These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

69 related articles for article (PubMed ID: 18475009)

  • 1. Changes in prescribed doses for the Seattle neutron therapy system.
    Popescu A
    Phys Med Biol; 2008 Jun; 53(11):2985-90. PubMed ID: 18475009
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Dosimetric computer-assisted planning of therapy of malignant tumors with fast neutron beam of cyclotron U-120].
    Lisin VA
    Med Radiol (Mosk); 1991; 36(1):26-8. PubMed ID: 1996050
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The dependency of wedge factors on field size and depth in megavoltage beams.
    Avadhani JS; Pradhan AS; Sankar A; Viswanathan PS
    Strahlenther Onkol; 1996 Nov; 172(11):626-30. PubMed ID: 8946032
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical implementation of enhanced dynamic wedges into the Pinnacle treatment planning system: Monte Carlo validation and patient-specific QA.
    Ahmad M; Deng J; Lund MW; Chen Z; Kimmett J; Moran MS; Nath R
    Phys Med Biol; 2009 Jan; 54(2):447-65. PubMed ID: 19098353
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A semiempirical method for the description of off-center ratios at depth from linear accelerators.
    Tsalafoutas IA; Xenofos S; Yakoumakis E; Nikoletopoulos S
    Med Dosim; 2003; 28(2):119-25. PubMed ID: 12804711
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neutron dose planning with the MEVAPLAN system.
    Schmidt R; Thom E
    Strahlenther Onkol; 1990 Apr; 166(4):301-5. PubMed ID: 2330546
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative study of dose calculations with SERA and JCDS treatment planning systems.
    Koivunoro H; Kumada H; Seppälä T; Kotiluoto P; Auterinen I; Kankaanranta L; Savolainen S
    Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S126-9. PubMed ID: 19406653
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Scattering kernels for fast neutron therapy treatment planning.
    Moffitt GB; Wootton LS; Hårdemark B; Sandison GA; Laramore GE; Parvathaneni U; Stewart RD
    Phys Med Biol; 2020 Aug; 65(16):165009. PubMed ID: 32512540
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurements of the neutron dose near a 15 Mv medical linear accelerator.
    Golnik N; Zielczynski M; Bulski W; Tulik P; Palko T
    Radiat Prot Dosimetry; 2007; 126(1-4):619-22. PubMed ID: 17513292
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sensitivity of different dose scoring methods on organ-specific neutron dose calculations in proton therapy.
    Jarlskog CZ; Paganetti H
    Phys Med Biol; 2008 Sep; 53(17):4523-32. PubMed ID: 18677040
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implementation and experimental validation of the high dose rate stereotactic treatment mode at Varian accelerators.
    Hoffmann L
    Acta Oncol; 2009; 48(2):201-8. PubMed ID: 18759143
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetrical verification of calculated total and gamma absorbed dose distributions DT, respectively DG, for fast neutron therapy.
    Rassow J; Temme A; Baumhoer W; Meissner P
    Strahlentherapie; 1984 Mar; 160(3):168-79. PubMed ID: 6729857
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation between detector array measurements and a computer algorithm for enhanced dynamic wedge profiles.
    Gossman MS; Robertson MA; Lawson RC
    Med Dosim; 2007; 32(3):211-5. PubMed ID: 17707202
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preliminary liver dose estimation in the new facility for biomedical applications at the RA-3 reactor.
    Gadan M; Crawley V; Thorp S; Miller M
    Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S206-9. PubMed ID: 19394239
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Wedge factor dependence with depth, field size, and nominal distance--a general computational rule.
    Popescu A; Lai K; Singer K; Phillips M
    Med Phys; 1999 Apr; 26(4):541-9. PubMed ID: 10227357
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Wedge filter for fast neutron beam from NIRS cyclotron].
    Kutsutani-Nakamura Y; Furukawa S; Iinuma T; Tsunemoto H; Kawashima K; Hoshino K; Hiraoka T; Maruyama T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1983 May; 43(5):691-9. PubMed ID: 6622248
    [No Abstract]   [Full Text] [Related]  

  • 17. Assessment of dose rate scaling factors used in NCTPlan treatment planning code for the BNCT beam of THOR.
    Hsu FY; Liu MT; Tung CJ; Hsueh Liu YW; Chang CC; Liu HM; Chou FI
    Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S130-3. PubMed ID: 19375926
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Secondary neutron doses for several beam configurations for proton therapy.
    Shin D; Yoon M; Kwak J; Shin J; Lee SB; Park SY; Park S; Kim DY; Cho KH
    Int J Radiat Oncol Biol Phys; 2009 May; 74(1):260-5. PubMed ID: 19362245
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wedge factor dependence with depth and field size for fast neutron beams.
    Popescu A; Risler R
    Phys Med Biol; 2003 Jul; 48(14):2123-31. PubMed ID: 12894974
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Verification of the accuracy of BNCT treatment planning system THORplan.
    Li HS; Liu YW; Lee CY; Lin TY; Hsu FY
    Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S122-5. PubMed ID: 19386507
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.