These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 18537030)

  • 1. High-resolution ICP-MS determination of Ti, V, Cr, Co, Ni, and Mo in human blood and urine of patients implanted with a hip or knee prosthesis.
    Sarmiento-González A; Marchante-Gayón JM; Tejerina-Lobo JM; Paz-Jiménez J; Sanz-Medel A
    Anal Bioanal Chem; 2008 Aug; 391(7):2583-9. PubMed ID: 18537030
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cobalt, chromium, and nickel concentrations in body fluids of patients with porous-coated knee or hip prostheses.
    Sunderman FW; Hopfer SM; Swift T; Rezuke WN; Ziebka L; Highman P; Edwards B; Folcik M; Gossling HR
    J Orthop Res; 1989; 7(3):307-15. PubMed ID: 2649648
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The release of metals from metal-on-metal surface arthroplasty of the hip.
    Iavicoli I; Falcone G; Alessandrelli M; Cresti R; De Santis V; Salvatori S; Alimonti A; Carelli G
    J Trace Elem Med Biol; 2006; 20(1):25-31. PubMed ID: 16632173
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Differential distribution of cobalt, chromium, and nickel between whole blood, plasma and urine in patients after metal-on-metal (MoM) hip arthroplasty.
    Newton AW; Ranganath L; Armstrong C; Peter V; Roberts NB
    J Orthop Res; 2012 Oct; 30(10):1640-6. PubMed ID: 22447496
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Concentration of metal elements in the blood and urine in the patients with cementless total knee arthroplasty.
    Liu TK; Liu SH; Chang CH; Yang RS
    Tohoku J Exp Med; 1998 Aug; 185(4):253-62. PubMed ID: 9865472
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Metal ion levels after metal-on-metal proximal femoral replacements: a 30-year follow-up.
    Dunstan E; Sanghrajka AP; Tilley S; Unwin P; Blunn G; Cannon SR; Briggs TW
    J Bone Joint Surg Br; 2005 May; 87(5):628-31. PubMed ID: 15855362
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Potential presence of metals in patients treated with metal-metal coupling prostheses for hip arthroplasty at 7 and 10 years of follow-up.
    Sessa G; Testa G; Gioitta Iachino S; Costarella L; Puma Pagliarello C; Ferrante M; Grasso A; Pavone V
    Eur J Orthop Surg Traumatol; 2018 May; 28(4):637-643. PubMed ID: 29356908
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of trace amounts of cadmium, cobalt, chromium, iron, molybdenum, nickel, selenium, titanium, vanadium and zinc in blood and milk by neutron activation analysis.
    Lavi N; Alfassi ZB
    Analyst; 1990 Jun; 115(6):817-22. PubMed ID: 2393086
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Vanadium release in whole blood, serum and urine of patients implanted with a titanium alloy hip prosthesis.
    Catalani S; Stea S; Beraudi A; Gilberti ME; Bordini B; Toni A; Apostoli P
    Clin Toxicol (Phila); 2013 Aug; 51(7):550-6. PubMed ID: 23845123
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Nickel-, chrom- and cobalt-concentrations in human tissue and body fluids of hip prosthesis patients.
    Hennig FF; Raithel HJ; Schaller KH; Döhler JR
    J Trace Elem Electrolytes Health Dis; 1992 Dec; 6(4):239-43. PubMed ID: 1304233
    [TBL] [Abstract][Full Text] [Related]  

  • 11. TEM observation of seven retrieved total knee joints made of Co-Cr-Mo and Ti-Al-V alloys.
    Ichinose S; Muneta T; Aoki H; Tagami M
    Biomed Mater Eng; 2003; 13(2):125-34. PubMed ID: 12775903
    [TBL] [Abstract][Full Text] [Related]  

  • 12. ICP-MS multielemental determination of metals potentially released from dental implants and articular prostheses in human biological fluids.
    Sarmiento-González A; Marchante-Gayón JM; Tejerina-Lobo JM; Paz-Jiménez J; Sanz-Medel A
    Anal Bioanal Chem; 2005 Jun; 382(4):1001-9. PubMed ID: 15877222
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the method for analyzing chromium, cobalt and titanium ion levels in the blood following hip replacement with a metal-on-metal prosthesis.
    Barry J; Lavigne M; Vendittoli PA
    J Anal Toxicol; 2013 Mar; 37(2):90-6. PubMed ID: 23276726
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative in vivo biocompatibility of new ultralow-nickel cobalt-chromium-molybdenum alloys.
    Sonofuchi K; Hagiwara Y; Koizumi Y; Chiba A; Kawano M; Nakayama M; Ogasawara K; Yabe Y; Itoi E
    J Orthop Res; 2016 Sep; 34(9):1505-13. PubMed ID: 26744180
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of different bearing surfaces on metal ion levels in urine following 28 mm metal-on-metal and 28 mm metal-on-polyethylene total hip arthroplasty.
    Tiusanen H; Mäkelä K; Kiilunen M; Sarantsin P; Sipola E; Pesola M
    Scand J Surg; 2013; 102(3):197-203. PubMed ID: 23963035
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The study of metal ion release and cytotoxicity in Co-Cr-Mo and Ti-Al-V alloy in total knee prosthesis - scanning electron microscopic observation.
    Ichinose S; Muneta T; Sekiya I; Itoh S; Aoki H; Tagami M
    J Mater Sci Mater Med; 2003 Jan; 14(1):79-86. PubMed ID: 15348542
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metallic ion release after knee prosthesis implantation: a prospective study.
    Lons A; Putman S; Pasquier G; Migaud H; Drumez E; Girard J
    Int Orthop; 2017 Dec; 41(12):2503-2508. PubMed ID: 28616704
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Thermo-responsive polymer coated fiber-in-tube capillary microextraction and its application to on-line determination of Co, Ni and Cd by inductively coupled plasma mass spectrometry (ICP-MS).
    Zheng F; Hu B
    Talanta; 2011 Aug; 85(2):1166-73. PubMed ID: 21726754
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.
    Vendittoli PA; Roy A; Mottard S; Girard J; Lusignan D; Lavigne M
    J Bone Joint Surg Br; 2010 Jan; 92(1):12-9. PubMed ID: 20044673
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Levels of Cr, Co, Ni and Mo in erythrocytes, serum and urine after hip resurfacing arthroplasty.
    Mazoochian F; Schmidutz F; Kiefl J; Fottner A; Michalke B; Schierl R; Thomas P; Jansson V
    Acta Chir Belg; 2013; 113(2):123-8. PubMed ID: 23741931
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.