These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
389 related articles for article (PubMed ID: 18491697)
1. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head. Scholes SC; Inman IA; Unsworth A; Jones E Proc Inst Mech Eng H; 2008 Apr; 222(3):273-83. PubMed ID: 18491697 [TBL] [Abstract][Full Text] [Related]
2. Pitch-based carbon-fibre-reinforced poly (ether-ether-ketone) OPTIMA assessed as a bearing material in a mobile bearing unicondylar knee joint. Scholes SC; Unsworth A Proc Inst Mech Eng H; 2009 Jan; 223(1):13-25. PubMed ID: 19239064 [TBL] [Abstract][Full Text] [Related]
3. Wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted carbon fiber reinforced poly(ether ether ketone) liners against metal and ceramic femoral heads. Yamane S; Kyomoto M; Moro T; Hashimoto M; Takatori Y; Tanaka S; Ishihara K J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):1028-1037. PubMed ID: 28485068 [TBL] [Abstract][Full Text] [Related]
4. Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating. Wang QQ; Wu JJ; Unsworth A; Briscoe A; Jarman-Smith M; Lowry C; Simpson D; Collins S J Mater Sci Mater Med; 2012 Jun; 23(6):1533-42. PubMed ID: 22454139 [TBL] [Abstract][Full Text] [Related]
5. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation. Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782 [TBL] [Abstract][Full Text] [Related]
6. Wear of ceramic-on-carbon fiber-reinforced poly-ether ether ketone hip replacements. Brockett CL; John G; Williams S; Jin Z; Isaac GH; Fisher J J Biomed Mater Res B Appl Biomater; 2012 Aug; 100(6):1459-65. PubMed ID: 22454322 [TBL] [Abstract][Full Text] [Related]
7. Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads. Galvin A; Brockett C; Williams S; Hatto P; Burton A; Isaac G; Stone M; Ingham E; Fisher J Proc Inst Mech Eng H; 2008 Oct; 222(7):1073-80. PubMed ID: 19024155 [TBL] [Abstract][Full Text] [Related]
8. The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine. Scholes SC; Unsworth A Proc Inst Mech Eng H; 2007 Apr; 221(3):281-9. PubMed ID: 17539583 [TBL] [Abstract][Full Text] [Related]
9. Technical and histologic analysis of a retrieved carbon fiber-reinforced poly-ether-ether-ketone composite alumina-bearing liner 28 months after implantation. Pace N; Marinelli M; Spurio S J Arthroplasty; 2008 Jan; 23(1):151-5. PubMed ID: 18165046 [TBL] [Abstract][Full Text] [Related]
10. Wear behaviour of CFR PEEK articulated against CoCr under varying contact stresses: Low wear of CFR PEEK negated by wear of the CoCr counterface. Kandemir G; Smith S; Joyce TJ J Mech Behav Biomed Mater; 2019 Sep; 97():117-125. PubMed ID: 31108368 [TBL] [Abstract][Full Text] [Related]
11. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Goldsmith AA; Dowson D; Isaac GH; Lancaster JG Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049 [TBL] [Abstract][Full Text] [Related]
12. Wear of polyethylene in artificial hip joints: superolateral wear of the acetabulum. Fisher J J Bone Joint Surg Br; 1998 Mar; 80(2):190-1. PubMed ID: 9546441 [No Abstract] [Full Text] [Related]
13. Biotribology of a new bearing material combination in a rotating hinge knee articulation. Grupp TM; Giurea A; Miehlke RK; Hintner M; Gaisser M; Schilling C; Schwiesau J; Kaddick C Acta Biomater; 2013 Jun; 9(6):7054-63. PubMed ID: 23485855 [TBL] [Abstract][Full Text] [Related]
14. The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester. Baykal D; Siskey RS; Underwood RJ; Briscoe A; Kurtz SM Clin Orthop Relat Res; 2016 Nov; 474(11):2384-2393. PubMed ID: 27457625 [TBL] [Abstract][Full Text] [Related]
15. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator. Smith SL; Unsworth A Proc Inst Mech Eng H; 1999; 213(6):475-83. PubMed ID: 10635696 [TBL] [Abstract][Full Text] [Related]
16. Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint. Scholes SC; Burgess IC; Marsden HR; Unsworth A; Jones E; Smith N Proc Inst Mech Eng H; 2006 Jul; 220(5):583-96. PubMed ID: 16898216 [TBL] [Abstract][Full Text] [Related]
17. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055 [TBL] [Abstract][Full Text] [Related]
18. Wear properties of alumina/zirconia composite ceramics for joint prostheses measured with an end-face apparatus. Morita Y; Nakata K; Kim YH; Sekino T; Niihara K; Ikeuchi K Biomed Mater Eng; 2004; 14(3):263-70. PubMed ID: 15299238 [TBL] [Abstract][Full Text] [Related]
19. Tribological and surface analysis of 38 mm alumina-as-cast Co-Cr-Mo total hip arthroplasties. Williams SR; Wu JJ; Unsworth A; Khan I Proc Inst Mech Eng H; 2009 Nov; 223(8):941-54. PubMed ID: 20092092 [TBL] [Abstract][Full Text] [Related]
20. Understanding the differences between the wear of metal-on-metal and ceramic-on-metal total hip replacements. Figueiredo-Pina CG; Yan Y; Neville A; Fisher J Proc Inst Mech Eng H; 2008 Apr; 222(3):285-96. PubMed ID: 18491698 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]