BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

50 related articles for article (PubMed ID: 18442694)

  • 21. The single-suture technique for anterior cruciate ligament graft preparation provides similar stability as a three-suture technique: a biomechanical in vitro study in a porcine model.
    Theopold J; Schleifenbaum S; Georgi A; Schmidt M; Henkelmann R; Osterhoff G; Hepp P
    Arch Orthop Trauma Surg; 2020 Apr; 140(4):511-516. PubMed ID: 31980876
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The buried knot technique for all inside graft link preparation leads to superior biomechanical graft link stability.
    Tiefenboeck TM; Hirtler L; Winnisch M; Binder H; Koch T; Komjati M; Hofbauer M; Ostermann RC
    Sci Rep; 2019 Feb; 9(1):1488. PubMed ID: 30728415
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Rotational Shortening of Collateral Ligament in TKR With Severe Deformity.
    Ku MC; Hwang YF; Cheng CK; Chen JK; Kumar A
    Tech Orthop; 2018 Dec; 33(4):274-278. PubMed ID: 30542231
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Biomechanical study of different suture methods in repairing tendon rupture].
    Hu Y; Jiang H; Li Q; Li J; Tang X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2017 Oct; 31(10):1208-1213. PubMed ID: 29806322
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanical Head-to-Head Comparison of 2 Sutures and the Giftbox Versus Bunnell Techniques for Midsubstance Achilles Tendon Ruptures.
    Van Dyke RO; Chaudhary SA; Gould G; Trimba R; Laughlin RT
    Orthop J Sports Med; 2017 May; 5(5):2325967117707477. PubMed ID: 28607938
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Do Needleless Knots have Similar Strength as the Krackow Suture? An In Vitro Porcine Tendon Study.
    Hong CK; Kuo TH; Yeh ML; Jou IM; Lin CL; Su WR
    Clin Orthop Relat Res; 2017 Feb; 475(2):552-557. PubMed ID: 27822894
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Features of human autologous hamstring graft elongation after pre-tensioning in anterior cruciate ligament reconstruction.
    Fujii M; Furumatsu T; Miyazawa S; Tanaka T; Inoue H; Kodama Y; Masuda K; Seno N; Ozaki T
    Int Orthop; 2016 Dec; 40(12):2553-2558. PubMed ID: 27695924
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A biomechanical comparison of the primary stability of two minimally invasive techniques for repair of ruptured Achilles tendon.
    Longo UG; Forriol F; Campi S; Maffulli N; Denaro V
    Knee Surg Sports Traumatol Arthrosc; 2012 Jul; 20(7):1392-7. PubMed ID: 22228376
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Achilles tendon rupture: avoiding tendon lengthening during surgical repair and rehabilitation.
    Maquirriain J
    Yale J Biol Med; 2011 Sep; 84(3):289-300. PubMed ID: 21966048
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Modified triple Kessler with least risk of elongation among Achilles tendon repair techniques: a systematic review and network meta-analysis of human cadaveric studies.
    Diniz P; Pacheco J; Fernandes RM; Pereira H; Castelo Ferreira F; Kerkhoffs GMMJ
    Knee Surg Sports Traumatol Arthrosc; 2023 May; 31(5):1644-1657. PubMed ID: 34089335
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Efficacy of repair techniques of the Achilles tendon: A meta-analysis of human cadaveric biomechanical studies.
    Yammine K; Assi C
    Foot (Edinb); 2017 Mar; 30():13-20. PubMed ID: 28171797
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Krackow locking stitch versus nonlocking premanufactured loop stitch for soft-tissue fixation: a biomechanical study.
    Deramo DM; White KL; Parks BG; Hinton RY
    Arthroscopy; 2008 May; 24(5):599-603. PubMed ID: 18442694
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The modified finger-trap suture technique: a biomechanical comparison of a novel suture technique for graft fixation.
    Su WR; Chu CH; Lin CL; Lin CJ; Jou IM; Chang CW
    Arthroscopy; 2012 May; 28(5):702-10. PubMed ID: 22261138
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Krackow locking stitch versus locking premanufactured loop stitch for soft-tissue fixation: a biomechanical study.
    White KL; Camire LM; Parks BG; Corey WS; Hinton RY
    Arthroscopy; 2010 Dec; 26(12):1662-6. PubMed ID: 20926231
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Biomechanical comparison of Krackow locking stitch versus nonlocking loop stitch with varying number of throws.
    Hahn JM; Inceoğlu S; Wongworawat MD
    Am J Sports Med; 2014 Dec; 42(12):3003-8. PubMed ID: 25269654
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The Krackow stitch: a biomechanical evaluation of changing the number of loops versus the number of sutures.
    McKeon BP; Heming JF; Fulkerson J; Langeland R
    Arthroscopy; 2006 Jan; 22(1):33-7. PubMed ID: 16399458
    [TBL] [Abstract][Full Text] [Related]  

  • 37.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 38.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 39.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 40.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 3.