530 related articles for article (PubMed ID: 18401069)
1. Reproducibility of infrared thermography measurements in healthy individuals.
Zaproudina N; Varmavuo V; Airaksinen O; Närhi M
Physiol Meas; 2008 Apr; 29(4):515-24. PubMed ID: 18401069
[TBL] [Abstract][Full Text] [Related]
2. Comparison of infrared thermography and laser speckle contrast imaging for the dynamic assessment of digital microvascular function.
Pauling JD; Shipley JA; Raper S; Watson ML; Ward SG; Harris ND; McHugh NJ
Microvasc Res; 2012 Mar; 83(2):162-7. PubMed ID: 21763703
[TBL] [Abstract][Full Text] [Related]
3. Are the infrared thermography findings skin temperature-dependent? a study on neck pain patients.
Zaproudina N; Airaksinen O; Närhi M
Skin Res Technol; 2013 Feb; 19(1):e537-44. PubMed ID: 23020845
[TBL] [Abstract][Full Text] [Related]
4. Validation of a protocol for the assessment of skin temperature and blood flow in childhood localised scleroderma.
Howell KJ; Lavorato A; Visentin MT; Smith RE; Schaefer G; Jones CD; Weibel L; Denton CP; Harper JI; Woo P
Skin Res Technol; 2009 Aug; 15(3):346-56. PubMed ID: 19624432
[TBL] [Abstract][Full Text] [Related]
5. Paraspinal skin temperature patterns: an interexaminer and intraexaminer reliability study.
Owens EF; Hart JF; Donofrio JJ; Haralambous J; Mierzejewski E
J Manipulative Physiol Ther; 2004; 27(3):155-9. PubMed ID: 15129197
[TBL] [Abstract][Full Text] [Related]
6. Reliability of an infrared forehead skin thermometer for core temperature measurements.
Kistemaker JA; Den Hartog EA; Daanen HA
J Med Eng Technol; 2006; 30(4):252-61. PubMed ID: 16864237
[TBL] [Abstract][Full Text] [Related]
7. Measuring skin temperature before, during and after exercise: a comparison of thermocouples and infrared thermography.
Fernandes Ade A; Amorim PR; Brito CJ; de Moura AG; Moreira DG; Costa CM; Sillero-Quintana M; Marins JC
Physiol Meas; 2014 Feb; 35(2):189-203. PubMed ID: 24398429
[TBL] [Abstract][Full Text] [Related]
8. [Contemporary applications of infrared imaging in medical diagnostics].
Mikulska D
Ann Acad Med Stetin; 2006; 52(1):35-9; discussion 39-40. PubMed ID: 17131845
[TBL] [Abstract][Full Text] [Related]
9. Comparison of temporal artery, mid-forehead skin and axillary temperature recordings in preterm infants <1500 g of birthweight.
Duran R; Vatansever U; Acunaş B; Süt N
J Paediatr Child Health; 2009; 45(7-8):444-7. PubMed ID: 19712180
[TBL] [Abstract][Full Text] [Related]
10. Infrared tympanic temperature and ear canal morphology.
Daanen HA
J Med Eng Technol; 2006; 30(4):224-34. PubMed ID: 16864234
[TBL] [Abstract][Full Text] [Related]
11. Comparative effectiveness of videothermography, contact thermography, and infrared beam thermography for scanning relative skin temperature.
Sherman RA; Woerman AL; Karstetter KW
J Rehabil Res Dev; 1996 Oct; 33(4):377-86. PubMed ID: 8895132
[TBL] [Abstract][Full Text] [Related]
12. Examination of the vascular system of lower extremities with infrared thermography--healthy subjects.
Poláchová I; Smolan S
Acta Univ Palacki Olomuc Fac Med; 1991; 129():139-49. PubMed ID: 1837656
[TBL] [Abstract][Full Text] [Related]
13. Infrared thermography in children: a reliable tool for differential diagnosis of peripheral microvascular dysfunction and Raynaud's phenomenon?
Martini G; Cappella M; Culpo R; Vittadello F; Sprocati M; Zulian F
Pediatr Rheumatol Online J; 2019 Oct; 17(1):68. PubMed ID: 31619252
[TBL] [Abstract][Full Text] [Related]
14. Distribution of skin temperature in Mexican children.
Kolosovas-Machuca ES; González FJ
Skin Res Technol; 2011 Aug; 17(3):326-31. PubMed ID: 21338404
[TBL] [Abstract][Full Text] [Related]
15. Accuracy and reliability of infrared thermography in the diagnosis of arthralgia in women with temporomandibular disorder.
Rodrigues-Bigaton D; Dibai Filho AV; Costa AC; Packer AC; de Castro EM
J Manipulative Physiol Ther; 2013 May; 36(4):253-8. PubMed ID: 23719519
[TBL] [Abstract][Full Text] [Related]
16. [An attempt to determine the variability of thermal phenotypes in monozygotic twins].
Kempińska A
Ann Acad Med Stetin; 2006; 52(3):29-34; discussion 34-5. PubMed ID: 17385346
[TBL] [Abstract][Full Text] [Related]
17. Interexaminer reliability of infrared thermography for the diagnosis of complex regional pain syndrome.
Choi E; Lee PB; Nahm FS
Skin Res Technol; 2013 May; 19(2):189-93. PubMed ID: 23331254
[TBL] [Abstract][Full Text] [Related]
18. Measurements of skin temperature responses to cold exposure of foot and face in healthy individuals: variability and influencing factors.
Zaproudina N; Lipponen JA; Eskelinen P; Tarvainen MP; Karjalainen PA; Närhi M
Clin Physiol Funct Imaging; 2011 Jul; 31(4):307-14. PubMed ID: 21672139
[TBL] [Abstract][Full Text] [Related]
19. Body temperature of healthy men evaluated by thermography: A study of reproducibility.
Alfieri FM; Battistella LR
Technol Health Care; 2018; 26(3):559-564. PubMed ID: 29578493
[TBL] [Abstract][Full Text] [Related]
20. Infrared Skin Thermometry: Validating and Comparing Techniques to Detect Periwound Skin Infection.
Mufti A; Somayaji R; Coutts P; Sibbald RG
Adv Skin Wound Care; 2018 Jan; 31(1):607-611. PubMed ID: 29240589
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]