BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

383 related articles for article (PubMed ID: 18431217)

  • 1. Current utilization of continuous end-tidal carbon dioxide monitoring in pediatric emergency departments.
    Langhan ML; Chen L
    Pediatr Emerg Care; 2008 Apr; 24(4):211-3. PubMed ID: 18431217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous end-tidal carbon dioxide monitoring in pediatric intensive care units.
    Langhan M
    J Crit Care; 2009 Jun; 24(2):227-30. PubMed ID: 19327292
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous end-tidal carbon dioxide monitoring for confirmation of endotracheal tube placement is neither widely available nor consistently applied by emergency physicians.
    Deiorio NM
    Emerg Med J; 2005 Jul; 22(7):490-3. PubMed ID: 15983084
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effectiveness of out-of-hospital use of continuous end-tidal carbon dioxide monitoring on the rate of unrecognized misplaced intubation within a regional emergency medical services system.
    Silvestri S; Ralls GA; Krauss B; Thundiyil J; Rothrock SG; Senn A; Carter E; Falk J
    Ann Emerg Med; 2005 May; 45(5):497-503. PubMed ID: 15855946
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Capnography: a valuable tool for airway management.
    Nagler J; Krauss B
    Emerg Med Clin North Am; 2008 Nov; 26(4):881-97, vii. PubMed ID: 19059088
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Capnography: beyond the numbers.
    Rhoades C; Thomas F
    Air Med J; 2002; 21(2):43-8. PubMed ID: 11896372
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous non-invasive end-tidal CO2 monitoring in pediatric inpatients with diabetic ketoacidosis.
    Agus MS; Alexander JL; Mantell PA
    Pediatr Diabetes; 2006 Aug; 7(4):196-200. PubMed ID: 16911005
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tracheal intubation practice and maintaining skill competency: survey of pediatric emergency department medical directors.
    Losek JD; Olson LR; Dobson JV; Glaeser PW
    Pediatr Emerg Care; 2008 May; 24(5):294-9. PubMed ID: 18496112
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Availability and clinical utilization of capnography in the prehospital setting.
    Langhan M
    Conn Med; 2011 Apr; 75(4):197-201. PubMed ID: 21560724
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does end-tidal carbon dioxide monitoring detect respiratory events prior to current sedation monitoring practices?
    Burton JH; Harrah JD; Germann CA; Dillon DC
    Acad Emerg Med; 2006 May; 13(5):500-4. PubMed ID: 16569750
    [TBL] [Abstract][Full Text] [Related]  

  • 11. End-tidal carbon dioxide monitoring in pediatrics - clinical applications.
    Bhende MS
    J Postgrad Med; 2001; 47(3):215-8. PubMed ID: 11832630
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pediatric preparedness of US emergency departments: a 2003 survey.
    Gausche-Hill M; Schmitz C; Lewis RJ
    Pediatrics; 2007 Dec; 120(6):1229-37. PubMed ID: 18055671
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficacy of the FEF colorimetric end-tidal carbon dioxide detector in children.
    Kelly JS; Wilhoit RD; Brown RE; James R
    Anesth Analg; 1992 Jul; 75(1):45-50. PubMed ID: 1616161
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bedside ultrasound in pediatric emergency medicine fellowship programs in the United States: little formal training.
    Ramirez-Schrempp D; Dorfman DH; Tien I; Liteplo AS
    Pediatr Emerg Care; 2008 Oct; 24(10):664-7. PubMed ID: 19242134
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sidestream end-tidal carbon dioxide monitoring during helicopter transport.
    Price DD; Wilson SR; Fee ME
    Air Med J; 2007; 26(1):55-9. PubMed ID: 17210495
    [TBL] [Abstract][Full Text] [Related]  

  • 16. End-tidal carbon dioxide measurements in children with acute asthma.
    Guthrie BD; Adler MD; Powell EC
    Acad Emerg Med; 2007 Dec; 14(12):1135-40. PubMed ID: 18045887
    [TBL] [Abstract][Full Text] [Related]  

  • 17. End tidal carbon dioxide monitoring in spontaneously breathing, nonintubated patients. A clinical comparison between conventional sidestream and microstream capnometers.
    Casati A; Gallioli G; Passaretta R; Scandroglio M; Bignami E; Torri G
    Minerva Anestesiol; 2001 Apr; 67(4):161-4. PubMed ID: 11376503
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Availability of pediatric services and equipment in emergency departments: United States, 2002-03.
    Middleton KR; Burt CW
    Adv Data; 2006 Feb; (367):1-16. PubMed ID: 16544808
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Need for standardized sign-out in the emergency department: a survey of emergency medicine residency and pediatric emergency medicine fellowship program directors.
    Sinha M; Shriki J; Salness R; Blackburn PA
    Acad Emerg Med; 2007 Feb; 14(2):192-6. PubMed ID: 17192443
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A simple, disposable end-tidal carbon dioxide detector.
    Rosenberg M; Block CS
    Anesth Prog; 1991; 38(1):24-6. PubMed ID: 1809050
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.