BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

604 related articles for article (PubMed ID: 18449032)

  • 1. Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique.
    Chang MC; Liu CL; Chen TH
    Spine (Phila Pa 1976); 2008 May; 33(10):E317-24. PubMed ID: 18449032
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Polymethylmethacrylate augmentation of cannulated pedicle screws for fixation in osteoporotic spines and comparison of its clinical results and biomechanical characteristics with the needle injection method.
    Chang MC; Kao HC; Ying SH; Liu CL
    J Spinal Disord Tech; 2013 Aug; 26(6):305-15. PubMed ID: 23887077
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surgical treatment of degenerative and traumatic spinal diseases with expandable screws in patients with osteoporosis: 2-year follow-up clinical study.
    Gazzeri R; Roperto R; Fiore C
    J Neurosurg Spine; 2016 Nov; 25(5):610-619. PubMed ID: 27314551
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation.
    Frankel BM; D'Agostino S; Wang C
    J Neurosurg Spine; 2007 Jul; 7(1):47-53. PubMed ID: 17633487
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of the degree of osteoporosis on the biomechanical anchoring strength of the sacral pedicle screws: an in vitro comparison between unaugmented bicortical screws and polymethylmethacrylate augmented unicortical screws.
    Zhuang XM; Yu BS; Zheng ZM; Zhang JF; Lu WW
    Spine (Phila Pa 1976); 2010 Sep; 35(19):E925-31. PubMed ID: 20098349
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength.
    Burval DJ; McLain RF; Milks R; Inceoglu S
    Spine (Phila Pa 1976); 2007 May; 32(10):1077-83. PubMed ID: 17471088
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws for the treatment of degenerative lumbar diseases with osteoporosis].
    Sun HL; Li CD; Yang ZC; Yi XD; Liu H; Lu HL; Li H; Wang Y
    Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Dec; 48(6):1019-1025. PubMed ID: 27987507
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical evaluation of a novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines.
    Paré PE; Chappuis JL; Rampersaud R; Agarwala AO; Perra JH; Erkan S; Wu C
    Spine (Phila Pa 1976); 2011 Aug; 36(18):E1210-4. PubMed ID: 21325986
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pedicle screw design and cement augmentation in osteoporotic vertebrae: effects of fenestrations and cement viscosity on fixation and extraction.
    Choma TJ; Pfeiffer FM; Swope RW; Hirner JP
    Spine (Phila Pa 1976); 2012 Dec; 37(26):E1628-32. PubMed ID: 22996264
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Effect and Safety of Polymethylmethacrylate-Augmented Sacral Pedicle Screws Applied in Osteoporotic Spine with Lumbosacral Degenerative Disease: A 2-Year Follow-up of 25 Patients.
    Guo HZ; Tang YC; Li YX; Yuan K; Guo DQ; Mo GY; Luo PJ; Zhou TP; Zhang SC; Liang D
    World Neurosurg; 2019 Jan; 121():e404-e410. PubMed ID: 30266711
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 cases.
    Amendola L; Gasbarrini A; Fosco M; Simoes CE; Terzi S; De Iure F; Boriani S
    J Orthop Traumatol; 2011 Dec; 12(4):193-9. PubMed ID: 22065147
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Segmental polymethylmethacrylate-augmented fenestrated pedicle screw fixation for lumbar spondylolisthesis in patients with osteoporosis - A case series and review of literature.
    Chandra VV; Prasad BC; Jagadeesh MA; Jayachandar V; Kumar SA; Kumar R
    Neurol India; 2017; 65(1):89-95. PubMed ID: 28084247
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical evaluation of a bone cement-injectable cannulated pedicle screw augmented with polymethylmethacrylate: 128 osteoporotic patients with 42 months of follow-up.
    Wang Z; Liu Y; Rong Z; Wang C; Liu X; Zhang F; Zhang Z; Xu J; Dai F
    Clinics (Sao Paulo); 2019; 74():e346. PubMed ID: 31188908
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical comparison of pedicle screw augmented with different volumes of polymethylmethacrylate in osteoporotic and severely osteoporotic cadaveric lumbar vertebrae: an experimental study.
    Liu D; Zhang B; Xie QY; Kang X; Zhou JJ; Wang CR; Lei W; Zheng W
    Spine J; 2016 Sep; 16(9):1124-32. PubMed ID: 27130374
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison between two pedicle screw augmentation instrumentations in adult degenerative scoliosis with osteoporosis.
    Xie Y; Fu Q; Chen ZQ; Shi ZC; Zhu XD; Wang CF; Li M
    BMC Musculoskelet Disord; 2011 Dec; 12():286. PubMed ID: 22188765
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Surgical treatment of osteoporotic thoracolumbar compressive fractures with open vertebral cement augmentation of expandable pedicle screw fixation: a biomechanical study and a 2-year follow-up of 20 patients.
    Wu ZX; Gao MX; Sang HX; Ma ZS; Cui G; Zhang Y; Lei W
    J Surg Res; 2012 Mar; 173(1):91-8. PubMed ID: 21067776
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polymethylmethacrylate augmentation of pedicle screws increases the initial fixation in osteoporotic spine patients.
    Sawakami K; Yamazaki A; Ishikawa S; Ito T; Watanabe K; Endo N
    J Spinal Disord Tech; 2012 Apr; 25(2):E28-35. PubMed ID: 22454185
    [TBL] [Abstract][Full Text] [Related]  

  • 18. PMMA-augmentation of incompletely cannulated pedicle screws: a cadaver study to determine the benefits in the osteoporotic spine.
    Goost H; Deborre C; Wirtz DC; Burger C; Prescher A; Fölsch C; Pflugmacher R; Kabir K
    Technol Health Care; 2014; 22(4):607-15. PubMed ID: 24837053
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new technique of bone cement augmentation via the disc space for percutaneous pedicle screw fixation.
    Park CK; Park CK; Lee DC; Lee DG
    J Neurosurg Spine; 2016 Jan; 24(1):16-9. PubMed ID: 26360145
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Direct reduction of thoracolumbar burst fractures by means of balloon kyphoplasty with calcium phosphate and stabilization with pedicle-screw instrumentation and fusion.
    Korovessis P; Repantis T; Petsinis G; Iliopoulos P; Hadjipavlou A
    Spine (Phila Pa 1976); 2008 Feb; 33(4):E100-8. PubMed ID: 18277858
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 31.