BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 18449158)

  • 1. Determination of depth and field size dependence of multileaf collimator transmission in intensity-modulated radiation therapy beams.
    Zygmanski P; Rosca F; Kadam D; Lorenz F; Nalichowski A; Court L; Chin L
    J Appl Clin Med Phys; 2007 Oct; 8(4):76-95. PubMed ID: 18449158
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A method for photon beam Monte Carlo multileaf collimator particle transport.
    Siebers JV; Keall PJ; Kim JO; Mohan R
    Phys Med Biol; 2002 Sep; 47(17):3225-49. PubMed ID: 12361220
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of static dosimetric leaf gap on MLC-based small-beam dose distribution for intensity-modulated radiosurgery.
    Lee JW; Choi KS; Hong S; Kim YL; Chung JB; Lee DH; Choe BY; Jang HS; Suh TS
    J Appl Clin Med Phys; 2007 Oct; 8(4):54-64. PubMed ID: 18449146
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An independent dose calculation algorithm for MLC-based radiotherapy including the spatial dependence of MLC transmission.
    Lorenz F; Nalichowski A; Rosca F; Killoran J; Wenz F; Zygmanski P
    Phys Med Biol; 2008 Feb; 53(3):557-73. PubMed ID: 18199902
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT.
    Yang Y; Xing L; Li JG; Palta J; Chen Y; Luxton G; Boyer A
    Med Phys; 2003 Nov; 30(11):2937-47. PubMed ID: 14655941
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and commissioning of a multileaf collimator model in monte carlo dose calculations for intensity-modulated radiation therapy.
    Jang SY; Vassiliev ON; Liu HH; Mohan R; Siebers JV
    Med Phys; 2006 Mar; 33(3):770-81. PubMed ID: 16878579
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Verification of a rounded leaf-end MLC model used in a radiotherapy treatment planning system.
    Williams MJ; Metcalfe P
    Phys Med Biol; 2006 Feb; 51(4):N65-78. PubMed ID: 16467576
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator.
    Kehwar TS; Bhardwaj AK; Chakarvarti SK
    J Appl Clin Med Phys; 2006 Aug; 7(3):43-54. PubMed ID: 17533348
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculation.
    Tyagi N; Moran JM; Litzenberg DW; Bielajew AF; Fraass BA; Chetty IJ
    Med Phys; 2007 Feb; 34(2):651-63. PubMed ID: 17388183
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Small field segments surrounded by large areas only shielded by a multileaf collimator: comparison of experiments and dose calculation.
    Kron T; Clivio A; Vanetti E; Nicolini G; Cramb J; Lonski P; Cozzi L; Fogliata A
    Med Phys; 2012 Dec; 39(12):7480-9. PubMed ID: 23231297
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spatial dependence of MLC transmission in IMRT delivery.
    Lorenz F; Nalichowski A; Rosca F; Kung J; Wenz F; Zygmanski P
    Phys Med Biol; 2007 Oct; 52(19):5985-99. PubMed ID: 17881814
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A practical method to calculate head scatter factors in wedged rectangular and irregular MLC shaped beams for external and internal wedges.
    Georg D; Olofsson J; Künzler T; Aiginger H; Karlsson M
    Phys Med Biol; 2004 Oct; 49(20):4689-700. PubMed ID: 15566168
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of an optimum photon beam model for head and-neck intensity-modulated radiotherapy.
    Webster GJ; Rowbottom CG; Mackay RI
    J Appl Clin Med Phys; 2007 Nov; 8(4):129-138. PubMed ID: 18449159
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analytic IMRT dose calculations utilizing Monte Carlo to predict MLC fluence modulation.
    Mihaylov IB; Lerma FA; Wu Y; Siebers JV
    Med Phys; 2006 Apr; 33(4):828-39. PubMed ID: 16696458
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator.
    Heath E; Seuntjens J
    Phys Med Biol; 2003 Dec; 48(24):4045-63. PubMed ID: 14727750
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of multileaf collimator leaf width on physical dose distributions in the treatment of CNS and head and neck neoplasms with intensity modulated radiation therapy.
    Fiveash JB; Murshed H; Duan J; Hyatt M; Caranto J; Bonner JA; Popple RA
    Med Phys; 2002 Jun; 29(6):1116-9. PubMed ID: 12094981
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system.
    MacKenzie MA; Lachaine M; Murray B; Fallone BG; Robinson D; Field GC
    J Appl Clin Med Phys; 2002; 3(2):97-109. PubMed ID: 11958650
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical evaluation of direct aperture optimization when applied to head-and-neck IMRT.
    Jones S; Williams M
    Med Dosim; 2008; 33(1):86-92. PubMed ID: 18262129
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimizing the MLC model parameters for IMRT in the RayStation treatment planning system.
    Chen S; Yi BY; Yang X; Xu H; Prado KL; D'Souza WD
    J Appl Clin Med Phys; 2015 Sep; 16(5):322–332. PubMed ID: 26699315
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric discrepancies caused by differing MLC parameters for dynamic IMRT.
    Wasbø E; Valen H
    Phys Med Biol; 2008 Jan; 53(2):405-15. PubMed ID: 18184995
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.