BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 18528652)

  • 1. Measurement of extent of bone ongrowth and hydroxyapatite absorption in retrieved acetabular cups.
    Chung YY; Kim J; Lim CH; Kim KS; Lee YS
    J Orthop Sci; 2008 May; 13(3):198-201. PubMed ID: 18528652
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bone ingrowth on a smooth-surfaced hydroxyapatite-coated acetabular cup.
    Chung YY; Kim HD; Kim KS
    Int Orthop; 2002; 26(5):283-6. PubMed ID: 12378354
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Absence of Hydroxyapatite Coating on Cementless Acetabular Components Does Not Affect Long-Term Survivorship in Total Hip Arthroplasty.
    Sato T; Nakashima Y; Komiyama K; Yamamoto T; Motomura G; Iwamoto Y
    J Arthroplasty; 2016 Jun; 31(6):1228-1232. PubMed ID: 26730449
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components.
    Coathup MJ; Blackburn J; Goodship AE; Cunningham JL; Smith T; Blunn GW
    Biomaterials; 2005 Jul; 26(19):4161-9. PubMed ID: 15664643
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Survival of hydroxyapatite-coated cups: acetabular screws involve a lower rate of revision surgery due to aseptic loosening.
    Natera L; Valera M; Gómez EM; Ibañez N; Crusi X; Sancho R
    Hip Int; 2017 Mar; 27(2):153-161. PubMed ID: 28165590
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of hydroxyapatite coating of cups used in hip revision arthroplasty.
    Lazarinis S; Kärrholm J; Hailer NP
    Acta Orthop; 2012 Oct; 83(5):427-35. PubMed ID: 22937978
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Superior 11-year survival but higher polyethylene wear of hydroxyapatite-coated Mallory-Head cups.
    Gottliebsen M; Rahbek O; Ottosen PF; Søballe K; Stilling M
    Hip Int; 2012; 22(1):35-40. PubMed ID: 22383319
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hydroxyapatite-coated acetabular components. Histological and histomorphometric analysis of six cups retrieved at autopsy between three and seven years after successful implantation.
    Tonino A; Oosterbos C; Rahmy A; Thèrin M; Doyle C
    J Bone Joint Surg Am; 2001 Jun; 83(6):817-25. PubMed ID: 11407789
    [TBL] [Abstract][Full Text] [Related]  

  • 9. No superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups.
    Valancius K; Søballe K; Nielsen PT; Laursen MB
    Acta Orthop; 2013 Dec; 84(6):544-8. PubMed ID: 24171680
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Eight-year results of hydroxyapatite-coated hip arthroplasty.
    Chang JK; Chen CH; Huang KY; Wang GJ
    J Arthroplasty; 2006 Jun; 21(4):541-6. PubMed ID: 16781407
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Grit-blasted and hydroxyapatite-coated total hip arthroplasty: an 11- to 14-year follow-up study.
    Miyakawa S; Kawamura H; Mishima H; Yasumoto J
    J Orthop Sci; 2004; 9(5):462-7. PubMed ID: 15449121
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The acetabular component in total hip arthroplasty. Evaluation of different fixation principles.
    Thanner J
    Acta Orthop Scand Suppl; 1999 Aug; 286():1-41. PubMed ID: 10572504
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues.
    Capello WN; D'Antonio JA; Manley MT; Feinberg JR
    Clin Orthop Relat Res; 1998 Oct; (355):200-11. PubMed ID: 9917605
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry.
    Paulsen A; Pedersen AB; Johnsen SP; Riis A; Lucht U; Overgaard S
    Acta Orthop; 2007 Oct; 78(5):622-8. PubMed ID: 17966021
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does hydroxyapatite coating of uncemented cups improve long-term survival? An analysis of 28,605 primary total hip arthroplasty procedures from the Nordic Arthroplasty Register Association (NARA).
    Lazarinis S; Mäkelä KT; Eskelinen A; Havelin L; Hallan G; Overgaard S; Pedersen AB; Kärrholm J; Hailer NP
    Osteoarthritis Cartilage; 2017 Dec; 25(12):1980-1987. PubMed ID: 28802851
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years.
    Reikerås O; Gunderson RB
    Arch Orthop Trauma Surg; 2006 Oct; 126(8):503-8. PubMed ID: 16799792
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Results at a minimum of 10 years of follow-up for AMS and PerFix HA-coated cementless total hip arthroplasty: impact of cross-linked polyethylene on implant longevity.
    Nakashima Y; Sato T; Yamamoto T; Motomura G; Ohishi M; Hamai S; Akiyama M; Hirata M; Hara D; Iwamoto Y
    J Orthop Sci; 2013 Nov; 18(6):962-8. PubMed ID: 23963589
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tissue reactions adjacent to well-fixed hydroxyapatite-coated acetabular cups. Histopathology of ten specimens retrieved at reoperation after 0.3 to 5.8 years.
    Røkkum M; Reigstad A; Johansson CB; Albrektsson T
    J Bone Joint Surg Br; 2003 Apr; 85(3):440-7. PubMed ID: 12729126
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High revision rate of hydroxyapatite-coated ABG-I prosthesis.
    Chung YY; Ki SC; So KY; Kim DH; Park KH; Lee YS
    J Orthop Sci; 2009 Sep; 14(5):543-7. PubMed ID: 19802665
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Bony ongrowth on the surface of HA-coated femoral implants: an x-ray analysis].
    Zweymüller KA
    Z Orthop Unfall; 2012 Feb; 150(1):27-31. PubMed ID: 22009584
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.