  • 1. Hemodialysis dialyzers contribute to contamination of air microemboli that bypass the alarm system in the air trap.
    Stegmayr C; Jonsson P; Forsberg U; Stegmayr B
    Int J Artif Organs; 2008 Apr; 31(4):317-22. PubMed ID: 18432587
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of air micro bubbles in the venous outlet line: an in vitro analysis of various air traps used for hemodialysis.
    Stegmayr CJ; Jonsson P; Forsberg U; Stegmayr BG
    Artif Organs; 2007 Jun; 31(6):483-8. PubMed ID: 17537063
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A high blood level in the venous chamber and a wet-stored dialyzer help to reduce exposure for microemboli during hemodialysis.
    Forsberg U; Jonsson P; Stegmayr C; Jonsson F; Nilsson B; Nilsson Ekdahl K; Stegmayr B
    Hemodial Int; 2013 Oct; 17(4):612-7. PubMed ID: 23627921
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Formation of Blood Foam in the Air Trap During Hemodialysis Due to Insufficient Automatic Priming of Dialyzers.
    Jonsson P; Lindmark L; Axelsson J; Karlsson L; Lundberg L; Stegmayr B
    Artif Organs; 2018 May; 42(5):533-539. PubMed ID: 29542180
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Air bubbles pass the security system of the dialysis device without alarming.
    Jonsson P; Karlsson L; Forsberg U; Gref M; Stegmayr C; Stegmayr B
    Artif Organs; 2007 Feb; 31(2):132-9. PubMed ID: 17298402
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Acoustical bubble trapper applied to hemodialysis.
    Palanchon P; Birmelé B; Tranquart F
    Ultrasound Med Biol; 2008 Apr; 34(4):681-4. PubMed ID: 17996355
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The sensor in the venous chamber does not prevent passage of air bubbles during hemodialysis.
    Stegmayr B; Forsberg U; Jonsson P; Stegmayr C
    Artif Organs; 2007 Feb; 31(2):162-6. PubMed ID: 17298408
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A high blood level in the air trap reduces microemboli during hemodialysis.
    Forsberg U; Jonsson P; Stegmayr C; Stegmayr B
    Artif Organs; 2012 Jun; 36(6):525-9. PubMed ID: 22360799
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effectiveness of microbubble removal in an airtrap with a free surface interface.
    Keshavarzi G; Simmons A; Yeoh G; Barber T
    J Biomech; 2015 May; 48(7):1237-40. PubMed ID: 25841295
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro investigations of citrate clearance with different dialysis filters.
    Hartmann J; Strobl K; Fichtinger U; Schildböck C; Falkenhagen D
    Int J Artif Organs; 2012 May; 35(5):352-9. PubMed ID: 22466998
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ex vivo testing of the Quart arterial line filter.
    Mueller XM; Tevaearai HT; Jegger D; Augstburger M; Burki M; von Segesser LK
    Perfusion; 1999 Nov; 14(6):481-7. PubMed ID: 10585156
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Venous chambers in clinical use for hemodialysis have limited capacity to eliminate microbubbles from entering the return bloodline: An in vitro study.
    Jonsson P; Stegmayr C; Stegmayr B; Forsberg U
    Artif Organs; 2023 Jun; 47(6):961-970. PubMed ID: 36594759
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assisted venous drainage, venous air, and gaseous microemboli transmission into the arterial line: an in-vitro study.
    Rider SP; Simon LV; Rice BJ; Poulton CC
    J Extra Corpor Technol; 1998 Dec; 30(4):160-5. PubMed ID: 10537575
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Air Transmission Comparison of the Affinity Fusion Oxygenator with an Integrated Arterial Filter to the Affinity NT Oxygenator with a Separate Arterial Filter.
    Potger KC; McMillan D; Ambrose M
    J Extra Corpor Technol; 2014 Sep; 46(3):229-38. PubMed ID: 26357789
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficiency of an air filter at the drainage site in a closed circuit with a centrifugal blood pump: an in vitro study.
    Mitsumaru A; Yozu R; Matayoshi T; Morita M; Shin H; Tsutsumi K; Iino Y; Kawada S
    ASAIO J; 2001; 47(6):692-5. PubMed ID: 11730213
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Technical characterization of dialysis fluid flow of newly developed dialyzers using mass transfer correlation equations.
    Kunikata S; Fukuda M; Yamamoto K; Yagi Y; Matsuda M; Sakai K
    ASAIO J; 2009; 55(3):231-5. PubMed ID: 19357496
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemodialysis machine air detectors need not detect microbubbles.
    Polaschegg HD
    Artif Organs; 2007 Dec; 31(12):911-2; author reply 913-4. PubMed ID: 18039272
    [No Abstract]   [Full Text] [Related]  

  • 18. Safety and performance of the Clearum™ high flux hemodialyzer.
    Krüger T; Dellanna F; Kleophas W; Flader O; McClure C; Caiazzo M; Manfredini S
    Artif Organs; 2024 Apr; 48(4):365-374. PubMed ID: 37962073
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Deairing of the venous drainage in standard extracorporeal circulation results in a profound reduction of arterial micro bubbles.
    Stock UA; Müller T; Bienek R; Krause H; Hartrumpf M; Albes J
    Thorac Cardiovasc Surg; 2006 Feb; 54(1):39-41. PubMed ID: 16485187
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Longer storage of dialyzers increases elution of poly(N-vinyl-2-pyrrolidone) from polysulfone-group dialysis membranes.
    Namekawa K; Kaneko A; Sakai K; Kunikata S; Matsuda M
    J Artif Organs; 2011 Mar; 14(1):52-7. PubMed ID: 21286768
    [TBL] [Abstract][Full Text] [Related]  