These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 18412671)

  • 1. Newton valve: a word of caution.
    Paul V; Thomas R; Criswell J
    Anaesthesia; 2008 May; 63(5):560. PubMed ID: 18412671
    [No Abstract]   [Full Text] [Related]  

  • 2. Worn AC wire insulation on examination lights causes device failure and shock hazard.
    Health Devices; 2003 Jun; 32(6):241-3. PubMed ID: 12889261
    [No Abstract]   [Full Text] [Related]  

  • 3. The crying wolf: still crying?
    Imhoff M; Fried R
    Anesth Analg; 2009 May; 108(5):1382-3. PubMed ID: 19372311
    [No Abstract]   [Full Text] [Related]  

  • 4. Ventilator gas supply inlet filters.
    Health Devices; 2005 Dec; 34(12):425. PubMed ID: 16483130
    [No Abstract]   [Full Text] [Related]  

  • 5. Fresh gas decoupling valve failure precludes mechanical ventilation in a Draeger Fabius GS anesthesia machine.
    Ortega RA; Zambricki ER
    Anesth Analg; 2007 Apr; 104(4):1000; discussion 1000-1. PubMed ID: 17377130
    [No Abstract]   [Full Text] [Related]  

  • 6. Hazard report. Lethal risk: valve failure in Siemens 900 series ventilators can stop ventilation.
    Health Devices; 1999 Aug; 28(8):324-5. PubMed ID: 10456299
    [No Abstract]   [Full Text] [Related]  

  • 7. Modified testing procedure for manual resuscitators to minimize the risk of barotrauma resulting from a malfunctioning exhalation valve.
    Health Devices; 1995 Nov; 24(11):476-7. PubMed ID: 8750069
    [No Abstract]   [Full Text] [Related]  

  • 8. Ventilator pressure alarm line adaptor for the Penlon 200 fitted with a Newton valve.
    Kumar CM; Leech M; Wood K
    Anaesthesia; 1993 Jan; 48(1):90. PubMed ID: 8434773
    [No Abstract]   [Full Text] [Related]  

  • 9. Hazard report. Loose mounting screws on Cardinal Health Avea ventilator cart may cause cart to tip or collapse.
    Health Devices; 2009 Jun; 38(6):197-8. PubMed ID: 20848967
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Siemens Servo 300 ventilators: potentially dangerous failures can be avoided by following specified maintenance procedures.
    Health Devices; 2002 Apr; 31(4):151-2. PubMed ID: 11989069
    [No Abstract]   [Full Text] [Related]  

  • 11. [BEATE--a new function test instrument for safety technical assessment of respirators].
    Boenick U; Matzek F
    Biomed Tech (Berl); 1988 Nov; 33(11):271-4. PubMed ID: 3207818
    [No Abstract]   [Full Text] [Related]  

  • 12. Patient safety incidents associated with equipment in critical care: a review of reports to the UK National Patient Safety Agency.
    Thomas AN; Galvin I
    Anaesthesia; 2008 Nov; 63(11):1193-7. PubMed ID: 18803628
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Incorrectly sited PEEP valve.
    Brosnan C; Khoo K
    Anaesthesia; 2005 Apr; 60(4):418-9; discussion 419. PubMed ID: 15766357
    [No Abstract]   [Full Text] [Related]  

  • 14. Preventing a disconnection from the mechanical ventilator in long-term care settings: safety and client options.
    Siebert SJ
    SCI Nurs; 2001; 18(2):95-7. PubMed ID: 12035469
    [No Abstract]   [Full Text] [Related]  

  • 15. A new APL valve hazard.
    Sanders R
    Anaesthesia; 2001 Nov; 56(11):1119-20. PubMed ID: 11715955
    [No Abstract]   [Full Text] [Related]  

  • 16. A response to 'Checking anaesthetic equipment and the Expert Group on Blocked Anaesthetic Tubing (EGBAT)', Carter J A, Anaesthesia 2004; 59: 105-7.
    Marcus R
    Anaesthesia; 2004 May; 59(5):523. PubMed ID: 15096273
    [No Abstract]   [Full Text] [Related]  

  • 17. Expiratory valve and pediatric breathing system.
    Mahajan R; Grover VK; Kumar S
    Paediatr Anaesth; 2008 Apr; 18(4):352-3. PubMed ID: 18315659
    [No Abstract]   [Full Text] [Related]  

  • 18. Unnoticed alarms contribute to a death in an MRI suite.
    Health Devices; 2000 Sep; 29(9):338-40. PubMed ID: 11022318
    [No Abstract]   [Full Text] [Related]  

  • 19. How human factors lead to medical device adverse events.
    Rich S
    Nursing; 2008 Jun; 38(6):62-3. PubMed ID: 18497666
    [No Abstract]   [Full Text] [Related]  

  • 20. Avoiding airway obstruction.
    Mayne D
    Br J Anaesth; 2002 Apr; 88(4):609; author reply 609-10. PubMed ID: 12066749
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.