211 related articles for article (PubMed ID: 18384193)
1. The tripole linear ion trap with highly efficient orthogonal ion ejection designed by computer simulations.
Salazar GA; Masujima T
Rapid Commun Mass Spectrom; 2008 May; 22(9):1351-8. PubMed ID: 18384193
[TBL] [Abstract][Full Text] [Related]
2. Computer simulation of the gap-tripole ion trap with linear injection, 3D ion accumulation, and versatile packet ejection.
Salazar GA; Masujima T
J Am Soc Mass Spectrom; 2008 Sep; 19(9):1367-74. PubMed ID: 18635376
[TBL] [Abstract][Full Text] [Related]
3. Simulation of external ion injection, cooling and extraction processes with SIMION 6.0 for the ion trap/reflectron time-of-flight mass spectrometer.
He L; Lubman DM
Rapid Commun Mass Spectrom; 1997; 11(13):1467-77. PubMed ID: 9299763
[TBL] [Abstract][Full Text] [Related]
4. Computer simulations of a new three rods ion optic (TRIPOLE) with high focusing and mass filtering capabilities.
Salazar GA; Masujima T
J Am Soc Mass Spectrom; 2007 Mar; 18(3):413-21. PubMed ID: 17142055
[TBL] [Abstract][Full Text] [Related]
5. Design of a new multi-turn ion optical system 'IRIS' for a time-of-flight mass spectrometer.
Nishiguchi M; Ueno Y; Toyoda M; Setou M
J Mass Spectrom; 2009 May; 44(5):594-604. PubMed ID: 19034931
[TBL] [Abstract][Full Text] [Related]
6. Mass-selective axial ejection from a linear ion trap with a direct current extraction field.
Sugiyama M; Hasegawa H; Hashimoto Y
Rapid Commun Mass Spectrom; 2009 Sep; 23(18):2917-22. PubMed ID: 19670365
[TBL] [Abstract][Full Text] [Related]
7. Ion trap array mass analyzer: structure and performance.
Li X; Jiang G; Luo C; Xu F; Wang Y; Ding L; Ding CF
Anal Chem; 2009 Jun; 81(12):4840-6. PubMed ID: 19441854
[TBL] [Abstract][Full Text] [Related]
8. Radial stratification of ions as a function of mass to charge ratio in collisional cooling radio frequency multipoles used as ion guides or ion traps.
Tolmachev AV; Udseth HR; Smith RD
Rapid Commun Mass Spectrom; 2000; 14(20):1907-13. PubMed ID: 11013419
[TBL] [Abstract][Full Text] [Related]
9. A combined linear ion trap time-of-flight system with improved performance and MS(n) capabilities.
Collings BA; Campbell JM; Mao D; Douglas DJ
Rapid Commun Mass Spectrom; 2001; 15(19):1777-95. PubMed ID: 11565095
[TBL] [Abstract][Full Text] [Related]
10. Linear ion trap with added octopole field component: the property and method.
Dang Q; Xu F; Huang X; Fang X; Wang R; Ding CF
J Mass Spectrom; 2015 Dec; 50(12):1400-8. PubMed ID: 26634975
[TBL] [Abstract][Full Text] [Related]
11. Axial focusing following low kinetic energy pulsed extraction from a miniature linear ion trap.
Dobson GS; Enke CG
Rapid Commun Mass Spectrom; 2007; 21(17):2905-12. PubMed ID: 17663499
[TBL] [Abstract][Full Text] [Related]
12. Paul trap mass analyzer consisting of opposing microfabricated electrode plates.
Zhang Z; Peng Y; Hansen BJ; Miller IW; Wang M; Lee ML; Hawkins AR; Austin DE
Anal Chem; 2009 Jul; 81(13):5241-8. PubMed ID: 19522534
[TBL] [Abstract][Full Text] [Related]
13. Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer.
Ouyang Z; Wu G; Song Y; Li H; Plass WR; Cooks RG
Anal Chem; 2004 Aug; 76(16):4595-605. PubMed ID: 15307768
[TBL] [Abstract][Full Text] [Related]
14. Characterization of electrode surface roughness and its impact on ion trap mass analysis.
Xu W; Chappell WJ; Cooks RG; Ouyang Z
J Mass Spectrom; 2009 Mar; 44(3):353-60. PubMed ID: 19021150
[TBL] [Abstract][Full Text] [Related]
15. Space-charge effects with mass-selective axial ejection from a linear quadrupole ion trap.
Qiao H; Gao C; Mao D; Konenkov N; Douglas DJ
Rapid Commun Mass Spectrom; 2011 Dec; 25(23):3509-20. PubMed ID: 22095499
[TBL] [Abstract][Full Text] [Related]
16. An electrostatic autoresonant ion trap mass spectrometer.
Ermakov AV; Hinch BJ
Rev Sci Instrum; 2010 Jan; 81(1):013107. PubMed ID: 20113081
[TBL] [Abstract][Full Text] [Related]
17. Characteristics of electrical field and ion motion in surface-electrode ion traps.
Zhou X; Xu G; Xiong C; Chen R; Qiao H; Nie Z
J Mass Spectrom; 2012 Mar; 47(3):286-93. PubMed ID: 22431454
[TBL] [Abstract][Full Text] [Related]
18. Theoretical calculations for mass resolution of a quadrupole ion trap reflectron time-of-flight mass spectrometer.
Choi CM; Heo J; Park CJ; Kim NJ
Rapid Commun Mass Spectrom; 2010 Feb; 24(4):422-8. PubMed ID: 20069692
[TBL] [Abstract][Full Text] [Related]
19. Superimposition of a magnetic field around an ion guide for electron ionization time-of-flight mass spectrometry.
Yue B; Lee ED; Rockwood AL; Lee ML
Anal Chem; 2005 Jul; 77(13):4167-75. PubMed ID: 15987123
[TBL] [Abstract][Full Text] [Related]
20. Model simulations of continuous ion injection into electron-beam ion source trap with slanted electrostatic mirror.
Pikin A; Kponou A; Alessi JG; Beebe EN; Prelec K; Raparia D
Rev Sci Instrum; 2008 Feb; 79(2 Pt 2):02B908. PubMed ID: 18315223
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]