These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 18411600)

  • 1. The percutaneous compression plate versus the dynamic hip screw: a meta-analysis.
    Panesar SS; Mirza S; Bharadwaj G; Woolf V; Ravikumar R; Athanasiou T
    Acta Orthop Belg; 2008 Feb; 74(1):38-48. PubMed ID: 18411600
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Percutaneous compression plating versus compression hip screw fixation for the treatment of intertrochanteric hip fractures.
    Peyser A; Weil Y; Brocke L; Manor O; Mosheiff R; Liebergall M
    Injury; 2005 Nov; 36(11):1343-9. PubMed ID: 16214477
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Perioperative lateral trochanteric wall fractures: sliding hip screw versus percutaneous compression plate for intertrochanteric hip fractures.
    Langford J; Pillai G; Ugliailoro AD; Yang E
    J Orthop Trauma; 2011 Apr; 25(4):191-5. PubMed ID: 21399466
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous compression plating for intertrochanteric fractures. Surgical technique, tips for surgery, and results.
    Peyser A; Weil Y; Liebergall M; Mosheiff R
    Oper Orthop Traumatol; 2005 Jun; 17(2):158-77. PubMed ID: 16007384
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The percutaneous compression plate versus the dynamic hip screw for treatment of intertrochanteric hip fractures: a systematic review and meta-analysis of comparative studies.
    Ma J; Xing D; Ma X; Xu W; Wang J; Chen Y; Song D
    Orthop Traumatol Surg Res; 2012 Nov; 98(7):773-83. PubMed ID: 23044466
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Percutaneous compression plate versus dynamic hip screw for treatment of intertrochanteric hip fractures: A overview of systematic reviews and update meta-analysis of randomized controlled trials.
    Long H; Lin Z; Lu B; Zhao R; Sun B; Cheng L; Zhao S; Zhu Y
    Int J Surg; 2016 Sep; 33 Pt A():1-7. PubMed ID: 27398689
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fixation of intertrochanteric hip fractures: gamma nail versus dynamic hip screw. A randomized, prospective study.
    O'Brien PJ; Meek RN; Blachut PA; Broekhuyse HM; Sabharwal S
    Can J Surg; 1995 Dec; 38(6):516-20. PubMed ID: 7497366
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparative outcome of PFNA, Gamma nails, PCCP, Medoff plate, LISS and dynamic hip screws for fixation in elderly trochanteric fractures: a systematic review and network meta-analysis of randomized controlled trials.
    Arirachakaran A; Amphansap T; Thanindratarn P; Piyapittayanun P; Srisawat P; Kongtharvonskul J
    Eur J Orthop Surg Traumatol; 2017 Oct; 27(7):937-952. PubMed ID: 28434124
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Locking plates increase the strength of dynamic hip screws.
    Jewell DP; Gheduzzi S; Mitchell MS; Miles AW
    Injury; 2008 Feb; 39(2):209-12. PubMed ID: 17880976
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical analysis of the percutaneous compression plate and sliding hip screw in intracapsular hip fractures: experimental assessment using synthetic and cadaver bones.
    Brandt E; Verdonschot N; van Vugt A; van Kampen A
    Injury; 2006 Oct; 37(10):979-83. PubMed ID: 16934259
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A meta-analysis of percutaneous compression plate versus sliding hip screw for the management of intertrochanteric fractures of the hip.
    Cheng T; Zhang GY; Liu T; Zhang XL
    J Trauma Acute Care Surg; 2012 May; 72(5):1435-43. PubMed ID: 22673279
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Minimally invasive percutaneous compression plating versus dynamic hip screw for intertrochanteric fractures: a randomized control trial.
    Cheng Q; Huang W; Gong X; Wang C; Liang X; Hu N
    Chin J Traumatol; 2014; 17(5):249-55. PubMed ID: 25293893
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Percutaneous compression plating (PCCP) versus the dynamic hip screw for pertrochanteric hip fractures: preliminary results.
    Brandt SE; Lefever S; Janzing HM; Broos PL; Pilot P; Houben BJ
    Injury; 2002 Jun; 33(5):413-8. PubMed ID: 12095721
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A meta-analysis of percutenous compression plate versus intramedullary nail for treatment of intertrochanteric HIP fractures.
    Shen J; Hu C; Yu S; Huang K; Xie Z
    Int J Surg; 2016 May; 29():151-8. PubMed ID: 27063859
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Research advance of dynamic hip screw internal fixation in treatment of intertrochanteric fractures].
    Li H; Zhang Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2005 Oct; 19(10):839-42. PubMed ID: 16274138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimally invasive screw plates for surgery of unstable intertrochanteric femoral fractures: a biomechanical comparative study.
    Ropars M; Mitton D; Skalli W
    Clin Biomech (Bristol, Avon); 2008 Oct; 23(8):1012-7. PubMed ID: 18579266
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimally invasive osteosynthesis in stable trochanteric fractures: a comparative study between Gotfried percutaneous compression plate and Gamma 3 intramedullary nail.
    Varela-Egocheaga JR; Iglesias-Colao R; Suárez-Suárez MA; Fernández-Villán M; González-Sastre V; Murcia-Mazón A
    Arch Orthop Trauma Surg; 2009 Oct; 129(10):1401-7. PubMed ID: 19672606
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The percutaneous compression plate (PCCP) in the treatment of trochanteric hip fractures in elderly patients.
    Bensafi H; Laffosse JM; Giordano G; Dao C; Chiron P; Puget J
    Acta Orthop Belg; 2006 Jun; 72(3):314-9. PubMed ID: 16889143
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A prospective, randomised study comparing the percutaneous compression plate and the compression hip screw for the treatment of intertrochanteric fractures of the hip.
    Peyser A; Weil YA; Brocke L; Sela Y; Mosheiff R; Mattan Y; Manor O; Liebergall M
    J Bone Joint Surg Br; 2007 Sep; 89(9):1210-7. PubMed ID: 17905960
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous compression plate versus dynamic hip screw for treatment of intertrochanteric Hip fractures: a meta-analyse of five randomized controlled trials.
    Zhang L; Shen J; Yu S; Huang Q; Xie Z
    ScientificWorldJournal; 2014; 2014():512512. PubMed ID: 24737975
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.