These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 18429204)

  • 1. Ion-exchange chromatography.
    Williams A; Frasca V
    Curr Protoc Protein Sci; 2001 May; Chapter 8():Unit8.2. PubMed ID: 18429204
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Chromatofocusing of peptides and proteins using linear pH gradients formed on strong ion-exchange adsorbents.
    Kang X; Frey DD
    Biotechnol Bioeng; 2004 Aug; 87(3):376-87. PubMed ID: 15281112
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Theory and applications of a novel ion exchange chromatographic technology using controlled pH gradients for separating proteins on anionic and cationic stationary phases.
    Tsonev LI; Hirsh AG
    J Chromatogr A; 2008 Jul; 1200(2):166-82. PubMed ID: 18554604
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Systematic interpolation method predicts protein chromatographic elution with salt gradients, pH gradients and combined salt/pH gradients.
    Creasy A; Barker G; Carta G
    Biotechnol J; 2017 Mar; 12(3):. PubMed ID: 27992113
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Modeling of salt and pH gradient elution in ion-exchange chromatography.
    Schmidt M; Hafner M; Frech C
    J Sep Sci; 2014 Jan; 37(1-2):5-13. PubMed ID: 24415551
    [TBL] [Abstract][Full Text] [Related]  

  • 6. pH-gradient ion-exchange chromatography: an analytical tool for design and optimization of protein separations.
    Ahamed T; Nfor BK; Verhaert PD; van Dedem GW; van der Wielen LA; Eppink MH; van de Sandt EJ; Ottens M
    J Chromatogr A; 2007 Sep; 1164(1-2):181-8. PubMed ID: 17673242
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Induced binding of proteins by ammonium sulfate in affinity and ion-exchange column chromatography.
    Arakawa T; Tsumoto K; Ejima D; Kita Y; Yonezawa Y; Tokunaga M
    J Biochem Biophys Methods; 2007 Apr; 70(3):493-8. PubMed ID: 17210183
    [TBL] [Abstract][Full Text] [Related]  

  • 8. pH-based cation exchange chromatography in the capture and elution of monoclonal antibodies.
    Ng PK; Snyder MA
    J Sep Sci; 2012 Jan; 35(1):29-35. PubMed ID: 22125292
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of a chromatography model with linear gradient elution experimental data to the rapid scale-up in ion-exchange process chromatography of proteins.
    Ishihara T; Kadoya T; Yamamoto S
    J Chromatogr A; 2007 Aug; 1162(1):34-40. PubMed ID: 17399733
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A fully automated 2-D LC-MS method utilizing online continuous pH and RP gradients for global proteome analysis.
    Zhou H; Dai J; Sheng QH; Li RX; Shieh CH; Guttman A; Zeng R
    Electrophoresis; 2007 Dec; 28(23):4311-9. PubMed ID: 17987634
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Application of linear pH gradients for the modeling of ion exchange chromatography: Separation of monoclonal antibody monomer from aggregates.
    Kluters S; Wittkopp F; Jöhnck M; Frech C
    J Sep Sci; 2016 Feb; 39(4):663-75. PubMed ID: 26549715
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Weak cation-exchange monolithic column for capillary liquid chromatography of peptides and proteins.
    Chen X; Tolley HD; Lee ML
    J Sep Sci; 2011 Aug; 34(16-17):2063-71. PubMed ID: 25525657
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cation exchange displacement batch chromatography of proteins guided by screening of protein purification parameters.
    Kotasińska M; Richter V; Thiemann J; Schlüter H
    J Sep Sci; 2012 Nov; 35(22):3170-6. PubMed ID: 22707445
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monolithic capillary columns synthesized from a single phosphate-containing dimethacrylate monomer for cation-exchange chromatography of peptides and proteins.
    Chen X; Tolley HD; Lee ML
    J Chromatogr A; 2011 Jul; 1218(28):4322-31. PubMed ID: 21652040
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization of unstable ion-exchange chromatographic separation of proteins.
    Yamamoto S; Watler PK; Feng D; Kaltenbrunner O
    J Chromatogr A; 1999 Aug; 852(1):37-41. PubMed ID: 10480228
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Water on hydrophobic surfaces: Mechanistic modeling of hydrophobic interaction chromatography.
    Wang G; Hahn T; Hubbuch J
    J Chromatogr A; 2016 Sep; 1465():71-8. PubMed ID: 27575919
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Systematic generation of buffer systems for pH gradient ion exchange chromatography and their application.
    Kröner F; Hubbuch J
    J Chromatogr A; 2013 Apr; 1285():78-87. PubMed ID: 23489486
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Integrated system for temperature-controlled fast protein liquid chromatography comprising improved copolymer modified beaded agarose adsorbents and a travelling cooling zone reactor arrangement.
    Müller TK; Cao P; Ewert S; Wohlgemuth J; Liu H; Willett TC; Theodosiou E; Thomas OR; Franzreb M
    J Chromatogr A; 2013 Apr; 1285():97-109. PubMed ID: 23481470
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Charge heterogeneity profiling of monoclonal antibodies using low ionic strength ion-exchange chromatography and well-controlled pH gradients on monolithic columns.
    Talebi M; Nordborg A; Gaspar A; Lacher NA; Wang Q; He XZ; Haddad PR; Hilder EF
    J Chromatogr A; 2013 Nov; 1317():148-54. PubMed ID: 24011724
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Unfolding and aggregation of a glycosylated monoclonal antibody on a cation exchange column. Part I. Chromatographic elution and batch adsorption behavior.
    Guo J; Zhang S; Carta G
    J Chromatogr A; 2014 Aug; 1356():117-28. PubMed ID: 25015241
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.