73 related articles for article (PubMed ID: 18450620)
1. A ten-year follow-up of the Reflection cementless acetabular component.
Civinini R; D'Arienzo M; Innocenti M
J Bone Joint Surg Br; 2008 May; 90(5):570-3. PubMed ID: 18450620
[TBL] [Abstract][Full Text] [Related]
2. Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up.
Zwartelé RE; Olsthoorn PG; Pöll RG; Brand R; Doets HC
Arch Orthop Trauma Surg; 2008 Dec; 128(12):1379-86. PubMed ID: 18758793
[TBL] [Abstract][Full Text] [Related]
3. Ten-year results after cementless THA with a sandwich-type alumina ceramic bearing.
Park YS; Park SJ; Lim SJ
Orthopedics; 2010 Nov; 33(11):796. PubMed ID: 21053885
[TBL] [Abstract][Full Text] [Related]
4. The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of age: a 12- to 16-year review.
Utting MR; Raghuvanshi M; Amirfeyz R; Blom AW; Learmonth ID; Bannister GC
J Bone Joint Surg Br; 2008 Nov; 90(11):1422-7. PubMed ID: 18978259
[TBL] [Abstract][Full Text] [Related]
5. [Total hip arthroplasty in patients under 40 years of age and, if indicated, reconstruction of acetabular defects with bone impaction grafting].
de Kam DC; Gardeniers JW; Veth RP; Schreurs BW
Ned Tijdschr Geneeskd; 2010; 154():A811. PubMed ID: 20482927
[TBL] [Abstract][Full Text] [Related]
6. Cementless acetabular socket revisions using Metasul metal-on-metal bearings.
Park KS; Yoon TR; Song EK; Lee KB
J Arthroplasty; 2010 Jun; 25(4):533-7. PubMed ID: 19493650
[TBL] [Abstract][Full Text] [Related]
7. Cementless hemispheric acetabular component for acetabular revision arthroplasty: a 5- to 19-year follow-up study.
Lian YY; Yoo MC; Pei FX; Kim KI; Chun SW; Cheng JQ
J Arthroplasty; 2008 Apr; 23(3):376-82. PubMed ID: 18358376
[TBL] [Abstract][Full Text] [Related]
8. The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement.
Ihle M; Mai S; Pfluger D; Siebert W
J Bone Joint Surg Br; 2008 Oct; 90(10):1284-90. PubMed ID: 18827236
[TBL] [Abstract][Full Text] [Related]
9. Long-term survivorship of cemented all-polyethylene acetabular components in patients > 75 years of age.
Levy BA; Berry DJ; Pagnano MW
J Arthroplasty; 2000 Jun; 15(4):461-7. PubMed ID: 10884206
[TBL] [Abstract][Full Text] [Related]
10. Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis.
Nieuwenhuis JJ; Malefijt Jde W; Hendriks JC; Gosens T; Bonnet M
Acta Orthop Belg; 2005 Jun; 71(3):294-302. PubMed ID: 16035702
[TBL] [Abstract][Full Text] [Related]
11. Long-term results of a hydroxyapatite-coated femoral component in total hip replacement: a 15- to 21-year follow-up study.
Rajaratnam SS; Jack C; Tavakkolizadeh A; George MD; Fletcher RJ; Hankins M; Shepperd JA
J Bone Joint Surg Br; 2008 Jan; 90(1):27-30. PubMed ID: 18160495
[TBL] [Abstract][Full Text] [Related]
12. [Long-term results of the Schenker cementless femoral component].
Dzupa V; Cech O; Sesták M; Klézl Z
Acta Chir Orthop Traumatol Cech; 2004; 71(2):93-100. PubMed ID: 15151096
[TBL] [Abstract][Full Text] [Related]
13. The bone-vacuum cementing technique for the fixation of the stem in total hip arthroplasty.
Pitto RP; Kessler M; Schikora N; di Muria GV
Chir Organi Mov; 2001; 86(2):99-110. PubMed ID: 12025052
[TBL] [Abstract][Full Text] [Related]
14. The medium-term results of the cemented Exeter femoral component in patients under 40 years of age.
de Kam DC; Klarenbeek RL; Gardeniers JW; Veth RP; Schreurs BW
J Bone Joint Surg Br; 2008 Nov; 90(11):1417-21. PubMed ID: 18978258
[TBL] [Abstract][Full Text] [Related]
15. Cementless acetabular fixation in patients 50 years and younger at 10 to 18 years of follow-up.
Teusink MJ; Callaghan JJ; Warth LC; Goetz DD; Pedersen DR; Johnston RC
J Arthroplasty; 2012 Aug; 27(7):1316-1323.e2. PubMed ID: 22266047
[TBL] [Abstract][Full Text] [Related]
16. Revision of the acetabulum with a contemporary cementless component.
Wysocki RW; Della Valle CJ; Shott S; Rosenberg AG; Berger RA; Galante JO
J Arthroplasty; 2009 Sep; 24(6 Suppl):58-63. PubMed ID: 19282138
[TBL] [Abstract][Full Text] [Related]
17. Circumferential osteotomy of the medial acetabular wall in total hip replacement for the late sequelae of childhood septic arthritis of the hip.
Lian YY; Yoo MC; Pei FX; Cho YJ; Cheng JQ; Chun SW
J Bone Joint Surg Br; 2007 Sep; 89(9):1149-54. PubMed ID: 17905949
[TBL] [Abstract][Full Text] [Related]
18. The angle-bore acetabular component and dislocation after revision of a failed total hip replacement.
Wroblewski BM; Siney PD; Fleming PA
J Bone Joint Surg Br; 2006 Feb; 88(2):184-7. PubMed ID: 16434521
[TBL] [Abstract][Full Text] [Related]
19. Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study.
Clement ND; Mitchell M; Trayner ME; Porter DE; Lawson GM; Burnett R
Int Orthop; 2013 Dec; 37(12):2337-43. PubMed ID: 23974837
[TBL] [Abstract][Full Text] [Related]
20. The Morscher Press Fit acetabular component: a nine- to 13-year review.
Gwynne-Jones DP; Garneti N; Wainwright C; Matheson JA; King R
J Bone Joint Surg Br; 2009 Jul; 91(7):859-64. PubMed ID: 19567847
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]