YM; Xie XD; Wang CH; Liu LM
Chin J Traumatol; 2012; 15(6):355-9. PubMed ID: 23186926
[TBL] [Abstract][Full Text] [Related]
6. Delayed Hemorrhage from an Iatrogenic Vertebral Artery Injury During Anterior Cervical Discectomy and Successful Endovascular Treatment-Report of a Rare Case and Literature Review.
Lo WB; Nagaraja S; Saxena A
World Neurosurg; 2017 Mar; 99():811.e11-811.e18. PubMed ID: 28042015
[TBL] [Abstract][Full Text] [Related]
7. Vertebral artery injury during foraminal decompression in "low-risk" cervical spine surgery: incidence and management.
Obermüller T; Wostrack M; Shiban E; Pape H; Harmening K; Friedrich B; Prothmann S; Meyer B; Ringel F
Acta Neurochir (Wien); 2015 Nov; 157(11):1941-5. PubMed ID: 26416610
[TBL] [Abstract][Full Text] [Related]
8. Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons.
Wright NM; Lauryssen C
J Neurosurg; 1998 Apr; 88(4):634-40. PubMed ID: 9525707
[TBL] [Abstract][Full Text] [Related]
9. Giant delayed pseudo-aneurysm following screw placement in C1 lateral mass.
Guo S; Pan J; Li L; Yang M; Han Y; Wen J; Fan M; Tan J
Orthop Traumatol Surg Res; 2014 Oct; 100(6):691-4. PubMed ID: 25193619
[TBL] [Abstract][Full Text] [Related]
10. Comparison of screw malposition and vertebral artery injury of C2 pedicle and transarticular screws: meta-analysis and review of the literature.
Elliott RE; Tanweer O; Boah A; Morsi A; Ma T; Frempong-Boadu A; Smith ML
J Spinal Disord Tech; 2014 Aug; 27(6):305-15. PubMed ID: 22614268
[TBL] [Abstract][Full Text] [Related]
11. Vertebral artery injury in cervical spine surgery: anatomical considerations, management, and preventive measures.
Peng CW; Chou BT; Bendo JA; Spivak JM
Spine J; 2009; 9(1):70-6. PubMed ID: 18504163
[TBL] [Abstract][Full Text] [Related]
12. Value of intraoperative true lateral radiograph of C2 pedicle for C1-2 transarticular screw insertion.
Liu J; Shafiq Q; Ebraheim NA; Karkare N; Asaad M; Woldenberg L; Yeasting RA
Spine J; 2005; 5(4):434-40. PubMed ID: 15996613
[TBL] [Abstract][Full Text] [Related]
13. Atlantoaxial transarticular screw fixation for a high-riding vertebral artery.
Neo M; Matsushita M; Iwashita Y; Yasuda T; Sakamoto T; Nakamura T
Spine (Phila Pa 1976); 2003 Apr; 28(7):666-70. PubMed ID: 12671353
[TBL] [Abstract][Full Text] [Related]
14. Epidemiology of Iatrogenic Vertebral Artery Injury in Cervical Spine Surgery: 21 Multicenter Studies.
Lee CH; Hong JT; Kang DH; Kim KJ; Kim SW; Kim SW; Kim YJ; Chung CK; Shin JJ; Oh JK; Yi S; Lee JK; Lee JH; Lee HJ; Chun HJ; Cho DC; Jin YJ; Choi KC; Han IH; Hyun SJ; Hur JW; Song GS
World Neurosurg; 2019 Jun; 126():e1050-e1054. PubMed ID: 30878743
[TBL] [Abstract][Full Text] [Related]
15. Vertebral artery injury in cervical spine surgery.
Devin CJ; Kang JD
Instr Course Lect; 2009; 58():717-28. PubMed ID: 19385580
[TBL] [Abstract][Full Text] [Related]
16. Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw.
Yoshida M; Neo M; Fujibayashi S; Nakamura T
Spine (Phila Pa 1976); 2006 Jul; 31(15):E513-7. PubMed ID: 16816753
[TBL] [Abstract][Full Text] [Related]
17. Atlantoaxial transarticular screw fixation with morselized autograft and without additional internal fixation: technical description and report of 57 cases.
Wang C; Yan M; Zhou H; Wang S; Dang G
Spine (Phila Pa 1976); 2007 Mar; 32(6):643-6. PubMed ID: 17413468
[TBL] [Abstract][Full Text] [Related]
18. Vertebral artery pseudoaneurysm complicating posterior C1-2 transarticular screw fixation: case report.
Prabhu VC; France JC; Voelker JL; Zoarski GH
Surg Neurol; 2001 Jan; 55(1):29-33; discussion 33-4. PubMed ID: 11248307
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical analysis comparing three C1-C2 transarticular screw salvaging fixation techniques.
Elgafy H; Potluri T; Goel VK; Foster S; Faizan A; Kulkarni N
Spine (Phila Pa 1976); 2010 Feb; 35(4):378-85. PubMed ID: 20081561
[TBL] [Abstract][Full Text] [Related]
20. Contemporary outcomes of vertebral artery injury.
Alterman DM; Heidel RE; Daley BJ; Grandas OH; Stevens SL; Goldman MH; Freeman MB
J Vasc Surg; 2013 Mar; 57(3):741-6; discussion 746. PubMed ID: 23219513
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]