211 related articles for article (PubMed ID: 18507559)
1. Delayed defibrillator lead perforation.
Park RE; Melton IC; Crozier IG
Pacing Clin Electrophysiol; 2008 Jun; 31(6):785-6. PubMed ID: 18507559
[No Abstract] [Full Text] [Related]
2. Asymptomatic right ventricular perforation by an implantable cardioverter defibrillator lead detected by home monitoring system.
Migliore F; Leoni L; Torregrossa G; Guglielmi C; Tarantini G; Buja G; Iliceto S; Corrado D
J Electrocardiol; 2010; 43(6):673-5. PubMed ID: 20888001
[TBL] [Abstract][Full Text] [Related]
3. Delayed cardiac perforation by one small body diameter defibrillator lead.
Haghjoo M; Alizadeh A; Fazelifar AF; Hajahmadi M; Sadr-Ameli MA
J Electrocardiol; 2010; 43(1):71-3. PubMed ID: 19520384
[TBL] [Abstract][Full Text] [Related]
4. Delayed defibrillator lead perforation: an increasing phenomenon.
Satpathy R; Hee T; Esterbrooks D; Mohiuddin S
Pacing Clin Electrophysiol; 2008 Jan; 31(1):10-2. PubMed ID: 18181902
[TBL] [Abstract][Full Text] [Related]
5. Subacute implantable cardioverter defibrillator lead perforation: a potentially life-threatening event.
Tavernier R; Duytschaever M; Dossche K; Verleyen D; Van Den Brande F; De Greef Y; Vandekerckhove Y
Europace; 2009 Jul; 11(7):966-7. PubMed ID: 19406850
[TBL] [Abstract][Full Text] [Related]
6. Successful management of a late right ventricular and diaphragmatic perforation by a defibrillator lead.
Fuenmayor A AJ; Rodríguez S YA
Europace; 2014 Jun; 16(6):886. PubMed ID: 24008496
[No Abstract] [Full Text] [Related]
7. Delayed cardiac perforation by defibrillator lead placed in the right ventricular outflow tract resulting in massive pericardial effusion.
Lau EW; Shannon HJ; McKavanagh P
Pacing Clin Electrophysiol; 2008 Dec; 31(12):1646-9. PubMed ID: 19067821
[TBL] [Abstract][Full Text] [Related]
8. Inappropriate ICD discharges due to noise oversensing as the first sign of repetitive perforations of the right ventricular lead.
Ueda-Tatsumoto A; Fukamizu S; Nishizaki M; Sakurada H; Hiraoka M
Pacing Clin Electrophysiol; 2009 Nov; 32(11):1481-4. PubMed ID: 19712072
[TBL] [Abstract][Full Text] [Related]
9. Management of traumatic implantable cardioverter defibrillator lead perforation of the right ventricle after car accident: a case report.
Sassone B; Gabrieli L; Boggian G; Pilato E
Europace; 2009 Jul; 11(7):961-2. PubMed ID: 19451098
[TBL] [Abstract][Full Text] [Related]
10. Re: Implantable cardioverter-defibrillator.
Mond HG
Pacing Clin Electrophysiol; 2008 Apr; 31(4):517. PubMed ID: 18373777
[No Abstract] [Full Text] [Related]
11. An unusual presentation of implantable cardioverter-defibrillator lead perforation.
Crusio RH; Greenberg YJ
J Electrocardiol; 2009; 42(3):265-6. PubMed ID: 18976778
[TBL] [Abstract][Full Text] [Related]
12. Very late perforation of an implantable cardioverter defibrillator lead: a case report.
Semmler V; Fichtner S; Lennerz C; Kolb C
Br J Gen Pract; 2014 Feb; 64(619):107-8. PubMed ID: 24567613
[No Abstract] [Full Text] [Related]
13. More late perforations with the Riata defibrillator lead from a high-volume center: an update on the numbers.
Lloyd MS; Shaik MN; Riley M; Langberg JJ
Pacing Clin Electrophysiol; 2008 Jun; 31(6):784-5. PubMed ID: 18507558
[No Abstract] [Full Text] [Related]
14. Lead perforation: incidence in registries.
Carlson MD; Freedman RA; Levine PA
Pacing Clin Electrophysiol; 2008 Jan; 31(1):13-5. PubMed ID: 18181903
[No Abstract] [Full Text] [Related]
15. Right ventricular perforation with an ICD defibrillation lead managed by surgical revision and epicardial leads--case reports.
Krivan L; Kozák M; Vlasínová J; Sepsi M
Pacing Clin Electrophysiol; 2008 Jan; 31(1):3-6. PubMed ID: 18181900
[TBL] [Abstract][Full Text] [Related]
16. Hiccup as a result of late lead perforation: report of two cases and review of the literature.
Celik T; Kose S; Bugan B; Iyisoy A; Akgun V; Cingoz F
Europace; 2009 Jul; 11(7):963-5. PubMed ID: 19359331
[TBL] [Abstract][Full Text] [Related]
17. Inadvertent transarterial insertion of atrial and ventricular defibrillator leads.
Issa ZF; Rumman SS; Mullin JC
J Interv Card Electrophysiol; 2009 Jan; 24(1):63-6. PubMed ID: 19016315
[TBL] [Abstract][Full Text] [Related]
18. Concerns about the Riata ST (St. Jude Medical) ICD lead.
Vlay SC
Pacing Clin Electrophysiol; 2008 Jan; 31(1):1-2. PubMed ID: 18181899
[No Abstract] [Full Text] [Related]
19. Increased incidence of subacute perforation noted with one manufacturer of an implantable cardioverter-defibrillator lead.
Mond HG
Heart Rhythm; 2007 Sep; 4(9):1248; author reply 1248. PubMed ID: 17765632
[No Abstract] [Full Text] [Related]
20. Pacing and implantable cardioverter defibrillator lead perforation as assessed by multiplanar reformatted ECG-gated cardiac computed tomography and clinical correlates.
Pang BJ; Lui EH; Joshi SB; Tacey MA; Alison J; Seneviratne SK; Cameron JD; Mond HG
Pacing Clin Electrophysiol; 2014 May; 37(5):537-45. PubMed ID: 24883448
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]