These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
213 related articles for article (PubMed ID: 18406946)
21. Reducing the number of segments in unidirectional MLC segmentations. Mellado X; Cruz S; Artacho JM; Canellas M Phys Med Biol; 2010 Feb; 55(3):N75-85. PubMed ID: 20057009 [TBL] [Abstract][Full Text] [Related]
22. Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning. Yang Y; Xing L Med Phys; 2003 Mar; 30(3):433-41. PubMed ID: 12674244 [TBL] [Abstract][Full Text] [Related]
23. An EPID-based system for gantry-resolved MLC quality assurance for VMAT. Zwan BJ; Barnes MP; Fuangord T; Stanton CJ; O'Connor DJ; Keall PJ; Greer PB J Appl Clin Med Phys; 2016 Sep; 17(5):348-365. PubMed ID: 27685132 [TBL] [Abstract][Full Text] [Related]
24. Clinical implementation of a commercial multileaf collimator: dosimetry, networking, simulation, and quality assurance. Klein EE; Harms WB; Low DA; Willcut V; Purdy JA Int J Radiat Oncol Biol Phys; 1995 Dec; 33(5):1195-208. PubMed ID: 7493844 [TBL] [Abstract][Full Text] [Related]
25. A novel method for routine quality assurance of volumetric-modulated arc therapy. Wang Q; Dai J; Zhang K Med Phys; 2013 Oct; 40(10):101712. PubMed ID: 24089902 [TBL] [Abstract][Full Text] [Related]
26. Monte Carlo simulation of helical tomotherapy with PENELOPE. Sterpin E; Salvat F; Cravens R; Ruchala K; Olivera GH; Vynckier S Phys Med Biol; 2008 Apr; 53(8):2161-80. PubMed ID: 18385525 [TBL] [Abstract][Full Text] [Related]
27. Evaluation of the Elekta Agility MLC performance using high-resolution log files. Kabat CN; Defoor DL; Myers P; Kirby N; Rasmussen K; Saenz DL; Mavroidis P; Papanikolaou N; Stathakis S Med Phys; 2019 Mar; 46(3):1397-1407. PubMed ID: 30702748 [TBL] [Abstract][Full Text] [Related]
28. Characterization of the Halcyon Lim TY; Dragojević I; Hoffman D; Flores-Martinez E; Kim GY J Appl Clin Med Phys; 2019 Apr; 20(4):106-114. PubMed ID: 30889312 [TBL] [Abstract][Full Text] [Related]
29. Quality assurance of intensity-modulated radiation therapy. Palta JR; Liu C; Li JG Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S108-12. PubMed ID: 18406906 [TBL] [Abstract][Full Text] [Related]
30. Commissioning and quality assurance of RapidArc radiotherapy delivery system: in regard to Ling et al. (Int J Radiat Oncol Biol Phys 2008;72;575-581): Absence of data does not constitute proof; the proof is in tasting the pudding. Mehta M; Hoban P; Mackie TR Int J Radiat Oncol Biol Phys; 2009 Sep; 75(1):4-6; discussion 8-9. PubMed ID: 19695432 [No Abstract] [Full Text] [Related]
31. Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs: issues and how to detect them. Dobler B; Lorenz F; Wertz H; Polednik M; Wolff D; Steil V; Lohr F; Wenz F Strahlenther Onkol; 2006 Aug; 182(8):481-8. PubMed ID: 16896595 [TBL] [Abstract][Full Text] [Related]
32. Technical and dosimetric considerations in multi-isocenter intensity modulated radiotherapy for nasopharyngeal carcinoma with small multileaf collimator. Xiance J; Shixiu W; Jianyi Y; Jinling Y Med Dosim; 2009; 34(1):9-15. PubMed ID: 19181249 [TBL] [Abstract][Full Text] [Related]
33. The performance of multileaf collimators evaluated by the stripe test. Sastre-Padro M; Lervåg C; Eilertsen K; Malinen E Med Dosim; 2009; 34(3):202-6. PubMed ID: 19647629 [TBL] [Abstract][Full Text] [Related]
35. Linearity of the dose monitor system at low monitor units. Mohr P; Brieger S; Stahl J; Witucki G Strahlenther Onkol; 2007 Jun; 183(6):327-31. PubMed ID: 17520187 [TBL] [Abstract][Full Text] [Related]
36. Reconstruction of high resolution MLC leaf positions using a low resolution detector for accurate 3D dose reconstruction in IMRT. Visser R; Godart J; Wauben DJ; Langendijk JA; Van't Veld AA; Korevaar EW Phys Med Biol; 2016 Dec; 61(23):N642-N649. PubMed ID: 27819251 [TBL] [Abstract][Full Text] [Related]
37. An MLC calibration method using a detector array. Simon TA; Kahler D; Simon WE; Fox C; Li J; Palta J; Liu C Med Phys; 2009 Oct; 36(10):4495-503. PubMed ID: 19928080 [TBL] [Abstract][Full Text] [Related]
38. Characterization of positional accuracy of a double-focused and double-stack multileaf collimator on an MR-guided radiotherapy (MRgRT) Linac using an IC-profiler array. Mittauer KE; Yadav P; Paliwal B; Bayouth JE Med Phys; 2020 Feb; 47(2):317-330. PubMed ID: 31682018 [TBL] [Abstract][Full Text] [Related]
39. Analysis of the measurement precision of an amorphous silicon EPID used for MLC leaf position quality control and the long-term calibration stability of an optically controlled MLC. Budgell GJ; Clarke MF Phys Med Biol; 2008 Aug; 53(15):N297-306. PubMed ID: 18635894 [TBL] [Abstract][Full Text] [Related]
40. VMAT testing for an Elekta accelerator. Kaurin DG; Sweeney LE; Marshall EI; Mahendra S J Appl Clin Med Phys; 2012 Mar; 13(2):3725. PubMed ID: 22402389 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]