These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
145 related articles for article (PubMed ID: 18411601)
1. Achieving the required medial offset and limb length in total hip arthroplasty. Lakshmanan P; Ahmed SM; Hansford RG; Woodnutt DJ Acta Orthop Belg; 2008 Feb; 74(1):49-53. PubMed ID: 18411601 [TBL] [Abstract][Full Text] [Related]
2. Interest of an intraoperative limb-length and offset measurement device in total hip arthroplasty. Barbier O; Ollat D; Versier G Orthop Traumatol Surg Res; 2012 Jun; 98(4):398-404. PubMed ID: 22560790 [TBL] [Abstract][Full Text] [Related]
3. Determining and Achieving Target Limb Length and Offset in Total Hip Arthroplasty Using Intraoperative Digital Radiography. Debbi EM; Rajaee SS; Mayeda BF; Penenberg BL J Arthroplasty; 2020 Mar; 35(3):779-785. PubMed ID: 31699530 [TBL] [Abstract][Full Text] [Related]
4. Accurate limb-length equalization during total hip arthroplasty. Bose WJ Orthopedics; 2000 May; 23(5):433-6. PubMed ID: 10825109 [TBL] [Abstract][Full Text] [Related]
5. [Confrontation of the radiographic preoperative planning with the postoperative data for uncemented total hip arthroplasty]. Debarge R; Lustig S; Neyret P; Ait Si Selmi T Rev Chir Orthop Reparatrice Appar Mot; 2008 Jun; 94(4):368-75. PubMed ID: 18555863 [TBL] [Abstract][Full Text] [Related]
6. [Clinical research of accurate limb length equalization in total hip arthroplasty]. Shao S; Fu K; Chen Y; Gao M; Ling S Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2010 May; 24(5):541-3. PubMed ID: 20540255 [TBL] [Abstract][Full Text] [Related]
7. Accuracy of leg length and femoral offset restoration after total hip arthroplasty with the utilisation of an intraoperative calibration gauge. Enke O; Levy YD; Bruce WJ Hip Int; 2020 May; 30(3):296-302. PubMed ID: 30924374 [TBL] [Abstract][Full Text] [Related]
8. Effect of preoperative limb-length discrepancy on abductor strength after total hip arthroplasty in patients with developmental dysplasia of the hip. Liu R; Li Y; Bai C; Song Q; Wang K Arch Orthop Trauma Surg; 2014 Jan; 134(1):113-9. PubMed ID: 24297213 [TBL] [Abstract][Full Text] [Related]
9. The intraoperative use of a calliper predicts leg length and offset after total hip arthroplasty. Component subsidence influences the leg length. Fansur M; Yurdi NA; Stoewe R J Orthop Surg Res; 2021 Jul; 16(1):424. PubMed ID: 34217347 [TBL] [Abstract][Full Text] [Related]
10. Biomechanical reconstruction of the hip: a randomised study comparing total hip resurfacing and total hip arthroplasty. Girard J; Lavigne M; Vendittoli PA; Roy AG J Bone Joint Surg Br; 2006 Jun; 88(6):721-6. PubMed ID: 16720762 [TBL] [Abstract][Full Text] [Related]
11. Significantly reduced leg length discrepancy and increased femoral offset by application of a head-neck adapter in revision total hip arthroplasty. Woelfle JV; Fraitzl CR; Reichel H; Wernerus D J Arthroplasty; 2014 Jun; 29(6):1301-7. PubMed ID: 24405617 [TBL] [Abstract][Full Text] [Related]
12. Novel method for ensuring leg length in total hip arthroplasty. Maratt JD; Weber AE; Knesek M; Lien JR; Urquhart AG Orthopedics; 2013 Apr; 36(4):e401-3. PubMed ID: 23590776 [TBL] [Abstract][Full Text] [Related]
13. The Exeter technique can lead to a lower incidence of leg-length discrepancy after total hip arthroplasty. Halai M; Gupta S; Gilmour A; Bharadwaj R; Khan A; Holt G Bone Joint J; 2015 Feb; 97-B(2):154-9. PubMed ID: 25628275 [TBL] [Abstract][Full Text] [Related]
14. Radiographic assessment of biomechanical parameters following hip resurfacing and cemented total hip arthroplasty. Robb C; Harris R; O'Dwyer K; Aslam N Hip Int; 2009; 19(3):251-6. PubMed ID: 19891051 [TBL] [Abstract][Full Text] [Related]
15. Can computer-assisted surgery help restore leg length and offset during THA? A continuous series of 321 cases. Clavé A; Sauleau V; Cheval D; Williams T; Lefèvre C; Stindel E Orthop Traumatol Surg Res; 2015 Nov; 101(7):791-5. PubMed ID: 26470801 [TBL] [Abstract][Full Text] [Related]
16. Digital templating facilitates accurate leg length correction in total hip arthroplasty. Jassim SS; Ingham C; Keeling M; Wimhurst JA Acta Orthop Belg; 2012 Jun; 78(3):344-9. PubMed ID: 22822575 [TBL] [Abstract][Full Text] [Related]
17. The association of leg length and offset reconstruction after total hip arthroplasty with clinical outcomes. Bolink SAAN; Lenguerrand E; Brunton LR; Hinds N; Wylde V; Heyligers IC; Blom AW; Whitehouse MR; Grimm B Clin Biomech (Bristol); 2019 Aug; 68():89-95. PubMed ID: 31177011 [TBL] [Abstract][Full Text] [Related]
18. Cementless total hip arthroplasty and limb-length equalization in patients with unilateral Crowe type-IV hip dislocation. Lai KA; Shen WJ; Huang LW; Chen MY J Bone Joint Surg Am; 2005 Feb; 87(2):339-45. PubMed ID: 15687157 [TBL] [Abstract][Full Text] [Related]
19. Reproduction of Hip Offset and Leg Length in Navigated Total Hip Arthroplasty: How Accurate Are We? Ellapparadja P; Mahajan V; Deakin AH; Deep K J Arthroplasty; 2015 Jun; 30(6):1002-7. PubMed ID: 25677938 [TBL] [Abstract][Full Text] [Related]
20. An intraoperative device to restore femoral offset in total hip arthroplasty. Xue E; Su Z; Chen C; Wong PK; Wen H; Zhang Y J Orthop Surg Res; 2014 Jul; 9():58. PubMed ID: 25037492 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]