These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 18382049)

  • 1. Multichannel surface recordings on the visual cortex: implications for a neuroprosthesis.
    Chelvanayagam DK; Vickery RM; Kirkcaldie MT; Coroneo MT; Morley JW
    J Neural Eng; 2008 Jun; 5(2):125-32. PubMed ID: 18382049
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo electrical stimulation of rabbit retina with a microfabricated array: strategies to maximize responses for prospective assessment of stimulus efficacy and biocompatibility.
    Rizzo JF; Goldbaum S; Shahin M; Denison TJ; Wyatt J
    Restor Neurol Neurosci; 2004; 22(6):429-43. PubMed ID: 15798362
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of extraocular electrodes for a retinal prosthesis using evoked potentials in cat visual cortex.
    Chowdhury V; Morley JW; Coroneo MT
    J Clin Neurosci; 2005 Jun; 12(5):574-9. PubMed ID: 16051097
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of stimulus parameters and electrode geometry for an effective suprachoroidal retinal prosthesis.
    Shivdasani MN; Luu CD; Cicione R; Fallon JB; Allen PJ; Leuenberger J; Suaning GJ; Lovell NH; Shepherd RK; Williams CE
    J Neural Eng; 2010 Jun; 7(3):036008. PubMed ID: 20479521
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of electrically evoked cortical potential thresholds generated with subretinal or suprachoroidal placement of a microelectrode array in the rabbit.
    Yamauchi Y; Franco LM; Jackson DJ; Naber JF; Ziv RO; Rizzo JF; Kaplan HJ; Enzmann V
    J Neural Eng; 2005 Mar; 2(1):S48-56. PubMed ID: 15876654
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Visual cortex responses to single- and simultaneous multiple-electrode stimulation of the retina: implications for retinal prostheses.
    Shivdasani MN; Fallon JB; Luu CD; Cicione R; Allen PJ; Morley JW; Williams CE
    Invest Ophthalmol Vis Sci; 2012 Sep; 53(10):6291-300. PubMed ID: 22899754
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Suprachoroidal electrical stimulation: effects of stimulus pulse parameters on visual cortical responses.
    John SE; Shivdasani MN; Williams CE; Morley JW; Shepherd RK; Rathbone GD; Fallon JB
    J Neural Eng; 2013 Oct; 10(5):056011. PubMed ID: 23928717
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prediction of cortical responses to simultaneous electrical stimulation of the retina.
    Halupka KJ; Shivdasani MN; Cloherty SL; Grayden DB; Wong YT; Burkitt AN; Meffin H
    J Neural Eng; 2017 Feb; 14(1):016006. PubMed ID: 27900949
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Focal activation of the feline retina via a suprachoroidal electrode array.
    Wong YT; Chen SC; Seo JM; Morley JW; Lovell NH; Suaning GJ
    Vision Res; 2009 Mar; 49(8):825-33. PubMed ID: 19272402
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Neural responses in cat visual cortex reflect state changes in correlated activity.
    van der Togt C; Spekreijse H; Supèr H
    Eur J Neurosci; 2005 Jul; 22(2):465-75. PubMed ID: 16045499
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surface stimulation of the brain with a prototype array for a visual cortex prosthesis.
    Chowdhury V; Morley JW; Coroneo MT
    J Clin Neurosci; 2004 Sep; 11(7):750-5. PubMed ID: 15337140
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transscleral implantation and neurophysiological testing of subretinal polyimide film electrodes in the domestic pig in visual prosthesis development.
    Sachs HG; Schanze T; Brunner U; Sailer H; Wiesenack C
    J Neural Eng; 2005 Mar; 2(1):S57-64. PubMed ID: 15876656
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cortical activation following chronic passive implantation of a wide-field suprachoroidal retinal prosthesis.
    Villalobos J; Fallon JB; Nayagam DA; Shivdasani MN; Luu CD; Allen PJ; Shepherd RK; Williams CE
    J Neural Eng; 2014 Aug; 11(4):046017. PubMed ID: 24965866
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An in-vivo paradigm for the evaluation of stimulating electrodes for use with a visual prosthesis.
    Chowdhury V; Morley JW; Coroneo MT
    ANZ J Surg; 2004 May; 74(5):372-8. PubMed ID: 15144260
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrical stimulation with a needle-type electrode inserted into the optic nerve in rabbit eyes.
    Sakaguchi H; Fujikado T; Kanda H; Osanai M; Fang X; Nakauchi K; Ikuno Y; Kamei M; Ohji M; Yagi T; Tano Y
    Jpn J Ophthalmol; 2004; 48(6):552-7. PubMed ID: 15592779
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Synchronization in monkey visual cortex analyzed with an information-theoretic measure.
    Manyakov NV; Van Hulle MM
    Chaos; 2008 Sep; 18(3):037130. PubMed ID: 19045504
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stimulation of the retina with a multielectrode extraocular visual prosthesis.
    Chowdhury V; Morley JW; Coroneo MT
    ANZ J Surg; 2005 Aug; 75(8):697-704. PubMed ID: 16076336
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optical imaging of visual cortical responses evoked by transcorneal electrical stimulation with different parameters.
    Ma Z; Cao P; Sun P; Li L; Lu Y; Yan Y; Chen Y; Chai X
    Invest Ophthalmol Vis Sci; 2014 Jul; 55(8):5320-31. PubMed ID: 25082881
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thresholds for activation of rabbit retinal ganglion cells with a subretinal electrode.
    Jensen RJ; Rizzo JF
    Exp Eye Res; 2006 Aug; 83(2):367-73. PubMed ID: 16616739
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Characteristics of the response of rabbit visual cortex neurons to intracortical electric stimulation].
    Polianskiĭ VB; Latanov AV; Ruderman GL
    Neirofiziologiia; 1983; 15(4):412-9. PubMed ID: 6312340
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.