647 related articles for article (PubMed ID: 18485690)
1. AFM nanometer surface morphological study of in situ electropolymerized neutral red redox mediator oxysilane sol-gel encapsulated glucose oxidase electrochemical biosensors.
Chiorcea-Paquim AM; Pauliukaite R; Brett CM; Oliveira-Brett AM
Biosens Bioelectron; 2008 Oct; 24(2):297-305. PubMed ID: 18485690
[TBL] [Abstract][Full Text] [Related]
2. Design and application of a flow cell for carbon-film based electrochemical enzyme biosensors.
Barsan MM; Klincar J; Batic M; Brett CM
Talanta; 2007 Mar; 71(5):1893-900. PubMed ID: 19071539
[TBL] [Abstract][Full Text] [Related]
3. Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode.
Salimi A; Compton RG; Hallaj R
Anal Biochem; 2004 Oct; 333(1):49-56. PubMed ID: 15351279
[TBL] [Abstract][Full Text] [Related]
4. Preparation and characterization of urease-encapsulated biosensors in poly(vinyl alcohol)-modified silica sol-gel materials.
Tsai HC; Doong RA
Biosens Bioelectron; 2007 Aug; 23(1):66-73. PubMed ID: 17475471
[TBL] [Abstract][Full Text] [Related]
5. Co-immobilization of glucose oxidase and hexokinase on silicate hybrid sol-gel membrane for glucose and ATP detections.
Liu S; Sun Y
Biosens Bioelectron; 2007 Jan; 22(6):905-11. PubMed ID: 16687247
[TBL] [Abstract][Full Text] [Related]
6. Immobilization and direct electrochemistry of glucose oxidase on a tetragonal pyramid-shaped porous ZnO nanostructure for a glucose biosensor.
Dai Z; Shao G; Hong J; Bao J; Shen J
Biosens Bioelectron; 2009 Jan; 24(5):1286-91. PubMed ID: 18774704
[TBL] [Abstract][Full Text] [Related]
7. Direct electrochemistry of glucose oxidase in a colloid Au-dihexadecylphosphate composite film and its application to develop a glucose biosensor.
Wu Y; Hu S
Bioelectrochemistry; 2007 May; 70(2):335-41. PubMed ID: 16766233
[TBL] [Abstract][Full Text] [Related]
8. Glucose biosensor based on electrodeposition of platinum nanoparticles onto carbon nanotubes and immobilizing enzyme with chitosan-SiO(2) sol-gel.
Zou Y; Xiang C; Sun LX; Xu F
Biosens Bioelectron; 2008 Feb; 23(7):1010-6. PubMed ID: 18054479
[TBL] [Abstract][Full Text] [Related]
9. One-step immobilization of glucose oxidase in a silica matrix on a Pt electrode by an electrochemically induced sol-gel process.
Jia WZ; Wang K; Zhu ZJ; Song HT; Xia XH
Langmuir; 2007 Nov; 23(23):11896-900. PubMed ID: 17929847
[TBL] [Abstract][Full Text] [Related]
10. A simple method to fabricate a chitosan-gold nanoparticles film and its application in glucose biosensor.
Du Y; Luo XL; Xu JJ; Chen HY
Bioelectrochemistry; 2007 May; 70(2):342-7. PubMed ID: 16793348
[TBL] [Abstract][Full Text] [Related]
11. Polyazetidine-based immobilization of redox proteins for electron-transfer-based biosensors.
Frasconi M; Favero G; Di Fusco M; Mazzei F
Biosens Bioelectron; 2009 Jan; 24(5):1424-30. PubMed ID: 18829298
[TBL] [Abstract][Full Text] [Related]
12. Improved selectivity and stability of glucose biosensor based on in situ electropolymerized polyaniline-polyacrylonitrile composite film.
Xue H; Shen Z; Li C
Biosens Bioelectron; 2005 May; 20(11):2330-4. PubMed ID: 15797335
[TBL] [Abstract][Full Text] [Related]
13. Electropolymerization of preoxidized catecholamines on Prussian blue matrix to immobilize glucose oxidase for sensitive amperometric biosensing.
Chen C; Fu Y; Xiang C; Xie Q; Zhang Q; Su Y; Wang L; Yao S
Biosens Bioelectron; 2009 Apr; 24(8):2726-9. PubMed ID: 19167205
[TBL] [Abstract][Full Text] [Related]
14. Application of integrated SECM ultra-micro-electrode and AFM force probe to biosensor surfaces.
Hirata Y; Yabuki S; Mizutani F
Bioelectrochemistry; 2004 Jun; 63(1-2):217-24. PubMed ID: 15110275
[TBL] [Abstract][Full Text] [Related]
15. Multilayered construction of glucose oxidase and silica nanoparticles on Au electrodes based on layer-by-layer covalent attachment.
Sun Y; Yan F; Yang W; Sun C
Biomaterials; 2006 Jul; 27(21):4042-9. PubMed ID: 16566998
[TBL] [Abstract][Full Text] [Related]
16. Nitric oxide-releasing sol-gel particle/polyurethane glucose biosensors.
Shin JH; Marxer SM; Schoenfisch MH
Anal Chem; 2004 Aug; 76(15):4543-9. PubMed ID: 15283600
[TBL] [Abstract][Full Text] [Related]
17. Structure and biosensor characteristics of complex between glucose oxidase and plasma-polymerized nanothin film.
Muguruma H; Kase Y
Biosens Bioelectron; 2006 Dec; 22(5):737-43. PubMed ID: 16600587
[TBL] [Abstract][Full Text] [Related]
18. Gold nanoparticles-induced enhancement of the analytical response of an electrochemical biosensor based on an organic-inorganic hybrid composite material.
Barbadillo M; Casero E; Petit-Domínguez MD; Vázquez L; Pariente F; Lorenzo E
Talanta; 2009 Dec; 80(2):797-802. PubMed ID: 19836554
[TBL] [Abstract][Full Text] [Related]
19. Nanocrystalline diamond modified gold electrode for glucose biosensing.
Zhao W; Xu JJ; Qiu QQ; Chen HY
Biosens Bioelectron; 2006 Dec; 22(5):649-55. PubMed ID: 16563728
[TBL] [Abstract][Full Text] [Related]
20. Sonochemically fabricated microelectrode arrays for biosensors--part II. Modification with a polysiloxane coating.
Myler S; Davis F; Collyer SD; Higson SP
Biosens Bioelectron; 2004 Sep; 20(2):408-12. PubMed ID: 15308248
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]