These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
213 related articles for article (PubMed ID: 18406946)
1. Multileaf collimator characteristics and reliability requirements for IMRT Elekta system. Liu C; Simon TA; Fox C; Li J; Palta JR Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S89-92. PubMed ID: 18406946 [TBL] [Abstract][Full Text] [Related]
2. Siemens multileaf collimator characterization and quality assurance approaches for intensity-modulated radiotherapy. Bayouth JE Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S93-7. PubMed ID: 18406947 [TBL] [Abstract][Full Text] [Related]
3. IMRT delivery performance with a varian multileaf collimator. Losasso T Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S85-8. PubMed ID: 18406945 [TBL] [Abstract][Full Text] [Related]
4. An experimental investigation into the radiation field offset of a dynamic multileaf collimator. Vial P; Oliver L; Greer PB; Baldock C Phys Med Biol; 2006 Nov; 51(21):5517-38. PubMed ID: 17047267 [TBL] [Abstract][Full Text] [Related]
5. [Physical-dosimetric characterization of a multi-leaf collimator system for clinical implementation in conformational radiotherapy]. Pasquino M; Casanova Borca V; Tofani S Radiol Med; 2001 Mar; 101(3):187-92. PubMed ID: 11402959 [TBL] [Abstract][Full Text] [Related]
6. Multileaf collimator end leaf leakage: implications for wide-field IMRT. Hardcastle N; Metcalfe P; Ceylan A; Williams MJ Phys Med Biol; 2007 Nov; 52(21):N493-504. PubMed ID: 17951847 [TBL] [Abstract][Full Text] [Related]
7. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration. Baker SJ; Budgell GJ; MacKay RI Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330 [TBL] [Abstract][Full Text] [Related]
8. Integration of real-time internal electromagnetic position monitoring coupled with dynamic multileaf collimator tracking: an intensity-modulated radiation therapy feasibility study. Smith RL; Sawant A; Santanam L; Venkat RB; Newell LJ; Cho BC; Poulsen P; Catell H; Keall PJ; Parikh PJ Int J Radiat Oncol Biol Phys; 2009 Jul; 74(3):868-75. PubMed ID: 19394159 [TBL] [Abstract][Full Text] [Related]
9. Commissioning of volumetric modulated arc therapy (VMAT). Bedford JL; Warrington AP Int J Radiat Oncol Biol Phys; 2009 Feb; 73(2):537-45. PubMed ID: 19147018 [TBL] [Abstract][Full Text] [Related]
10. Toward submillimeter accuracy in the management of intrafraction motion: the integration of real-time internal position monitoring and multileaf collimator target tracking. Sawant A; Smith RL; Venkat RB; Santanam L; Cho B; Poulsen P; Cattell H; Newell LJ; Parikh P; Keall PJ Int J Radiat Oncol Biol Phys; 2009 Jun; 74(2):575-82. PubMed ID: 19327907 [TBL] [Abstract][Full Text] [Related]
11. [Quality control for multileaf collimator leaf position accuracy using amorphous silicon electronic portal imaging devices]. Kang DH; Deng XW; Huang SM Ai Zheng; 2009 Jul; 28(7):771-4. PubMed ID: 19624908 [TBL] [Abstract][Full Text] [Related]
13. Commissioning and quality assurance of RapidArc radiotherapy delivery system. Ling CC; Zhang P; Archambault Y; Bocanek J; Tang G; Losasso T Int J Radiat Oncol Biol Phys; 2008 Oct; 72(2):575-81. PubMed ID: 18793960 [TBL] [Abstract][Full Text] [Related]
14. [The application of the multileaf collimator in radiotherapy: the dosimetric problems and the technical implications for its clinical use]. Corvò R; Foppiano F; Orsatti M; Bisi F; Ghiso G; Martinelli R; Valanzola L; Vitale V Radiol Med; 1997 Nov; 94(5):512-9. PubMed ID: 9465218 [TBL] [Abstract][Full Text] [Related]
15. Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator. Klüter S; Sroka-Perez G; Schubert K; Debus J Phys Med Biol; 2011 Jan; 56(2):N29-37. PubMed ID: 21178240 [TBL] [Abstract][Full Text] [Related]
16. Electromagnetic real-time tumor position monitoring and dynamic multileaf collimator tracking using a Siemens 160 MLC: geometric and dosimetric accuracy of an integrated system. Krauss A; Nill S; Tacke M; Oelfke U Int J Radiat Oncol Biol Phys; 2011 Feb; 79(2):579-87. PubMed ID: 20656420 [TBL] [Abstract][Full Text] [Related]
18. The effect of gantry and collimator angles on leaf limited velocity and position in dynamic multileaf collimator intensity-modulated radiation therapy. Okumura M; Obata Y; Shimomura K; Tamura M; Nishimura Y Phys Med Biol; 2010 Jun; 55(11):3101-13. PubMed ID: 20463373 [TBL] [Abstract][Full Text] [Related]
19. A multileaf collimator phantom for the quality assurance of radiation therapy planning systems and CT simulators. McNiven A; Kron T; Van Dyk J Int J Radiat Oncol Biol Phys; 2004 Nov; 60(3):994-1001. PubMed ID: 15465218 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID. Mohammadi M; Bezak E Phys Med Biol; 2007 Jan; 52(1):N21-33. PubMed ID: 17183123 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]