These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
25. Patient-reported chronic pain after open inguinal hernia repair with lightweight or heavyweight mesh: a prospective, patient-reported outcomes study. Melkemichel M; Bringman S; Nilsson H; Widhe B Br J Surg; 2020 Nov; 107(12):1659-1666. PubMed ID: 32614470 [TBL] [Abstract][Full Text] [Related]
26. Sutureless fixation with fibrin glue of lightweight mesh in open inguinal hernia repair: effect on postoperative pain: a double-blind, randomized trial versus standard heavyweight mesh. Canonico S; Benevento R; Perna G; Guerniero R; Sciaudone G; Pellino G; Santoriello A; Selvaggi F Surgery; 2013 Jan; 153(1):126-30. PubMed ID: 22862902 [TBL] [Abstract][Full Text] [Related]
27. Critical evaluation of an innovative mesh for bilateral transabdominal preperitoneal (TAPP) repair of inguinal hernias. Köhler G; Fischer I; Kaltenböck R; Mitteregger M; Seitinger G; Szyszkowitz A Hernia; 2018 Oct; 22(5):857-862. PubMed ID: 29869074 [TBL] [Abstract][Full Text] [Related]
28. International guidelines for groin hernia management. HerniaSurge Group Hernia; 2018 Feb; 22(1):1-165. PubMed ID: 29330835 [TBL] [Abstract][Full Text] [Related]
29. Does primary closure of direct inguinal hernia defect during laparoscopic mesh repair reduce the risk of early recurrence? Ng AY; Lin J; Ching SS; Lee J; Wong ASY Hernia; 2020 Oct; 24(5):1093-1098. PubMed ID: 32638243 [TBL] [Abstract][Full Text] [Related]
30. Chronic pain after open inguinal hernia repair: expertise-based randomized clinical trial of heavyweight or lightweight mesh. Rutegård M; Lindqvist M; Svensson J; Nordin P; Haapamäki MM Br J Surg; 2021 Mar; 108(2):138-144. PubMed ID: 33711123 [TBL] [Abstract][Full Text] [Related]
31. Impact of polypropylene amount on functional outcome and quality of life after inguinal hernia repair by the TAPP procedure using pure, mixed, and titanium-coated meshes. Horstmann R; Hellwig M; Classen C; Röttgermann S; Palmes D World J Surg; 2006 Sep; 30(9):1742-9. PubMed ID: 16902744 [TBL] [Abstract][Full Text] [Related]
32. Long-term outcome and chronic pain in atraumatic fibrin glue versus staple fixation of extra light titanized meshes in laparoscopic inguinal hernia repair (TAPP): a single-center experience. Wirth U; Saller ML; von Ahnen T; Köckerling F; Schardey HM; Schopf S Surg Endosc; 2020 May; 34(5):1929-1938. PubMed ID: 31300910 [TBL] [Abstract][Full Text] [Related]
33. Utility of Magnetic Resonance Imaging to Monitor Surgical Meshes: Correlating Imaging and Clinical Outcome of Patients Undergoing Inguinal Hernia Repair. Hansen NL; Ciritsis A; Otto J; Busch D; Kuhl CK; Kraemer NA Invest Radiol; 2015 Jul; 50(7):436-42. PubMed ID: 25756683 [TBL] [Abstract][Full Text] [Related]
34. Standard polypropylene mesh vs lightweight mesh for Lichtenstein repair of primary inguinal hernia: a randomized controlled trial. Demetrashvili Z; Khutsishvili K; Pipia I; Kenchadze G; Ekaladze E Int J Surg; 2014 Dec; 12(12):1380-4. PubMed ID: 25448661 [TBL] [Abstract][Full Text] [Related]
35. BIOLAP: biological versus synthetic mesh in laparo-endoscopic inguinal hernia repair: study protocol for a randomized, multicenter, self-controlled clinical trial. Seefeldt CS; Meyer JS; Knievel J; Rieger A; Geißen R; Lefering R; Heiss MM Trials; 2019 Jan; 20(1):55. PubMed ID: 30651127 [TBL] [Abstract][Full Text] [Related]
36. Lightweight Versus Heavyweight Mesh in Laparoscopic Inguinal Hernia Repair: An Updated Systematic Review and Meta-Analysis of Randomized Trials. Hu D; Huang B; Gao L J Laparoendosc Adv Surg Tech A; 2019 Sep; 29(9):1152-1162. PubMed ID: 31373875 [No Abstract] [Full Text] [Related]
37. Prospective double-blind randomized controlled study comparing heavy- and lightweight polypropylene mesh in totally extraperitoneal repair of inguinal hernia: early results. Agarwal BB; Agarwal KA; Mahajan KC Surg Endosc; 2009 Feb; 23(2):242-7. PubMed ID: 18923870 [TBL] [Abstract][Full Text] [Related]
38. Mesh fixation with fibrin glue (Tissucol/Tisseel) in hernia repair dependent on the mesh structure--is there an optimum fibrin-mesh combination?--investigations on a biomechanical model. Schug-Pass C; Lippert H; Köckerling F Langenbecks Arch Surg; 2010 Jun; 395(5):569-74. PubMed ID: 19184090 [TBL] [Abstract][Full Text] [Related]
39. Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. O'Dwyer PJ; Kingsnorth AN; Molloy RG; Small PK; Lammers B; Horeyseck G Br J Surg; 2005 Feb; 92(2):166-70. PubMed ID: 15584057 [TBL] [Abstract][Full Text] [Related]
40. [Mesh shrinkage in hernia surgery: data from a prospective randomized double-blinded clinical study]. Langer C; Forster H; Konietschke F; Raab BW; Schaper A; Brunner E; Becker H Chirurg; 2010 Aug; 81(8):735-42, 744-5. PubMed ID: 20186380 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]