These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 1843919)

  • 1. [Computer-assisted calibration of inductive plethysmography].
    Tomalak W; Willim G; Kapustianyk I; Hałuszka J
    Pneumonol Alergol Pol; 1991; 59(5-6):181-6. PubMed ID: 1843919
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Optoelectronic plethysmography -- a new technic to measure changes of chest wall volume].
    Skoczylas A; Sliwiński P
    Pneumonol Alergol Pol; 2007; 75(1):81-7. PubMed ID: 17541916
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Nonlinear model for estimating respiratory volume based on thoracoabdominal breathing movements.
    Raoufy MR; Hajizadeh S; Gharibzadeh S; Mani AR; Eftekhari P; Masjedi MR
    Respirology; 2013 Jan; 18(1):108-16. PubMed ID: 22897148
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Calibration of computer-assisted (Respicomp) respiratory inductive plethysmography in newborns.
    Warren RH; Alderson SH
    Am Rev Respir Dis; 1985 Apr; 131(4):564-7. PubMed ID: 3838868
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An assessment of pulmonary function testing and ventilatory kinematics by optoelectronic plethysmography.
    Layton AM; Garber CE; Basner RC; Bartels MN
    Clin Physiol Funct Imaging; 2011 Sep; 31(5):333-6. PubMed ID: 21771250
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of respiratory inductive plethysmography in estimating lung volume changes.
    Markhorst DG; van Genderingen HR
    Crit Care Med; 2004 May; 32(5):1241-2; author reply 1242. PubMed ID: 15190992
    [No Abstract]   [Full Text] [Related]  

  • 7. Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography.
    Lo WLA; Huang DF
    J Clin Monit Comput; 2017 Aug; 31(4):755-764. PubMed ID: 27289525
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of a new respiratory inductive plethysmograph.
    Leino K; Nunes S; Valta P; Takala J
    Acta Anaesthesiol Scand; 2001 Jan; 45(1):104-11. PubMed ID: 11152021
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Calibration of respiratory inductive plethysmography during quiet and active sleep in lambs.
    Warren RH; Fewell JE; Alderson SH
    J Dev Physiol; 1989 Dec; 12(6):347-52. PubMed ID: 2640229
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Respiratory inductive plethysmography to assess respiratory variability and complexity in humans.
    Fiamma MN; Samara Z; Baconnier P; Similowski T; Straus C
    Respir Physiol Neurobiol; 2007 May; 156(2):234-9. PubMed ID: 17251070
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Measuring accuracy of commercial respiratory function equipment and ventilation monitors for newborn infants].
    Hauschild M; Schmalisch G; Wauer RR
    Klin Padiatr; 1994; 206(3):167-74. PubMed ID: 8051910
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Passive partitioning of respiratory volumes and time constants in ventilated patients.
    Dall'Ava-Santucci J; Brunet F; Nouira S; Armaganidis A; Dhainaut JF; Monsallier JF; Lockhart A
    Eur Respir J; 1992 Sep; 5(8):1009-17. PubMed ID: 1426191
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Four methods of measuring tidal volume during high-frequency oscillatory ventilation.
    Hager DN; Fuld M; Kaczka DW; Fessler HE; Brower RG; Simon BA
    Crit Care Med; 2006 Mar; 34(3):751-7. PubMed ID: 16505661
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Acoustic plethysmography measures breathing in unrestrained neonatal mice.
    Daubenspeck JA; Li A; Nattie EE
    J Appl Physiol (1985); 2008 Jan; 104(1):262-8. PubMed ID: 17962574
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using LabVIEW to facilitate calibration and verification for respiratory impedance plethysmography.
    Ellis WS; Jones RT
    Comput Methods Programs Biomed; 1991 Dec; 36(4):169-75. PubMed ID: 1773604
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Age-dependent changes of airway obstruction parameters.
    Nosal S; Sutovska M; Nosalova G; Banovcin P; Sutovsky J; Franova S
    J Physiol Pharmacol; 2007 Nov; 58 Suppl 5(Pt 2):493-500. PubMed ID: 18204163
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Limitations of applicability of current calibration procedures for respiratory inductive plethysmography.
    Bellia V; Romano S; Sanci S; Bonsignore G
    Bull Eur Physiopathol Respir; 1984; 20(4):341-6. PubMed ID: 6478090
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the respiratory inductive plethysmograph in man.
    Guyatt AR; McBride MJ; Meanock CI
    Eur J Respir Dis; 1983 Feb; 64(2):81-9. PubMed ID: 6832253
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Therapeutic value of insufflation volume flow function in mechanical ventilation].
    Kliemann JU; Lippmann HG
    Biomed Tech (Berl); 1990; 35 Suppl 3():184-5. PubMed ID: 2078689
    [No Abstract]   [Full Text] [Related]  

  • 20. Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses.
    Schmalisch G; Schmidt M; Proquitté H; Foitzik B; Rüdiger M; Wauer RR
    Crit Care Med; 2003 May; 31(5):1435-41. PubMed ID: 12771615
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.