BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 18490813)

  • 41. [Microwave thermoacoustic signal analysis of biological tissues based on the coupling of multifield].
    Tao C; Song T; Liu G; Yan J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):44-8. PubMed ID: 18435254
    [TBL] [Abstract][Full Text] [Related]  

  • 42. SAR characteristics of the Sigma-60-Ellipse applicator.
    Fatehi D; van Rhoon GC
    Int J Hyperthermia; 2008 Jun; 24(4):347-56. PubMed ID: 18465419
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers.
    Bazán I; Vazquez M; Ramos A; Vera A; Leija L
    Ultrasonics; 2009 Mar; 49(3):358-76. PubMed ID: 19100591
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Spatial averaging of fields from half-wave dipole antennas and corresponding SAR calculations in the NORMAN human voxel model between 65 MHz and 2 GHz.
    Findlay RP; Dimbylow PJ
    Phys Med Biol; 2009 Apr; 54(8):2437-47. PubMed ID: 19336844
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Hyperthermia induced by microwave diathermy in the management of muscle and tendon injuries.
    Giombini A; Giovannini V; Di Cesare A; Pacetti P; Ichinoseki-Sekine N; Shiraishi M; Naito H; Maffulli N
    Br Med Bull; 2007; 83():379-96. PubMed ID: 17942453
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Effects of dielectric parameters of human body on radiation characteristics of ingestible wireless device at operating frequency of 430 MHz.
    Xu L; Meng MQ; Chan Y
    IEEE Trans Biomed Eng; 2009 Aug; 56(8):2083-94. PubMed ID: 19605308
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Experimental measurements and Monte Carlo simulations for dosimetric evaluations of intrafraction motion for gated and ungated intensity modulated arc therapy deliveries.
    Oliver M; Gladwish A; Staruch R; Craig J; Gaede S; Chen J; Wong E
    Phys Med Biol; 2008 Nov; 53(22):6419-36. PubMed ID: 18941277
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The generation of simple compliance boundaries for mobile communication base station antennas using formulae for SAR estimation.
    Thors B; Hansson B; Törnevik C
    Phys Med Biol; 2009 Jul; 54(13):4243-56. PubMed ID: 19531847
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Feasibility of using ultrasound contrast agents to increase the size of thermal lesions induced by non-focused transducers: in vitro demonstration in tissue mimicking phantom.
    Lafon C; Murillo-Rincon A; Goldenstedt C; Chapelon JY; Mithieux F; Owen NR; Cathignol D
    Ultrasonics; 2009 Feb; 49(2):172-8. PubMed ID: 18796342
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Determinants of lesion dimensions during transcatheter microwave ablation.
    Tse HF; Liao S; Siu CW; Yuan L; Nicholls J; Leung G; Ormsby T; Feld GK; Lau CP
    Pacing Clin Electrophysiol; 2009 Feb; 32(2):201-8. PubMed ID: 19170909
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Density and spatial resolutions of proton radiography using a range modulation technique.
    Ryu H; Song E; Lee J; Kim J
    Phys Med Biol; 2008 Oct; 53(19):5461-8. PubMed ID: 18765893
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Monte Carlo simulation of the response of ESR dosimeters added with gadolinium exposed to thermal, epithermal and fast neutrons.
    Marrale M; Basile S; Brai M; Longo A
    Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S186-9. PubMed ID: 19380235
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [Biophysical features of microwave therapy].
    Volobuev AN
    Vopr Kurortol Fizioter Lech Fiz Kult; 2007; (2):26-9. PubMed ID: 17563983
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Microwave Transmittance Technique Using Microstrip Patch Antennas, as a Non-Invasive Tool to Determine Soil Moisture in Rhizoboxes.
    Herrmann PSP; Sydoruk V; Marques Porto FN
    Sensors (Basel); 2020 Feb; 20(4):. PubMed ID: 32093329
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Microwave bone imaging: a preliminary scanning system for proof-of-concept.
    Ruvio G; Cuccaro A; Solimene R; Brancaccio A; Basile B; Ammann MJ
    Healthc Technol Lett; 2016 Sep; 3(3):218-221. PubMed ID: 27733930
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Dielectric properties of muscle and adipose tissue-mimicking solutions for microwave medical imaging applications.
    Pollacco DA; Conti MC; Farrugia L; Wismayer PS; Farina L; Sammut CV
    Phys Med Biol; 2019 Apr; 64(9):095009. PubMed ID: 30844769
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Monte Carlo modelling of the treatment line of the Proton Therapy Center in Orsay.
    Stankovskiy A; Kerhoas-Cavata S; Ferrand R; Nauraye C; Demarzi L
    Phys Med Biol; 2009 Apr; 54(8):2377-94. PubMed ID: 19321923
    [TBL] [Abstract][Full Text] [Related]  

  • 58. 3-D-microwave breast tumor detection: study of system performance.
    de Lorenzo Rodríguez ME; Vera-Isasa M; Santalla del Río V
    IEEE Trans Biomed Eng; 2008 Dec; 55(12):2772-7. PubMed ID: 19126457
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Image registration of a moving target phantom with helical tomotherapy: effect of the CT acquisition technique and action level proposal.
    Woodford C; Yartsev S; Van Dyk J
    Phys Med Biol; 2008 Sep; 53(18):5093-106. PubMed ID: 18723925
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Implementation of a phase array diffuse optical tomographic imager.
    Rajan K; Vijayakumar V; Biswas SK; Vasu RM
    Rev Sci Instrum; 2008 Aug; 79(8):084301. PubMed ID: 19044366
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.