These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

244 related articles for article (PubMed ID: 18500596)

  • 1. Using a laryngeal tube during cardiac arrest reduces "no flow time" in a manikin study: a comparison between laryngeal tube and endotracheal tube.
    Wiese CH; Bartels U; Bergmann A; Bergmann I; Bahr J; Graf BM
    Wien Klin Wochenschr; 2008; 120(7-8):217-23. PubMed ID: 18500596
    [TBL] [Abstract][Full Text] [Related]  

  • 2. ["Laryngeal Tube-D" (LT-D) and "Laryngeal Mask" (LMA)].
    Wiese CH; Bahr J; Graf BM
    Dtsch Med Wochenschr; 2009 Jan; 134(3):69-74. PubMed ID: 19085741
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Reduction in no flow time using a laryngeal tube: comparison to bag-mask ventilation].
    Wiese CH; Bahr J; Bergmann A; Bergmann I; Bartels U; Graf BM
    Anaesthesist; 2008 Jun; 57(6):589-96. PubMed ID: 18338138
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Using a laryngeal tube suction-device (LTS-D) reduces the "no flow time" in a single rescuer manikin study.
    Wiese CH; Bartels U; Schultens A; Steffen T; Torney A; Bahr J; Graf BM
    J Emerg Med; 2011 Aug; 41(2):128-34. PubMed ID: 19217236
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of airway management strategy on "no-flow-time" during an "advanced life support course" for intensive care nurses - a single rescuer resuscitation manikin study.
    Wiese CH; Bartels U; Schultens A; Steffen T; Torney A; Bahr J; Graf BM
    BMC Emerg Med; 2008 Apr; 8():4. PubMed ID: 18402652
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The use of the laryngeal tube disposable by paramedics during out-of-hospital cardiac arrest: a prospectively observational study (2008-2012).
    Müller JU; Semmel T; Stepan R; Seyfried TF; Popov AF; Graf BM; Wiese CH
    Emerg Med J; 2013 Dec; 30(12):1012-6. PubMed ID: 23307754
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparing no-flow time during endotracheal intubation versus placement of a laryngeal mask airway during a simulated cardiac arrest scenario.
    Miller VJ; Flaherty EE
    Simul Healthc; 2014 Jun; 9(3):156-60. PubMed ID: 24310162
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of COVID-19-adapted guidelines using different airway management strategies on resuscitation quality in out-of-hospital-cardiac-arrest - a randomised manikin study.
    Scholz SS; Linder S; Latka E; Bartnick T; Karla D; Thaemel D; Wolff M; Sauzet O; Rehberg SW; Thies KC; Jansen G
    BMC Emerg Med; 2023 May; 23(1):48. PubMed ID: 37189061
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of airway management strategy on "no-flow-time" in a standardized single rescuer manikin scenario (a comparison between LTS-D and I-gel).
    Wiese CH; Bahr J; Popov AF; Hinz JM; Graf BM
    Resuscitation; 2009 Jan; 80(1):100-3. PubMed ID: 18952347
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Supreme Laryngeal Mask Airway achieves faster insertion times than Classic LMA during chest compressions in manikins.
    Chloros T; Xanthos T; Iacovidou N; Bassiakou E
    Am J Emerg Med; 2014 Feb; 32(2):156-9. PubMed ID: 24332907
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Randomized trial of endotracheal tube versus laryngeal mask airway in simulated prehospital pediatric arrest.
    Chen L; Hsiao AL
    Pediatrics; 2008 Aug; 122(2):e294-7. PubMed ID: 18644845
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hands-off time during insertion of six airway devices during cardiopulmonary resuscitation: a randomised manikin trial.
    Ruetzler K; Gruber C; Nabecker S; Wohlfarth P; Priemayr A; Frass M; Kimberger O; Sessler DI; Roessler B
    Resuscitation; 2011 Aug; 82(8):1060-3. PubMed ID: 21514986
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The impact of airway strategy on the patient outcome after out-of-hospital cardiac arrest: A propensity score matched analysis.
    Sulzgruber P; Datler P; Sterz F; Poppe M; Lobmeyr E; Keferböck M; Zeiner S; Nürnberger A; Schober A; Hubner P; Stratil P; Wallmueller C; Weiser C; Warenits AM; Zajicek A; Ettl F; Magnet I; Uray T; Testori C; van Tulder R
    Eur Heart J Acute Cardiovasc Care; 2018 Aug; 7(5):423-431. PubMed ID: 28948850
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility of a laryngeal tube for airway management during cardiac arrest by first responders.
    Länkimäki S; Alahuhta S; Kurola J
    Resuscitation; 2013 Apr; 84(4):446-9. PubMed ID: 22940595
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of six different airway devices regarding regurgitation and pulmonary aspiration during cardio-pulmonary resuscitation (CPR) - A human cadaver pilot study.
    Piegeler T; Roessler B; Goliasch G; Fischer H; Schlaepfer M; Lang S; Ruetzler K
    Resuscitation; 2016 May; 102():70-4. PubMed ID: 26921473
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of the laryngeal tube on the no-flow-time in a simulated two rescuer basic life support setting with inexperienced users.
    Schröder J; Bucher M; Meyer O
    Med Klin Intensivmed Notfmed; 2016 Sep; 111(6):493-500. PubMed ID: 26374339
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of using a laryngeal tube on the no-flow time in a simulated, single-rescuer, basic life support setting with inexperienced users.
    Meyer O; Bucher M; Schröder J
    Anaesthesist; 2016 Mar; 65(3):183-9. PubMed ID: 26886383
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of blind intubation with different supraglottic airway devices by inexperienced physicians in several airway scenarios: a manikin study.
    Bielski A; Smereka J; Madziala M; Golik D; Szarpak L
    Eur J Pediatr; 2019 Jun; 178(6):871-882. PubMed ID: 30903306
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of COVID-19-adapted guidelines on resuscitation quality in out-of-hospital-cardiac-arrest: a manikin study.
    Jansen G; Ebeling N; Latka E; Krüger S; Scholz SS; Trapp S; Grannemann JJ; Thaemel D; Chandwani S; Sauzet O; Rehberg SW; Borgstedt R
    Minerva Anestesiol; 2021 Dec; 87(12):1320-1329. PubMed ID: 34263582
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of blind intubation via supraglottic airway devices versus standard intubation during different airway emergency scenarios in inexperienced hand: Randomized, crossover manikin trial.
    Bielski A; Rivas E; Ruetzler K; Smereka J; Puslecki M; Dabrowski M; Ladny JR; Frass M; Robak O; Evrin T; Szarpak L
    Medicine (Baltimore); 2018 Oct; 97(40):e12593. PubMed ID: 30290627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.