These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

285 related articles for article (PubMed ID: 18496274)

  • 21. Acute in vivo evaluation of an implantable continuous flow biventricular assist system.
    Saeed D; Ootaki Y; Ootaki C; Akiyama M; Horai T; Catanese J; Fumoto H; Dessoffy R; Massiello AL; Horvath DJ; Zhou Q; Chen JF; Benefit S; Golding LA; Fukamachi K
    ASAIO J; 2008; 54(1):20-4. PubMed ID: 18204311
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Preload sensitivity of the Jarvik 2000 and HeartMate II left ventricular assist devices.
    Khalil HA; Cohn WE; Metcalfe RW; Frazier OH
    ASAIO J; 2008; 54(3):245-8. PubMed ID: 18496273
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Minimal sensor count approach to fuzzy logic rotary blood pump flow control.
    Casas F; Ahmed N; Reeves A
    ASAIO J; 2007; 53(2):140-6. PubMed ID: 17413551
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A compact and noise free electrohydraulic total artificial heart.
    Yu LS; Finnegan M; Vaughan S; Ochs B; Parnis S; Frazier OH; Kung RT
    ASAIO J; 1993; 39(3):M386-91. PubMed ID: 8268564
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Analysis of Cleveland Clinic continuous-flow total artificial heart performance using the Virtual Mock Loop: Comparison with an in vivo study.
    Miyamoto T; Horvath DJ; Horvath DW; Kuban BD; Fukamachi K; Karimov JH
    Artif Organs; 2020 Apr; 44(4):375-383. PubMed ID: 31573677
    [TBL] [Abstract][Full Text] [Related]  

  • 26. One month survival with the undulation pump total artificial heart in a goat.
    Abe Y; Chinzei T; Isoyama T; Ono T; Mochizuki S; Saito I; Iwasaki K; Ishimaru M; Karita T; Kuono A; Baba K; Imachi K
    Artif Organs; 2001 Jan; 25(1):69-71. PubMed ID: 11167565
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Fuzzy logic automatic control of the Phoenix-7 total artificial heart.
    Hsu CH
    J Artif Organs; 2004; 7(2):69-76. PubMed ID: 15309673
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A Starling-like total work controller for rotary blood pumps: An in vitro evaluation.
    Wu EL; Stevens MC; Nestler F; Pauls JP; Bradley AP; Tansley G; Fraser JF; Gregory SD
    Artif Organs; 2020 Mar; 44(3):E40-E53. PubMed ID: 31520408
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Rapid Speed Modulation of a Rotary Total Artificial Heart Impeller.
    Kleinheyer M; Timms DL; Tansley GD; Nestler F; Greatrex NA; Frazier OH; Cohn WE
    Artif Organs; 2016 Sep; 40(9):824-33. PubMed ID: 27645393
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Resonant frequency control method for total artificial heart: in vitro study.
    Kosaka R; Sankai Y; Yamane T; Tsutsui T
    Artif Organs; 2008 Feb; 32(2):157-60. PubMed ID: 18269353
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A novel impeller TAH using magnetic bearings for load reduction.
    Qian KX; Ru WM; Zeng P; Yuan HY
    J Med Eng Technol; 2002; 26(5):214-6. PubMed ID: 12487713
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A new method of providing pulsatile flow in a centrifugal pump: assessment of pulsatility using a mock circulatory system.
    Herreros J; Berjano EJ; Sales-Nebot L; Más P; Calvo I; Mastrobuoni S; Mercé S
    Artif Organs; 2008 Jun; 32(6):490-4. PubMed ID: 18422794
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Flow visualization techniques in a mock ventricle supported by a nonpulsatile left ventricular assist device.
    Khalil HA; Metcalfe RW; Kleis SJ; Lee EL; Gilbert NL; Kerr DT; Frazier OH; Cohn WE
    ASAIO J; 2009; 55(4):323-7. PubMed ID: 19512887
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vivo performance evaluation of a transcutaneous energy and information transmission system for the total artificial heart.
    Ahn JM; Kang DW; Kim HC; Min BG
    ASAIO J; 1993; 39(3):M208-12. PubMed ID: 8268530
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Hemodynamic characterization of the Realheart® total artificial heart with a hybrid cardiovascular simulator.
    Fresiello L; Najar A; Brynedal Ignell N; Zieliński K; Rocchi M; Meyns B; Perkins IL
    Artif Organs; 2022 Aug; 46(8):1585-1596. PubMed ID: 35231138
    [TBL] [Abstract][Full Text] [Related]  

  • 36. In vitro and in vivo evaluation of a left-right balancing capacity of an interatrial shunt in an electrohydraulic total artificial heart system.
    Tatsumi E; Nakamura M; Masuzawa T; Taenaka Y; Sohn YS; Nishimura T; Nakata M; Nakatani T; Ohno T; Endo S; Takiura K; Takewa Y; Kakuta Y; Takano H
    ASAIO J; 1997; 43(5):M619-25. PubMed ID: 9360119
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A hybrid mock circulation loop for a total artificial heart.
    Nestler F; Bradley AP; Wilson SJ; Timms DL; Frazier OH; Cohn WE
    Artif Organs; 2014 Sep; 38(9):775-82. PubMed ID: 25234760
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Adaptive physiological speed/flow control of rotary blood pumps in permanent implantation using intrinsic pump parameters.
    Wu Y
    ASAIO J; 2009; 55(4):335-9. PubMed ID: 19506462
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A mock circulatory loop for designing and evaluating total artificial hearts.
    Love HC; Timms DL; Nestler F; Frazier OH; Cohn WE
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():5667-70. PubMed ID: 25571281
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Simulation of a regulation mechanism in inserting an artificial heart, by which the left and right pumps require the same output volume].
    Hecht J; Körner E
    Z Exp Chir Transplant Kunstliche Organe; 1987; 20(2):88-93. PubMed ID: 3604360
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 15.