These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 1842271)

  • 1. High-frequency audiometry. Accelerometric findings with electric bone-conduction audiometry.
    Löppönen H; Laitakari K; Sorri M
    Scand Audiol; 1991; 20(1):61-7. PubMed ID: 1842271
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-frequency air-conduction and electric bone-conduction audiometry. Comparison of two methods.
    Löppönen H; Sorri M
    Scand Audiol; 1991; 20(3):175-80. PubMed ID: 1842286
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-frequency audiometry. Masking in electric bone-conduction audiometry.
    Löppönen H
    Scand Audiol; 1992; 21(1):31-5. PubMed ID: 1585128
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High-frequency air-conduction and electric bone-conduction audiometry. Age and sex variations.
    Löppönen H; Sorri M; Bloigu R
    Scand Audiol; 1991; 20(3):181-9. PubMed ID: 1842287
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcranial attenuation of bone-conducted sound when stimulation is at the mastoid and at the bone conduction hearing aid position.
    Stenfelt S
    Otol Neurotol; 2012 Feb; 33(2):105-14. PubMed ID: 22193619
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Vibrotactile Thresholds on the Mastoid and Forehead Position of Deaf Patients Using Radioear B71 and B81.
    Fredén Jansson KJ; Håkansson B; Reinfeldt S; Fröhlich L; Rahne T
    Ear Hear; 2017; 38(6):714-723. PubMed ID: 28737551
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The estimation of hearing threshold for high frequencies in children from the Upper Silesia].
    Gierek T; Klimczak-Gołab L; Majzel K; Zbrowska-Bielska D
    Otolaryngol Pol; 2002; 56(3):345-52. PubMed ID: 12162025
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bone conduction thresholds and skull vibration measured on the teeth during stimulation at different sites on the human head.
    Ito T; Röösli C; Kim CJ; Sim JH; Huber AM; Probst R
    Audiol Neurootol; 2011; 16(1):12-22. PubMed ID: 20453499
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transmission of bone conducted sound - correlation between hearing perception and cochlear vibration.
    Eeg-Olofsson M; Stenfelt S; Taghavi H; Reinfeldt S; Håkansson B; Tengstrand T; Finizia C
    Hear Res; 2013 Dec; 306():11-20. PubMed ID: 24047594
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computerized in-situ test for bone conduction hearing aids.
    Laitakari K; Jämsä T
    Scand Audiol Suppl; 2001; (52):79-80. PubMed ID: 11318491
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An experimental objective method to determine maximum output and dynamic range of an active bone conduction implant: the Bonebridge.
    Mertens G; Desmet J; Snik AF; Van de Heyning P
    Otol Neurotol; 2014 Aug; 35(7):1126-30. PubMed ID: 24662632
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Examination of bone-conducted transmission from sound field excitation measured by thresholds, ear-canal sound pressure, and skull vibrations.
    Reinfeldt S; Stenfelt S; Good T; Håkansson B
    J Acoust Soc Am; 2007 Mar; 121(3):1576-87. PubMed ID: 17407895
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-frequency monitoring using an electrostimulation audiometer.
    Thornton AR; Bell IE; Phillipps JJ
    Br J Audiol; 1989 Feb; 23(1):63-8. PubMed ID: 2706409
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of bone-conduction harmonic distortions on hearing thresholds.
    Eichenauer A; Dillon H; Clinch B; Loi T
    J Acoust Soc Am; 2014 Aug; 136(2):EL96-102. PubMed ID: 25096153
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thresholds to soft tissue conduction stimulation compared to bone conduction stimulation.
    Adelman C; Sohmer H
    Audiol Neurootol; 2013; 18(1):31-5. PubMed ID: 23075479
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bone-conducted auditory brainstem-evoked responses and skull vibratory velocity measurement in rats at frequencies of 0.5-30 kHz with a new giant magnetostrictive bone conduction transducer.
    Sakai Y; Karino S; Kaga K
    Acta Otolaryngol; 2006 Sep; 126(9):926-33. PubMed ID: 16864489
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization and Clinical Use of Bone Conduction Transducers at Extended High Frequencies.
    Remenschneider AK; Cheng JT; Herrmann BS; Rosowski JJ
    Hear Res; 2023 Mar; 429():108688. PubMed ID: 36628803
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Estimation of bone conduction skull transmission by hearing thresholds and ear-canal sound pressure.
    Reinfeldt S; Stenfelt S; Håkansson B
    Hear Res; 2013 May; 299():19-28. PubMed ID: 23422311
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-frequency audiometry. Response characteristics of the KH70 vibrator.
    Hallmo P; Sundby A; Mair IW
    Scand Audiol; 1991; 20(2):139-43. PubMed ID: 1842279
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fixed-Level Frequency Threshold Testing for Ototoxicity Monitoring.
    Rieke CC; Clavier OH; Allen LV; Anderson AP; Brooks CA; Fellows AM; Brungart DS; Buckey JC
    Ear Hear; 2017; 38(6):e369-e375. PubMed ID: 28362673
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.