BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

285 related articles for article (PubMed ID: 18496274)

  • 1. Continuous flow total artificial heart: modeling and feedback control in a mock circulatory system.
    Khalil HA; Kerr DT; Franchek MA; Metcalfe RW; Benkowski RJ; Cohn WE; Tuzun E; Radovancevic B; Frazier OH; Kadipasaoglu KA
    ASAIO J; 2008; 54(3):249-55. PubMed ID: 18496274
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Induced pulsation of a continuous-flow total artificial heart in a mock circulatory system.
    Khalil HA; Kerr DT; Schusterman MA; Cohn WE; Frazier OH; Radovancevic B
    J Heart Lung Transplant; 2010 May; 29(5):568-73. PubMed ID: 20153967
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of a reliable automatic speed control system for rotary blood pumps.
    Vollkron M; Schima H; Huber L; Benkowski R; Morello G; Wieselthaler G
    J Heart Lung Transplant; 2005 Nov; 24(11):1878-85. PubMed ID: 16297795
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Investigation of the inherent left-right flow balancing of rotary total artificial hearts by means of a resistance box.
    Nestler F; Timms DL; Stevens M; Bradley AP; Wilson SJ; Kleinheyer M; Lovell N; Frazier OH; Cohn WE
    Artif Organs; 2020 Jun; 44(6):584-593. PubMed ID: 31912510
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.
    Glynn J; Song H; Hull B; Withers S; Gelow J; Mudd J; Starr A; Wampler R
    Artif Organs; 2017 Oct; 41(10):904-910. PubMed ID: 28703280
    [TBL] [Abstract][Full Text] [Related]  

  • 6. First clinical experience with an automatic control system for rotary blood pumps during ergometry and right-heart catheterization.
    Schima H; Vollkron M; Jantsch U; Crevenna R; Roethy W; Benkowski R; Morello G; Quittan M; Hiesmayr M; Wieselthaler G
    J Heart Lung Transplant; 2006 Feb; 25(2):167-73. PubMed ID: 16446216
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An artificial right ventricle for failing fontan: in vitro and computational study.
    Lacour-Gayet FG; Lanning CJ; Stoica S; Wang R; Rech BA; Goldberg S; Shandas R
    Ann Thorac Surg; 2009 Jul; 88(1):170-6. PubMed ID: 19559219
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automatic control of the artificial heart.
    Pierce WS; Landis D; O'Bannon W; Donachy JH; White W; Phillips W; Brighton JA
    Trans Am Soc Artif Intern Organs; 1976; 22():347-56. PubMed ID: 951850
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A control system for rotary blood pumps based on suction detection.
    Ferreira A; Boston JR; Antaki JF
    IEEE Trans Biomed Eng; 2009 Mar; 56(3):656-65. PubMed ID: 19272919
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimization of axial-pump pressure sensitivity for a continuous-flow total artificial heart.
    Frazier OH; Khalil HA; Benkowski RJ; Cohn WE
    J Heart Lung Transplant; 2010 Jun; 29(6):687-91. PubMed ID: 20133164
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: a feasibility study.
    Frazier OH; Tuzun E; Cohn WE; Conger JL; Kadipasaoglu KA
    ASAIO J; 2006; 52(2):145-9. PubMed ID: 16557099
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mock circulation loop to investigate hemolysis in a pulsatile total artificial heart.
    Gräf F; Finocchiaro T; Laumen M; Mager I; Steinseifer U
    Artif Organs; 2015 May; 39(5):416-22. PubMed ID: 25586541
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of the functionally total artificial heart using an artery pump.
    Li GR; Zhu XD
    ASAIO J; 2007; 53(3):288-91. PubMed ID: 17515716
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulated Performance of the Cleveland Clinic Continuous-Flow Total Artificial Heart Using the Virtual Mock Loop.
    Miyamoto T; Horvath DJ; Horvath DW; Karimov JH; Byram N; Kuban BD; Fukamachi K
    ASAIO J; 2019 Aug; 65(6):565-572. PubMed ID: 30074965
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Can total artificial heart animals control their TAH by themselves? One year survival of a TAH goat using a new automatic control method (1/R control).
    Abe Y; Chinzei T; Imachi K; Mabuchi K; Imanishi K; Isoyama T; Matsuura H; Senih G; Nozawa H; Kouno A
    ASAIO J; 1994; 40(3):M506-9. PubMed ID: 8555567
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Construction of an artificial heart pump performance test system.
    Liu Y; Allaire P; Wu Y; Wood H; Olsen D
    Cardiovasc Eng; 2006 Dec; 6(4):151-8. PubMed ID: 17136597
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A bridge from short-term to long-term left ventricular assist device--experimental verification of a physiological controller.
    Wu Y; Allaire PE; Tao G; Adams M; Liu Y; Wood H; Olsen DB
    Artif Organs; 2004 Oct; 28(10):927-32. PubMed ID: 15385000
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices.
    Timms D; Hayne M; McNeil K; Galbraith A
    Artif Organs; 2005 Jul; 29(7):564-72. PubMed ID: 15982285
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing.
    Liu Y; Allaire P; Wood H; Olsen D
    Artif Organs; 2005 Apr; 29(4):341-5. PubMed ID: 15787631
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pressures generated within the chambers of the MagScrew TAH: an in vitro study.
    Flick CR; Weber S; Luangphakdy V; Klatte RS; Fukamachi K; Smith WA
    ASAIO J; 2008; 54(1):58-63. PubMed ID: 18204317
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.