222 related articles for article (PubMed ID: 18402652)
1. Influence of airway management strategy on "no-flow-time" during an "advanced life support course" for intensive care nurses - a single rescuer resuscitation manikin study.
Wiese CH; Bartels U; Schultens A; Steffen T; Torney A; Bahr J; Graf BM
BMC Emerg Med; 2008 Apr; 8():4. PubMed ID: 18402652
[TBL] [Abstract][Full Text] [Related]
2. Using a laryngeal tube suction-device (LTS-D) reduces the "no flow time" in a single rescuer manikin study.
Wiese CH; Bartels U; Schultens A; Steffen T; Torney A; Bahr J; Graf BM
J Emerg Med; 2011 Aug; 41(2):128-34. PubMed ID: 19217236
[TBL] [Abstract][Full Text] [Related]
3. [Reduction in no flow time using a laryngeal tube: comparison to bag-mask ventilation].
Wiese CH; Bahr J; Bergmann A; Bergmann I; Bartels U; Graf BM
Anaesthesist; 2008 Jun; 57(6):589-96. PubMed ID: 18338138
[TBL] [Abstract][Full Text] [Related]
4. Influence of airway management strategy on "no-flow-time" in a standardized single rescuer manikin scenario (a comparison between LTS-D and I-gel).
Wiese CH; Bahr J; Popov AF; Hinz JM; Graf BM
Resuscitation; 2009 Jan; 80(1):100-3. PubMed ID: 18952347
[TBL] [Abstract][Full Text] [Related]
5. ["Laryngeal Tube-D" (LT-D) and "Laryngeal Mask" (LMA)].
Wiese CH; Bahr J; Graf BM
Dtsch Med Wochenschr; 2009 Jan; 134(3):69-74. PubMed ID: 19085741
[TBL] [Abstract][Full Text] [Related]
6. Effect of using a laryngeal tube on the no-flow time in a simulated, single-rescuer, basic life support setting with inexperienced users.
Meyer O; Bucher M; Schröder J
Anaesthesist; 2016 Mar; 65(3):183-9. PubMed ID: 26886383
[TBL] [Abstract][Full Text] [Related]
7. Basic life support trained nurses ventilate more efficiently with laryngeal mask supreme than with facemask or laryngeal tube suction-disposable--a prospective, randomized clinical trial.
Gruber E; Oberhammer R; Balkenhol K; Strapazzon G; Procter E; Brugger H; Falk M; Paal P
Resuscitation; 2014 Apr; 85(4):499-502. PubMed ID: 24440666
[TBL] [Abstract][Full Text] [Related]
8. Effect of the laryngeal tube on the no-flow-time in a simulated two rescuer basic life support setting with inexperienced users.
Schröder J; Bucher M; Meyer O
Med Klin Intensivmed Notfmed; 2016 Sep; 111(6):493-500. PubMed ID: 26374339
[TBL] [Abstract][Full Text] [Related]
9. Using a laryngeal tube during cardiac arrest reduces "no flow time" in a manikin study: a comparison between laryngeal tube and endotracheal tube.
Wiese CH; Bartels U; Bergmann A; Bergmann I; Bahr J; Graf BM
Wien Klin Wochenschr; 2008; 120(7-8):217-23. PubMed ID: 18500596
[TBL] [Abstract][Full Text] [Related]
10. Does endotracheal intubation increases chest compression fraction in out of hospital cardiac arrest: A substudy of the CAAM trial.
Malinverni S; Bartiaux M; Cavallotto F; De Longueville D; Mols P; Gorlicki J; Adnet F
Resuscitation; 2019 Apr; 137():35-40. PubMed ID: 30753851
[TBL] [Abstract][Full Text] [Related]
11. Comparing no-flow time during endotracheal intubation versus placement of a laryngeal mask airway during a simulated cardiac arrest scenario.
Miller VJ; Flaherty EE
Simul Healthc; 2014 Jun; 9(3):156-60. PubMed ID: 24310162
[TBL] [Abstract][Full Text] [Related]
12. Chest compression fraction in simulated cardiac arrest management by primary care paramedics: King laryngeal tube airway versus basic airway management.
Jensen JL; Walker M; LeRoux Y; Carter A
Prehosp Emerg Care; 2013; 17(2):285-90. PubMed ID: 23305613
[TBL] [Abstract][Full Text] [Related]
13. A randomized controlled trial comparing the ProSeal Laryngeal Mask Airway with the Laryngeal Tube Suction in mechanically ventilated patients.
Gaitini LA; Vaida SJ; Somri M; Yanovski B; Ben-David B; Hagberg CA
Anesthesiology; 2004 Aug; 101(2):316-20. PubMed ID: 15277913
[TBL] [Abstract][Full Text] [Related]
14. Laryngeal mask airway versus bag-mask ventilation or endotracheal intubation for neonatal resuscitation.
Grein AJ; Weiner GM
Cochrane Database Syst Rev; 2005 Apr; (2):CD003314. PubMed ID: 15846656
[TBL] [Abstract][Full Text] [Related]
15. Influence of an impedance threshold valve on ventilation with supraglottic airway devices during cardiopulmonary resuscitation in a manikin.
Genzwuerker HV; Gernoth C; Hinkelbein J; Schmidbauer W; Kerner T
Resuscitation; 2010 Aug; 81(8):1010-3. PubMed ID: 20471153
[TBL] [Abstract][Full Text] [Related]
16. A randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure.
Somri M; Vaida S; Garcia Fornari G; Mendoza GR; Charco-Mora P; Hawash N; Matter I; Swaid F; Gaitini L
BMC Anesthesiol; 2016 Oct; 16(1):87. PubMed ID: 27716165
[TBL] [Abstract][Full Text] [Related]
17. Impact of COVID-19-adapted guidelines using different airway management strategies on resuscitation quality in out-of-hospital-cardiac-arrest - a randomised manikin study.
Scholz SS; Linder S; Latka E; Bartnick T; Karla D; Thaemel D; Wolff M; Sauzet O; Rehberg SW; Thies KC; Jansen G
BMC Emerg Med; 2023 May; 23(1):48. PubMed ID: 37189061
[TBL] [Abstract][Full Text] [Related]
18. [Laryngeal tube II : alternative airway for children?].
Schalk R; Scheller B; Peter N; Rosskopf W; Byhahn C; Zacharowski K; Meininger D
Anaesthesist; 2011 Jun; 60(6):525-33. PubMed ID: 21246182
[TBL] [Abstract][Full Text] [Related]
19. Bag-mask ventilation and direct laryngoscopy versus intubating laryngeal mask airway: a manikin study of hands-on times during cardiopulmonary resuscitation.
Russo SG; Stradtmann C; Crozier TA; Ringer C; Helms HJ; Quintel M; Wiese CH
Eur J Emerg Med; 2014 Jun; 21(3):189-94. PubMed ID: 23502213
[TBL] [Abstract][Full Text] [Related]
20. Mouth-to-mouth ventilation is superior to mouth-to-pocket mask and bag-valve-mask ventilation during lifeguard CPR: a randomized study.
Adelborg K; Dalgas C; Grove EL; Jørgensen C; Al-Mashhadi RH; Løfgren B
Resuscitation; 2011 May; 82(5):618-22. PubMed ID: 21330044
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]