These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 18495978)

  • 61. Introduction of audio gating to further reduce organ motion in breathing synchronized radiotherapy.
    Kubo HD; Wang L
    Med Phys; 2002 Mar; 29(3):345-50. PubMed ID: 11929017
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Respiratory monitoring with an acceleration sensor.
    Ono T; Takegawa H; Ageishi T; Takashina M; Numasaki H; Matsumoto M; Teshima T
    Phys Med Biol; 2011 Oct; 56(19):6279-89. PubMed ID: 21896964
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Optimization of fluoroscopy parameters using pattern matching prediction in the real-time tumor-tracking radiotherapy system.
    Miyamoto N; Ishikawa M; Bengua G; Sutherland K; Suzuki R; Kimura S; Shimizu S; Onimaru R; Shirato H
    Phys Med Biol; 2011 Aug; 56(15):4803-13. PubMed ID: 21753230
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Respiratory gating with EPID-based verification: the MDACC experience.
    Briere TM; Beddar S; Balter P; Murthy R; Gupta S; Nelson C; Starkschall G; Gillin MT; Krishnan S
    Phys Med Biol; 2009 Jun; 54(11):3379-91. PubMed ID: 19436104
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Residual motion and duty time in respiratory gating radiotherapy using individualized or population-based windows.
    Fuji H; Asada Y; Numano M; Yamashita H; Nishimura T; Hashimoto T; Harada H; Asakura H; Murayama S
    Int J Radiat Oncol Biol Phys; 2009 Oct; 75(2):564-70. PubMed ID: 19735882
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Real-time 4-D radiotherapy for lung cancer.
    Shirato H; Onimaru R; Ishikawa M; Kaneko J; Takeshima T; Mochizuki K; Shimizu S; Umegaki K
    Cancer Sci; 2012 Jan; 103(1):1-6. PubMed ID: 21954991
    [TBL] [Abstract][Full Text] [Related]  

  • 67. The feasibility of the auto tuning respiratory compensation system with ultrasonic image tracking technique.
    Chuang HC; Hsu HY; Nieh SK; Tien DC
    J Xray Sci Technol; 2015; 23(4):503-16. PubMed ID: 26410661
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Verification and compensation of respiratory motion using an ultrasound imaging system.
    Chuang HC; Hsu HY; Chiu WH; Tien DC; Wu RH; Hsu CH
    Med Phys; 2015 Mar; 42(3):1193-9. PubMed ID: 25735274
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Issues in respiratory motion compensation during external-beam radiotherapy.
    Ozhasoglu C; Murphy MJ
    Int J Radiat Oncol Biol Phys; 2002 Apr; 52(5):1389-99. PubMed ID: 11955754
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Effect of audio coaching on correlation of abdominal displacement with lung tumor motion.
    Nakamura M; Narita Y; Matsuo Y; Narabayashi M; Nakata M; Sawada A; Mizowaki T; Nagata Y; Hiraoka M
    Int J Radiat Oncol Biol Phys; 2009 Oct; 75(2):558-63. PubMed ID: 19735881
    [TBL] [Abstract][Full Text] [Related]  

  • 71. A CT-guided robotic needle puncture method for lung tumours with respiratory motion.
    Wei L; Jiang S; Yang Z; Zhang G; Ma L
    Phys Med; 2020 May; 73():48-56. PubMed ID: 32315807
    [TBL] [Abstract][Full Text] [Related]  

  • 72. The diaphragm as an anatomic surrogate for lung tumor motion.
    Cerviño LI; Chao AK; Sandhu A; Jiang SB
    Phys Med Biol; 2009 Jun; 54(11):3529-41. PubMed ID: 19443952
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Development of a novel radiotherapy motion phantom using a stepper motor driver circuit and evaluation using optical surface scanning.
    Lempart M; Kügele M; Snäll J; Ambolt L; Ceberg S
    Australas Phys Eng Sci Med; 2017 Sep; 40(3):717-727. PubMed ID: 28523468
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Respiration gated radiotherapy treatment: a technical study.
    Kubo HD; Hill BC
    Phys Med Biol; 1996 Jan; 41(1):83-91. PubMed ID: 8685260
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center.
    Kubo HD; Len PM; Minohara S; Mostafavi H
    Med Phys; 2000 Feb; 27(2):346-53. PubMed ID: 10718138
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Adaptive confidence regions for indirect tracking of moving tumors in radiotherapy.
    Remy C; Bouchard H
    Med Phys; 2022 Jul; 49(7):4273-4283. PubMed ID: 35502559
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Tumor motion prediction with the diaphragm as a surrogate: a feasibility study.
    Cerviño LI; Jiang Y; Sandhu A; Jiang SB
    Phys Med Biol; 2010 May; 55(9):N221-9. PubMed ID: 20371906
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Motion management in particle therapy.
    Mori S; Knopf AC; Umegaki K
    Med Phys; 2018 Nov; 45(11):e994-e1010. PubMed ID: 30421815
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Unsupervised Learning for Robust Respiratory Signal Estimation From X-Ray Fluoroscopy.
    Fischer P; Pohl T; Faranesh A; Maier A; Hornegger J
    IEEE Trans Med Imaging; 2017 Apr; 36(4):865-877. PubMed ID: 27654320
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Irradiation synchronized with respiration gate.
    Ohara K; Okumura T; Akisada M; Inada T; Mori T; Yokota H; Calaguas MJ
    Int J Radiat Oncol Biol Phys; 1989 Oct; 17(4):853-7. PubMed ID: 2777676
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.