These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 18424879)

  • 1. EDR-2 film response to charged particles.
    Moyers MF
    Phys Med Biol; 2008 May; 53(10):N165-73. PubMed ID: 18424879
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams.
    Ahmad M; Chen Z; Song H; Deng J; Nath R
    Radiat Prot Dosimetry; 2006; 120(1-4):159-62. PubMed ID: 16644932
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Schwarzschild effect of the dosimetry film Kodak EDR 2.
    Djouguela A; Kollhoff R; Rubach A; Harder D; Poppe B
    Phys Med Biol; 2005 Nov; 50(21):N317-21. PubMed ID: 16237231
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The response of Kodak EDR2 film in high-energy electron beams.
    Gerbi BJ; Dimitroyannis DA
    Med Phys; 2003 Oct; 30(10):2703-5. PubMed ID: 14596308
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Film dosimetry for fluoroscopic procedures: potential errors.
    Morrell RE; Rogers AT
    Radiat Prot Dosimetry; 2005; 114(1-3):147-9. PubMed ID: 15933097
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A method of dosimetry for synchrotron microbeam radiation therapy using radiochromic films of different sensitivity.
    Crosbie JC; Svalbe I; Midgley SM; Yagi N; Rogers PA; Lewis RA
    Phys Med Biol; 2008 Dec; 53(23):6861-77. PubMed ID: 19001701
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Physical mechanism of the Schwarzschild effect in film dosimetry--theoretical model and comparison with experiments.
    Djouguela A; Kollhoff R; Rühmann A; Willborn KC; Harder D; Poppe B
    Phys Med Biol; 2006 Sep; 51(17):4345-56. PubMed ID: 16912385
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Practical and dosimetric implications of a new type of packaging for radiographic film.
    Gillis S; De Wagter C
    Phys Med Biol; 2005 Apr; 50(8):N63-72. PubMed ID: 15815085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetry characteristics of GAFCHROMIC EBT film responding to therapeutic electron beams.
    Su FC; Liu Y; Stathakis S; Shi C; Esquivel C; Papanikolaou N
    Appl Radiat Isot; 2007 Oct; 65(10):1187-92. PubMed ID: 17590344
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
    Ferreira BC; Lopes MC; Capela M
    Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetry during mango irradiation using Gafchromic HD-810 film.
    Sharma SD; Chilkulwar RH; Kumar R
    Radiat Prot Dosimetry; 2009 Feb; 133(4):208-13. PubMed ID: 19324933
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of uncertainties in Gafchromic EBT film dosimetry of photon beams.
    Martisíková M; Ackermann B; Jäkel O
    Phys Med Biol; 2008 Dec; 53(24):7013-27. PubMed ID: 19015581
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characteristics of sensitometric curves of radiographic films.
    Zhu XR; Yoo S; Jursinic PA; Grimm DF; Lopez F; Rownd JJ; Gillin MT
    Med Phys; 2003 May; 30(5):912-9. PubMed ID: 12773000
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of processor temperature on film dosimetry.
    Srivastava SP; Das IJ
    Med Dosim; 2012; 37(2):138-9. PubMed ID: 21925862
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetry intercomparison using a 35-keV X-ray synchrotron beam.
    Oves SD; Hogstrom KR; Ham K; Sajo E; Dugas JP
    Eur J Radiol; 2008 Dec; 68(3 Suppl):S121-5. PubMed ID: 18586431
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Calculation of the x-ray film response to heavy charged particle irradiation.
    Spielberger B; Scholz M; Krämer M; Kraft G
    Phys Med Biol; 2002 Nov; 47(22):4107-20. PubMed ID: 12476985
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Useful optical density range in film dosimetry: limitations due to noise and saturation.
    González-López A
    Phys Med Biol; 2007 Aug; 52(15):N321-7. PubMed ID: 17634633
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of film response to electron beams using a laser scanner system developed in the laboratory.
    San YT; Kandaiya S; Sing CL
    Appl Radiat Isot; 2005 Oct; 63(4):437-42. PubMed ID: 16051493
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The use of radiochromic films to measure and analyze the beam profile of charged particle accelerators.
    Avila-Rodriguez MA; Wilson JS; McQuarrie SA
    Appl Radiat Isot; 2009 Nov; 67(11):2025-8. PubMed ID: 19054679
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The value and limitations of dosimetry by the use of film in cobalt 60 beams (author's transl)].
    Ambonville A; Marinello G
    J Radiol; 1979 Nov; 60(11):701-6. PubMed ID: 529222
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.