BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 18381884)

  • 21. Value of the unipolar electrogram in the diagnosis of right ventricular perforation following pacemaker implantation.
    Macdonald J; Kelly D; Waktare J
    Heart; 2005 Feb; 91(2):228. PubMed ID: 15657243
    [No Abstract]   [Full Text] [Related]  

  • 22. Asymptomatic right ventricular perforation by an implantable cardioverter defibrillator lead detected by home monitoring system.
    Migliore F; Leoni L; Torregrossa G; Guglielmi C; Tarantini G; Buja G; Iliceto S; Corrado D
    J Electrocardiol; 2010; 43(6):673-5. PubMed ID: 20888001
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Delayed right-ventricular perforation of a pacemaker lead.
    Hörer J; Will A; Schreiber C
    Pediatr Cardiol; 2011 Jun; 32(5):708-9. PubMed ID: 21472375
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Subepicardial infarction, myocardial impression, and ventricular penetration by sutureless electrode and leads.
    Steinke WE; Thomas FT; ul Hassan Z; Mendoza RA; Gear AS
    Chest; 1976 Jul; 70(1):80-1. PubMed ID: 1277940
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Uncomplicated right ventricular lead perforation diagnosed with computed tomography after permanent pacemaker implantation.
    Kim YS; Oh S; Park KW; Ree Cho K; Choi YS
    Clin Cardiol; 2009 Jul; 32(7):E54. PubMed ID: 17803245
    [No Abstract]   [Full Text] [Related]  

  • 26. Delayed right-ventricular perforation by pacemaker lead; a rare complication in a 12-year-old girl.
    Aykan HH; Akın A; Ertuğrul İ; Karagöz T
    Turk Kardiyol Dern Ars; 2015 Mar; 43(2):185-7. PubMed ID: 25782125
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Delayed perforation of the right ventricle as a complication of permanent cardiac pacing - is following the guidelines always the right choice? Non-standard treatment - a case report and literature review.
    Rydlewska A; Małecka B; Zabek A; Klimeczek P; Lelakowski J; Pasowicz M; Czajkowski M; Kutarski A
    Kardiol Pol; 2010 Mar; 68(3):357-61. PubMed ID: 20411465
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Successful management of a late right ventricular and diaphragmatic perforation by a defibrillator lead.
    Fuenmayor A AJ; Rodríguez S YA
    Europace; 2014 Jun; 16(6):886. PubMed ID: 24008496
    [No Abstract]   [Full Text] [Related]  

  • 29. Hiccup as a result of late lead perforation: report of two cases and review of the literature.
    Celik T; Kose S; Bugan B; Iyisoy A; Akgun V; Cingoz F
    Europace; 2009 Jul; 11(7):963-5. PubMed ID: 19359331
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Subacute presentation of right ventricular perforation after pacemaker implantation.
    Koyama S; Itatani K; Kyo S; Aoyama R; Ishiyama T; Harada K; Ono M
    Ann Thorac Cardiovasc Surg; 2013; 19(1):73-5. PubMed ID: 22673606
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Three-dimensional echocardiographic documentation of pacemaker lead perforation presenting as acute pericarditis.
    Stefanidis AS; Margos PN; Kotsakis AA; Papasteriadis EG
    Hellenic J Cardiol; 2009; 50(4):335-7. PubMed ID: 19622505
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Uncomplicated prior right ventricular perforation due to a pacemaker lead - an incidental finding during coronary artery bypass surgery.
    Yerebakan C; Westphal B; Bayraktar S; Alozie A; Liebold A; Steinhoff G
    Wien Med Wochenschr; 2011 Dec; 161(23-24):578-9. PubMed ID: 22223260
    [TBL] [Abstract][Full Text] [Related]  

  • 33. "The attack of the 52 cm lead": an unusual case of late cardiac perforation by a passive-fixation permanent pacemaker lead.
    Ramirez MF; Ching CK; Ho KL; Teo WS
    Int J Cardiol; 2007 Jan; 115(1):e5-7. PubMed ID: 16901560
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Delayed right ventricular perforation with a pacemaker lead into subcutaneous tissues.
    Amara W; Cymbalista M; Sergent J
    Arch Cardiovasc Dis; 2010 Jan; 103(1):53-4. PubMed ID: 20142121
    [No Abstract]   [Full Text] [Related]  

  • 35. [Ventricle perforation caused by intracardiac pacemaker electrodes].
    Wenzel KP
    Zentralbl Chir; 1971 Jan; 96(5):161-70. PubMed ID: 5553933
    [No Abstract]   [Full Text] [Related]  

  • 36. [Heart wall perforation after implantation of pacemaker - it happens].
    Oreziak A
    Kardiol Pol; 2010 Mar; 68(3):362-3. PubMed ID: 20491183
    [No Abstract]   [Full Text] [Related]  

  • 37. Late perforation of the heart, pericardium, and diaphragm by an active-fixation ventricular lead.
    Akyol A; Aydin A; Erdinler I; Oguz E
    Pacing Clin Electrophysiol; 2005 Apr; 28(4):350-1. PubMed ID: 15826277
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Perforations of right heart chambers associated with electrophysiology catheters and temporary transvenous pacing leads.
    Aliyev F; Celiker C; Türkoğlu C; Karadağ B; Yıldız A
    Turk Kardiyol Dern Ars; 2011 Jan; 39(1):16-22. PubMed ID: 21358226
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Letter: Cardiac perforation by temporary pacing electrodes.
    Htoo MM; Raj MV; Evans DW
    Br Med J; 1975 Feb; 1(5953):331. PubMed ID: 1111800
    [No Abstract]   [Full Text] [Related]  

  • 40. Late right ventricular perforation: a rare complication of a pacemaker implantation.
    Guardado J; Pereira VH; Fernandes M; Sanfins V; Monteiro V; Pinho P; Lourenço A
    Rev Port Cir Cardiotorac Vasc; 2012; 19(1):17-9. PubMed ID: 23641469
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.