BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

432 related articles for article (PubMed ID: 18435265)

  • 1. [Study on design method for the individual anatomical hip joint endoprosthesis].
    Gong X; Kang L; Wang J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):92-6. PubMed ID: 18435265
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Finite element analysis of total hip replacement].
    Du X; Chen L; Xu G; Bao Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Apr; 26(2):429-32. PubMed ID: 19499818
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Finite element modeling of resurfacing hip prosthesis: estimation of accuracy through experimental validation.
    Taddei F; Martelli S; Gill HS; Cristofolini L; Viceconti M
    J Biomech Eng; 2010 Feb; 132(2):021002. PubMed ID: 20370239
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Finite element analysis of changes in femoral stresses after elite total hip arthroplasty].
    He RX; Luo YM; Yan SG; Wu HB
    Zhonghua Yi Xue Za Zhi; 2004 Sep; 84(18):1549-53. PubMed ID: 15500718
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mesh morphing for finite element analysis of implant positioning in cementless total hip replacements.
    Bah MT; Nair PB; Browne M
    Med Eng Phys; 2009 Dec; 31(10):1235-43. PubMed ID: 19744873
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A method of quantification of stress shielding in the proximal femur using hierarchical computational modeling.
    Be'ery-Lipperman M; Gefen A
    Comput Methods Biomech Biomed Engin; 2006 Feb; 9(1):35-44. PubMed ID: 16880155
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Three-dimensional finite element analysis of bone stress distribution around the hip joint prosthesis with stepped stem].
    Tan R; Fan H; Wu F; Chen J; Luo J; Zhang X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Aug; 28(4):732-6. PubMed ID: 21936371
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Strain adaptive bone remodelling: influence of the implantation technique.
    Behrens BA; Bouguecha A; Nolte I; Meyer-Lindenberg A; Stukenborg-Colsman C; Pressel T
    Stud Health Technol Inform; 2008; 133():33-44. PubMed ID: 18376011
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessments of different kinds of stems by experiments and FEM analysis: appropriate stress distribution on a hip prosthesis.
    Sakai R; Itoman M; Mabuchi K
    Clin Biomech (Bristol, Avon); 2006 Oct; 21(8):826-33. PubMed ID: 16701927
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Method for the evaluation of factors influencing the dislocation stability of total hip endoprotheses].
    Bader R; Scholz R; Steinhauser E; Busch R; Mittelmeier W
    Biomed Tech (Berl); 2004 May; 49(5):137-44. PubMed ID: 15212199
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of FE idealisation, load conditions and interface assumptions on the stress distribution and fatigue notch factor in the human femur with an endoprosthesis.
    Hedia HS; Barton DC; Fisher J; Elmidany TT
    Biomed Mater Eng; 1996; 6(3):135-52. PubMed ID: 8922259
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement.
    Kluess D; Martin H; Mittelmeier W; Schmitz KP; Bader R
    Med Eng Phys; 2007 May; 29(4):465-71. PubMed ID: 16901743
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Primary stability of an anatomical cementless hip stem: a statistical analysis.
    Viceconti M; Brusi G; Pancanti A; Cristofolini L
    J Biomech; 2006; 39(7):1169-79. PubMed ID: 15927191
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Load-shift--numerical evaluation of a new design philosophy for uncemented hip prostheses.
    Goetzen N; Lampe F; Nassut R; Morlock MM
    J Biomech; 2005 Mar; 38(3):595-604. PubMed ID: 15652559
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Design, production and clinical application of custom total hip prosthesis].
    Jiang T; Liu J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Apr; 22(2):392-5. PubMed ID: 15884563
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Geometric element analysis of fretting in a model of a modular femoral component of a hip implant.
    Lewis G
    Biomed Mater Eng; 2004; 14(1):43-51. PubMed ID: 14757952
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of the fixation stiffness of some femoral stems of different designs.
    Sakai R; Kanai N; Itoman M; Mabuchi K
    Clin Biomech (Bristol, Avon); 2006 May; 21(4):370-8. PubMed ID: 16431001
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Femoral strain changes after total hip arthroplasty--patient-specific finite element analyses 12 years after operation.
    Lengsfeld M; Burchard R; Günther D; Pressel T; Schmitt J; Leppek R; Griss P
    Med Eng Phys; 2005 Oct; 27(8):649-54. PubMed ID: 16139763
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.