These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
195 related articles for article (PubMed ID: 18416747)
21. An investigation into the placement of force delivery systems and the initial forces applied by clinicians during space closure. Nattrass C; Ireland AJ; Sherriff M Br J Orthod; 1997 May; 24(2):127-31. PubMed ID: 9218110 [TBL] [Abstract][Full Text] [Related]
22. The Hybrid Orthodontic Treatment System (HOTS). Ikegami T; Wong RW; Hägg U; Lee W; Hibino K World J Orthod; 2010; 11(2):168-79. PubMed ID: 20552104 [TBL] [Abstract][Full Text] [Related]
23. Static frictional force and surface roughness of various bracket and wire combinations. Doshi UH; Bhad-Patil WA Am J Orthod Dentofacial Orthop; 2011 Jan; 139(1):74-9. PubMed ID: 21195280 [TBL] [Abstract][Full Text] [Related]
24. Experimental determination of optimal force system required for control of anterior tooth movement in sliding mechanics. Sia S; Shibazaki T; Koga Y; Yoshida N Am J Orthod Dentofacial Orthop; 2009 Jan; 135(1):36-41. PubMed ID: 19121498 [TBL] [Abstract][Full Text] [Related]
25. A randomized clinical trial to compare three methods of orthodontic space closure. Dixon V; Read MJ; O'Brien KD; Worthington HV; Mandall NA J Orthod; 2002 Mar; 29(1):31-6. PubMed ID: 11907307 [TBL] [Abstract][Full Text] [Related]
26. Choosing a pre-adjusted orthodontic appliance prescription for anterior teeth. Thickett E; Taylor NG; Hodge T J Orthod; 2007 Jun; 34(2):95-100. PubMed ID: 17545296 [TBL] [Abstract][Full Text] [Related]
27. Integrative orthodontics with the ribbon arch. White LW World J Orthod; 2004; 5(2):147-51. PubMed ID: 15615133 [TBL] [Abstract][Full Text] [Related]
28. A new orthodontic force system for moment control utilizing the flexibility of common wires: Evaluation of the effect of contractile force and hook length. Lai WJ; Midorikawa Y; Kanno Z; Takemura H; Suga K; Soga K; Ono T; Uo M J Formos Med Assoc; 2018 Jan; 117(1):71-79. PubMed ID: 28408197 [TBL] [Abstract][Full Text] [Related]
29. Comparing patient-centered outcomes and efficiency of space closure between nickel-titanium closed-coil springs and elastomeric power chains during orthodontic treatment. Badran SA; Al-Zaben JM; Al-Taie LM; Tbeishi H; Al-Omiri MK Angle Orthod; 2022 Jul; 92(4):471-477. PubMed ID: 35348615 [TBL] [Abstract][Full Text] [Related]
30. Simple "TRS" Auxiliary tube for retraction of anterior segment using segmental T loop mechanics. Shyagali TR; Rajpara Y; Trivedi K Int J Orthod Milwaukee; 2014; 25(1):31-3. PubMed ID: 24812739 [TBL] [Abstract][Full Text] [Related]
31. A comparison of the rate of space closure using a nickel-titanium spring and an elastic module: a clinical study. Samuels RH; Rudge SJ; Mair LH Am J Orthod Dentofacial Orthop; 1993 May; 103(5):464-7. PubMed ID: 8480716 [TBL] [Abstract][Full Text] [Related]
32. Innovative design of closing loops producing an optimal force system applicable in the 0.022-in bracket slot system. Sumi M; Koga Y; Tominaga JY; Hamanaka R; Ozaki H; Chiang PC; Yoshida N Am J Orthod Dentofacial Orthop; 2016 Dec; 150(6):968-978. PubMed ID: 27894546 [TBL] [Abstract][Full Text] [Related]
33. A comparison of space closure rates between preactivated nickel-titanium and titanium-molybdenum alloy T-loops: a randomized controlled clinical trial. Keng FY; Quick AN; Swain MV; Herbison P Eur J Orthod; 2012 Feb; 34(1):33-8. PubMed ID: 21415288 [TBL] [Abstract][Full Text] [Related]
34. Clinical efficiency of nonconventional elastomeric ligatures in the canine retraction phase of preadjusted edgewise appliance therapy: an in-vivo study. Dholakia KD; Bhat SR Am J Orthod Dentofacial Orthop; 2012 Jun; 141(6):715-22. PubMed ID: 22640673 [TBL] [Abstract][Full Text] [Related]
35. Forces in the presence of ceramic versus stainless steel brackets with unconventional vs conventional ligatures. Baccetti T; Franchi L; Camporesi M Angle Orthod; 2008 Jan; 78(1):120-4. PubMed ID: 18193950 [TBL] [Abstract][Full Text] [Related]
36. Control of anterior anchorage with miniscrews and sliding mechanics in an adolescent with missing second premolars: A clinical report with biomechanical validation. Giancotti A; Carillo M; Giancotti L; Pachì F Int Orthod; 2024 Sep; 22(3):100895. PubMed ID: 38991251 [TBL] [Abstract][Full Text] [Related]
38. Can we close large prosthetic space with orthodontics? Mesko ME; Skupien JA; Valentini F; Pereira-Cenci T Int J Orthod Milwaukee; 2013; 24(3):41-4. PubMed ID: 24358658 [TBL] [Abstract][Full Text] [Related]
39. The use of titanium miniscrews for molar protraction in extraction treatment. Giancotti A; Greco M; Mampieri G; Arcuri C Prog Orthod; 2004; 5(2):236-47. PubMed ID: 15546014 [TBL] [Abstract][Full Text] [Related]
40. A segmented appliance for space closure followed by Invisalign and fixed appliances. Uribe F; Cutrera A; Nanda R Orthodontics (Chic.); 2011; 12(4):386-95. PubMed ID: 22299111 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]