BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

620 related articles for article (PubMed ID: 18469652)

  • 21. Safety and efficacy of conversion from external fixation to plate fixation in humeral shaft fractures.
    Suzuki T; Hak DJ; Stahel PF; Morgan SJ; Smith WR
    J Orthop Trauma; 2010 Jul; 24(7):414-9. PubMed ID: 20577071
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Healing the Index Humeral Shaft Nonunion: Risk Factors for Development of a Recalcitrant Nonunion in 125 Patients.
    Wiss DA; Garlich JM
    J Bone Joint Surg Am; 2020 Mar; 102(5):375-380. PubMed ID: 31895240
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Long-term outcome following additional rhBMP-7 application in revision surgery of aseptic humeral, femoral, and tibial shaft nonunion.
    Hackl S; Hierholzer C; Friederichs J; Woltmann A; Bühren V; von Rüden C
    BMC Musculoskelet Disord; 2017 Aug; 18(1):342. PubMed ID: 28784168
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [EFFECTIVENESS OF LOCKING COMPRESS PLATE FOR TREATMENT OF ASEPTIC DIAPHYSEAL HUMERAL NONUNIONS].
    Li J; Yin P; Zhang H; Zhang L; Liang Y; Zhou J; Li C; Cao Yanxiang ; Zhang H; Tang P
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2015 Oct; 29(10):1230-4. PubMed ID: 26749729
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Treatment of humeral shaft nonunion by external fixation: a valuable option.
    Martínez AA ; Herrera A; Pérez JM; Cuenca J; Martínez J
    J Orthop Sci; 2001; 6(3):238-41. PubMed ID: 11484117
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Nonunion of the humeral shaft.
    Healy WL; White GM; Mick CA; Brooker AF; Weiland AJ
    Clin Orthop Relat Res; 1987 Jun; (219):206-13. PubMed ID: 3555925
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Recalcitrant aseptic atrophic non-union of the shaft of the humerus after failure of surgical treatment: management by excision of non-union, bone grafting and stabilization by LCP in different modes.
    Babhulkar S; Babhulkar S; Vasudev A
    Injury; 2017 Aug; 48 Suppl 2():S33-S43. PubMed ID: 28802419
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Single versus double plate fixation of humeral shaft nonunion.
    Unal M; Katı YA; Acar B; Turan A; Ozturk S; Yuksel HY
    Arch Orthop Trauma Surg; 2024 Feb; 144(2):693-699. PubMed ID: 37930359
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Treatment of nonunion of humeral shaft fracture with dynamic compression plate and cancellous bone graft.
    Hsu TL; Chiu FY; Chen CM; Chen TH
    J Chin Med Assoc; 2005 Feb; 68(2):73-6. PubMed ID: 15759818
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [A biomechanical study on internal and external fixation devices for treatment of humeral shaft fracture].
    Niu X; Huang F; Cen S; Qin T; Wang R; Shang Z; Liu A; Zheng H
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 May; 22(5):516-9. PubMed ID: 18630425
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Closing the gap: a novel technique for humeral shaft nonunions using cup and cone reamers.
    Nickel BT; Klement MR; Richard MJ; Zura R; Garrigues GE
    Injury; 2016 Dec; 47 Suppl 7():S40-S43. PubMed ID: 28040077
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Persistent radial palsy after humeral diaphyseal fracture: cause, treatment, and results. 30 operated cases].
    Cognet JM; Fabre T; Durandeau A
    Rev Chir Orthop Reparatrice Appar Mot; 2002 Nov; 88(7):655-62. PubMed ID: 12457110
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Surgical management of humeral shaft nonunions. Success of a consistent protocol over 17 years.
    Zalavras CG; Yasmeh S; Bougioukli S
    Injury; 2021 Dec; 52(12):3580-3587. PubMed ID: 33933273
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Non-union of the humeral shaft treated by internal fixation.
    Kumar A; Sadiq SA
    Int Orthop; 2002; 26(4):214-6. PubMed ID: 12185522
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Two-plate fixation for humeral shaft non-unions.
    Martinez AA; Cuenca J; Herrera A
    J Orthop Surg (Hong Kong); 2009 Aug; 17(2):135-8. PubMed ID: 19721137
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Predictive Factors and Treatment of Aseptic Pseudoarthrosis of the Humeral Shaft].
    Popelka V; Popelka V
    Acta Chir Orthop Traumatol Cech; 2022; 89(5):360-369. PubMed ID: 36322037
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Plate fixation with autogenous bone grafting for longstanding humeral shaft nonunion: A retrospective study of 6 cases.
    Feng D; Zhang J; Zhu Y; Wu S; Shan J; Ye A; Wang Z; Gao T; Wang H; Zhang K
    Medicine (Baltimore); 2018 Aug; 97(35):e11974. PubMed ID: 30170396
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Factors affecting the incidence of aseptic nonunion after surgical fixation of humeral diaphyseal fracture.
    Ding L; He Z; Xiao H; Chai L; Xue F
    J Orthop Sci; 2014 Nov; 19(6):973-7. PubMed ID: 25196794
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Treatment of humeral shaft aseptic nonunions in elderly patients with opposite structural allograft, BMP-7, and mesenchymal stem cells.
    Murena L; Canton G; Vulcano E; Surace MF; Cherubino P
    Orthopedics; 2014 Feb; 37(2):e201-6. PubMed ID: 24679209
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dynamic compression plate and cancellous bone graft for aseptic nonunion after intramedullary nailing of femoral fracture.
    Chen CM; Su YP; Hung SH; Lin CL; Chiu FY
    Orthopedics; 2010 Jun; 33(6):393. PubMed ID: 20806765
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 31.