These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 1840723)

  • 1. Tribology of total artificial joints.
    Fisher J; Dowson D
    Proc Inst Mech Eng H; 1991; 205(2):73-9. PubMed ID: 1840723
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.
    Davidson JA; Poggie RA; Mishra AK
    Biomed Mater Eng; 1994; 4(3):213-29. PubMed ID: 7950870
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of contact area in 'cushion form' bearings for artificial hip joints.
    O'Carroll S; Jin ZM; Dowson D; Fisher J; Jobbins B
    Proc Inst Mech Eng H; 1990; 204(4):217-23. PubMed ID: 2090124
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus.
    Jin ZM; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1997; 211(3):247-56. PubMed ID: 9256001
    [TBL] [Abstract][Full Text] [Related]  

  • 5. How has the introduction of new bearing surfaces altered the biological reactions to byproducts of wear and modularity?
    Wooley PH
    Clin Orthop Relat Res; 2014 Dec; 472(12):3699-708. PubMed ID: 24942963
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles.
    Mirghany M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):41-50. PubMed ID: 14982345
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The lexicon of polyethylene wear in artificial joints.
    McKellop HA
    Biomaterials; 2007 Dec; 28(34):5049-57. PubMed ID: 17706766
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hard bearing surfaces in total hip arthroplasty.
    Jazrawi LM; Kummer FJ; Di Cesare PE
    Am J Orthop (Belle Mead NJ); 1998 Apr; 27(4):283-92. PubMed ID: 9586727
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biological reactions to wear debris in total joint replacement.
    Ingham E; Fisher J
    Proc Inst Mech Eng H; 2000; 214(1):21-37. PubMed ID: 10718048
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of friction and lubrication of different hip prostheses.
    Scholes SC; Unsworth A
    Proc Inst Mech Eng H; 2000; 214(1):49-57. PubMed ID: 10718050
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Friction of composite cushion bearings for total knee joint replacements under adverse lubrication conditions.
    Stewart T; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 1997; 211(6):451-65. PubMed ID: 9509883
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
    Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
    Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tribology of human and artificial joints.
    Unsworth A
    Proc Inst Mech Eng H; 1991; 205(3):163-72. PubMed ID: 1823790
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear.
    Davidson JA
    Clin Orthop Relat Res; 1993 Sep; (294):361-78. PubMed ID: 8358943
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Polyethylene wear and late loosening of a total prosthesis of the hip joint. New perspectives for metal/metal pairing of the capsule and head].
    Weber BG; Fiechter T
    Orthopade; 1989 Sep; 18(5):370-6. PubMed ID: 2812770
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cushion form bearings for total knee joint replacement. Part 2: Wear and durability.
    Auger DD; Dowson D; Fisher J
    Proc Inst Mech Eng H; 1995; 209(2):83-91. PubMed ID: 7495430
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement.
    Lancaster JG; Dowson D; Isaac GH; Fisher J
    Proc Inst Mech Eng H; 1997; 211(1):17-24. PubMed ID: 9141887
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wear mechanisms in ceramic hip implants.
    Slonaker M; Goswami T
    J Surg Orthop Adv; 2004; 13(2):94-105. PubMed ID: 15281406
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The biology of alternative bearing surfaces in total joint arthroplasty.
    Meneghini RM; Hallab NJ; Jacobs JJ
    Instr Course Lect; 2005; 54():481-93. PubMed ID: 15948473
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.