284 related articles for article (PubMed ID: 18528658)
1. Experimental investigations of the insertion and deformation behavior of press-fit and threaded acetabular cups for total hip replacement.
Fritsche A; Bialek K; Mittelmeier W; Simnacher M; Fethke K; Wree A; Bader R
J Orthop Sci; 2008 May; 13(3):240-7. PubMed ID: 18528658
[TBL] [Abstract][Full Text] [Related]
2. Experimental analysis of insertion torques and forces of threaded and press-fit acetabular cups by means of ex vivo and in vivo measurements.
Vogel D; Rathay A; Teufel S; Ellenrieder M; Zietz C; Sander M; Bader R
Acta Bioeng Biomech; 2017; 19(3):155-163. PubMed ID: 29205219
[TBL] [Abstract][Full Text] [Related]
3. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].
Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R
Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572
[TBL] [Abstract][Full Text] [Related]
4. Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?
von Schulze Pellengahr C; von Engelhardt LV; Wegener B; Müller PE; Fottner A; Weber P; Ackermann O; Lahner M; Teske W
BMC Musculoskelet Disord; 2015 Apr; 16():95. PubMed ID: 25896824
[TBL] [Abstract][Full Text] [Related]
5. The influence of head diameter and wall thickness on deformations of metallic acetabular press-fit cups and UHMWPE liners: a finite element analysis.
Goebel P; Kluess D; Wieding J; Souffrant R; Heyer H; Sander M; Bader R
J Orthop Sci; 2013 Mar; 18(2):264-70. PubMed ID: 23377753
[TBL] [Abstract][Full Text] [Related]
6. Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of follow-up of five years.
Manley MT; Capello WN; D'Antonio JA; Edidin AA; Geesink RG
J Bone Joint Surg Am; 1998 Aug; 80(8):1175-85. PubMed ID: 9730127
[TBL] [Abstract][Full Text] [Related]
7. Deformation of acetabular press-fit cups: Influence of design and surgical factors.
Messer-Hannemann P; Campbell GM; Morlock MM
Clin Biomech (Bristol, Avon); 2019 Oct; 69():96-103. PubMed ID: 31325804
[TBL] [Abstract][Full Text] [Related]
8. Press-fit versus threaded acetabular cups in total hip arthroplasty: Functional and radiological results after five years.
Ellenrieder M; Bader R; Bergschmidt P; Mittelmeier W
Acta Orthop Belg; 2016 Mar; 82(1):60-7. PubMed ID: 26984655
[TBL] [Abstract][Full Text] [Related]
9. A novel method to assess primary stability of press-fit acetabular cups.
Crosnier EA; Keogh PS; Miles AW
Proc Inst Mech Eng H; 2014 Nov; 228(11):1126-34. PubMed ID: 25384445
[TBL] [Abstract][Full Text] [Related]
10. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.
Tabata T; Kaku N; Hara K; Tsumura H
Eur J Orthop Surg Traumatol; 2015 Apr; 25(3):497-502. PubMed ID: 25421640
[TBL] [Abstract][Full Text] [Related]
11. Acetabular strains produced by oversized press fit cups.
Ries MD; Harbaugh M
Clin Orthop Relat Res; 1997 Jan; (334):276-81. PubMed ID: 9005924
[TBL] [Abstract][Full Text] [Related]
12. [Complications with the acetabular cup in the CLS total hip joint endoprosthesis].
Rozkydal Z; Janícek P; Deduch J; Hudecek F
Acta Chir Orthop Traumatol Cech; 2001; 68(2):85-92. PubMed ID: 11706722
[TBL] [Abstract][Full Text] [Related]
13. [The influence of different surface treatments on the primary stability of cementless acetabular cups: an in vitro study].
Schreiner U; Simnacher M; Scheller G; Scharf HP
Biomed Tech (Berl); 2007 Jun; 52(3):243-7. PubMed ID: 17561785
[TBL] [Abstract][Full Text] [Related]
14. Time-dependent Viscoelastic Response of Acetabular Bone and Implant Seating during Dynamic Implantation of Press-fit Cups.
Messer-Hannemann P; Weyer H; Campbell GM; Morlock MM
Med Eng Phys; 2020 Jul; 81():68-76. PubMed ID: 32507677
[TBL] [Abstract][Full Text] [Related]
15. Acetabular component deformation with press-fit fixation.
Squire M; Griffin WL; Mason JB; Peindl RD; Odum S
J Arthroplasty; 2006 Sep; 21(6 Suppl 2):72-7. PubMed ID: 16950065
[TBL] [Abstract][Full Text] [Related]
16. Medium to long-term results with the cementless threaded Acetabular Munich II type cup.
Pellengahr C; Wegener B; Anetzberger H; Maier M; Müller PE; Dürr HR; Schulz C; Troullier H; Kühne L; Refior HJ
Acta Chir Belg; 2004 Aug; 104(4):413-7. PubMed ID: 15469152
[TBL] [Abstract][Full Text] [Related]
17. [Allofit cementless acetabular component: five-year experience].
Hoza P; Pilný J; Kubeš J
Acta Chir Orthop Traumatol Cech; 2013; 80(2):148-54. PubMed ID: 23562260
[TBL] [Abstract][Full Text] [Related]
18. Long-term results of HA coated threaded versus HA coated hemispheric press fit cups: 287 hips followed for 11 to 16 years.
Reikerås O; Gunderson RB
Arch Orthop Trauma Surg; 2006 Oct; 126(8):503-8. PubMed ID: 16799792
[TBL] [Abstract][Full Text] [Related]
19. High migration rate of two types of threaded acetabular cups.
Fink B; Protzen M; Hansen-Algenstaedt N; Berger J; Rüther W
Arch Orthop Trauma Surg; 2004 Jan; 124(1):17-25. PubMed ID: 14586628
[TBL] [Abstract][Full Text] [Related]
20. [Metal-on-metal hip replacement using Metasul cups cemented into Muller reinforcement rings after a mean 5-year (3-8) follow-up: improvement of acetabular fixation by comparing with direct cementation to bone].
Girard J; Herent S; Combes A; Pinoit Y; Soenen M; Laffargue P; Migaud H
Rev Chir Orthop Reparatrice Appar Mot; 2008 Jun; 94(4):346-53. PubMed ID: 18555860
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]