These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 18498327)

  • 1. Penile prosthesis pump tubing erosion into urethra appearing as inability to catheterize: a case report.
    Brown ET; Saunders SE; Zaslau S
    J Sex Med; 2008 Dec; 5(12):2960-2. PubMed ID: 18498327
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bulbar urethrocavernous fistula in setting of inflatable penile prosthesis: a case report.
    Botkin H; Barnes B; Pearlman A
    BMC Urol; 2021 Feb; 21(1):25. PubMed ID: 33581719
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Late complications of spontaneous urethral erosion of a malleable penile prosthesis in a young patient.
    Ciftci H; Verit A; Savas M
    Singapore Med J; 2012 Jun; 53(6):e120-1. PubMed ID: 22711048
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Erosion of inflatable penile prosthesis reservoir into neobladder.
    Tran CN; Boncher N; Montague DK; Angermeier KW
    J Sex Med; 2013 Sep; 10(9):2343-6. PubMed ID: 23889925
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Severe vascular complication after implantation of a three-piece inflatable penile prosthesis.
    Deho' F; Henry GD; Marone EM; Sacca' A; Chiesa R; Rigatti P; Montorsi F
    J Sex Med; 2008 Dec; 5(12):2956-9. PubMed ID: 19090947
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Isolated pump erosion of an inflatable penile prosthesis through the scrotum in a diabetic patient.
    Talib RA; Shamsodini A; Salem EA; Canguven O; Al Ansari A
    Arch Ital Urol Androl; 2013 Apr; 85(1):53-5. PubMed ID: 23695409
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tips and tricks of inflatable penile prosthesis reservoir placement: a case presentation and discussion.
    Simon R; Hakky TS; Henry G; Perito P; Martinez D; Parker J; Carrion RE
    J Sex Med; 2014 May; 11(5):1325-33. PubMed ID: 24580751
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Erosion of urethra by malleable penile prosthesis in a spinal cord injury patient with diabetes mellitus and repeated misplacement of Foley balloon in the urethra: lessons we learn: a case report.
    Vaidyanathan S; Soni B; Khadr R; Hughes P
    Spinal Cord Ser Cases; 2022 Jan; 8(1):12. PubMed ID: 35064099
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Management of erosion of inflatable penile prosthesis reservoir into bladder. A different approach.
    Izol V; Deger M; Kizilgok B; Aridogan IA; Tansug MZ
    Arch Ital Urol Androl; 2019 Mar; 91(1):43-45. PubMed ID: 30932428
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term infection outcomes after original antibiotic impregnated inflatable penile prosthesis implants: up to 7.7 years of followup.
    Carson CC; Mulcahy JJ; Harsch MR
    J Urol; 2011 Feb; 185(2):614-8. PubMed ID: 21168870
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Combined inflatable penile prosthesis-artificial urinary sphincter implantation: no increased risk of adverse events compared to single or staged device implantation.
    Segal RL; Cabrini MR; Harris ED; Mostwin JL; Bivalacqua TJ; Burnett AL
    J Urol; 2013 Dec; 190(6):2183-8. PubMed ID: 23831315
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rare complication of multiple revision surgeries of penile prosthesis.
    Park JK; Jang SW; Lee SW; Cui Y
    J Sex Med; 2005 Sep; 2(5):735-6. PubMed ID: 16422833
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Malleable Implant Salvage Technique: Infection Outcomes after Mulcahy Salvage Procedure and Replacement of Infected Inflatable Penile Prosthesis with Malleable Prosthesis.
    Gross MS; Phillips EA; Balen A; Eid JF; Yang C; Simon R; Martinez D; Carrion R; Perito P; Levine L; Greenfield J; Munarriz R
    J Urol; 2016 Mar; 195(3):694-7. PubMed ID: 26343986
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Erectile function significant enough for penetration during sexual intercourse after removal of inflatable penile prosthesis.
    Martinez DR; Mennie PA; Carrion R
    J Sex Med; 2012 Nov; 9(11):2938-42. PubMed ID: 22905876
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Revision of penile prosthesis surgery after use of penile traction therapy to increase erect penile length: case report and review of the literature.
    Moskovic DJ; Pastuszak AW; Lipshultz LI; Khera M
    J Sex Med; 2011 Feb; 8(2):607-11. PubMed ID: 21091884
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Management of Perforation Injuries During and Following Penile Prosthesis Surgery.
    Stember DS; Kohler TS; Morey AF
    J Sex Med; 2015 Nov; 12 Suppl 7():456-61. PubMed ID: 26565577
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intravesical penile implant reservoir: case report, literature review, and strategies for prevention.
    Garber BB; Morris A
    Int J Impot Res; 2013; 25(2):41-4. PubMed ID: 22931762
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term delayed extrusion of a penile prosthesis.
    Gacci M; Vittori G; Giubilei G; Nelli F; Rossetti MA; Serni S; Lapini A; Carini M; Natali A
    Arch Ital Urol Androl; 2007 Mar; 79(1):41-2. PubMed ID: 17484406
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Malleable implant substitution for the management of penile prosthesis pump erosion: a pilot study.
    Köhler TS; Modder JK; Dupree JM; Bush NC; McVary KT
    J Sex Med; 2009 May; 6(5):1474-8. PubMed ID: 19453933
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A simple technique for removal of eroded penile prostheses.
    Oesterling JE
    J Urol; 1989 Dec; 142(6):1538-9. PubMed ID: 2585634
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.