These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 18455050)

  • 1. Relationship between lumen diameter and length sterilized in the 125L ozone sterilizer.
    Dufresne S; Leblond H; Chaunet M
    Am J Infect Control; 2008 May; 36(4):291-7. PubMed ID: 18455050
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lumen claims of the STERRAD 100NX sterilizer: testing performance limits when processing equipment containing long, narrow lumens.
    Diab-Elschahawi M; Blacky A; Bachhofner N; Koller W
    Am J Infect Control; 2011 Nov; 39(9):770-4. PubMed ID: 21704426
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid.
    Rutala WA; Gergen MF; Weber DJ
    Am J Infect Control; 1998 Aug; 26(4):393-8. PubMed ID: 9721391
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ozone--the latest advance in sterilization of medical devices.
    Murphy L
    Can Oper Room Nurs J; 2006 Jun; 24(2):28, 30-2, 37-8. PubMed ID: 16869464
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens.
    Alfa MJ; DeGagne P; Olson N; Hizon R
    Am J Infect Control; 1998 Oct; 26(5):469-77. PubMed ID: 9795674
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Challenging the Sterrad 100NX sterilizer with different carrier materials and wrappings under experimental "clean" and "dirty" conditions.
    Diab-Elschahawi M; Blacky A; Bachhofner N; Koller W
    Am J Infect Control; 2010 Dec; 38(10):806-10. PubMed ID: 20869138
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer.
    Rutala WA; Gergen MF; Weber DJ
    Infect Control Hosp Epidemiol; 1999 Jul; 20(7):514-6. PubMed ID: 10432166
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Dependency of a microbiological test of a formaldehyde gas sterilization procedure on the shape of objects to be sterilized].
    Spicher G; Borchers U
    Zentralbl Bakteriol Mikrobiol Hyg B; 1983 Jun; 177(5):419-35. PubMed ID: 6367309
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Elevating the standard of endoscope processing: Terminal sterilization of duodenoscopes using a hydrogen peroxide-ozone sterilizer.
    Molloy-Simard V; Lemyre JL; Martel K; Catalone BJ
    Am J Infect Control; 2019 Mar; 47(3):243-250. PubMed ID: 30442443
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of low-temperature hydrogen peroxide gas plasma sterilization for endoscopes using various Sterrad models.
    Okpara-Hofmann J; Knoll M; Dürr M; Schmitt B; Borneff-Lipp M
    J Hosp Infect; 2005 Apr; 59(4):280-5. PubMed ID: 15749314
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microwave desorption: a combined sterilizer/aerator for the accelerated elimination of ethylene oxide residues from sterilized supplies.
    Samuel AH; Matthews IP; Gibson C
    Med Instrum; 1988 Feb; 22(1):39-44. PubMed ID: 3357464
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of ion plasma, vaporized hydrogen peroxide, and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer.
    Alfa MJ; DeGagne P; Olson N; Puchalski T
    Infect Control Hosp Epidemiol; 1996 Feb; 17(2):92-100. PubMed ID: 8835444
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization of a novel headspace-solid-phase microextraction-gas chromatographic method by means of a Doehlert uniform shell design for the analysis of trace level ethylene oxide residuals in sterilized medical devices.
    DiCicco MP; Lang B; Harper TI
    Biomed Chromatogr; 2009 Jun; 23(6):647-57. PubMed ID: 19277966
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of low-temperature steam with formaldehyde sterilization for endoscopes, using validation device.
    Kanemitsu K; Ogawa A; Hatori T; Imasaka T; Kunishima H; Inden K; Hatta M; Nakamura I; Hirayama Y; Kaku M
    Gastrointest Endosc; 2005 Dec; 62(6):928-32. PubMed ID: 16301039
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Cost comparison of two reprocessing procedures of flexible ureteroscopes at the University Hospital of Dijon].
    Muggeo E; Boissel A; Martin L; Sgro C; Michiels C
    Prog Urol; 2015 May; 25(6):318-24. PubMed ID: 25775971
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safety of plasma-based sterilization: surface modifications of polymeric medical devices induced by Sterrad and Plazlyte processes.
    Lerouge S; Tabrizian M; Wertheimer MR; Marchand R; Yahia L
    Biomed Mater Eng; 2002; 12(1):3-13. PubMed ID: 11847405
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improving the ethylene oxide sterilization process.
    Berth L; Wolffbrandt KH
    Med Device Technol; 1992; 3(5):38-44. PubMed ID: 10171589
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effectiveness of the SYSTEM 1E Liquid Chemical Sterilant Processing System for reprocessing duodenoscopes.
    McDonnell G; Ehrman M; Kiess S
    Am J Infect Control; 2016 Jun; 44(6):685-8. PubMed ID: 26948402
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A sensitive estimation of residual ethylene glycol in ethylene oxide sterilized medical devices by HPLC with electrospray ionization mass spectrometric detection.
    Hari PR; Naseerali CP; Sreenivasan K
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Jan; 877(3):328-32. PubMed ID: 19112050
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ethylene oxide sterilization of medical devices: a review.
    Mendes GC; Brandão TR; Silva CL
    Am J Infect Control; 2007 Nov; 35(9):574-81. PubMed ID: 17980234
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.